High-speed cineradiography using electronic imaging
Abstract
The Los Alamos National Laboratory has constructed and is now operating a cineradiography system for imaging and evaluation of ballistic interaction events at the 1200 meter range of the Terminal Effects Research and Analysis (TERA) Group at the New Mexico Institute of Mining and Technology. Cineradiography is part of a complete firing, tracking, and analysis system at the range. The cine system consists of flash x-ray sources illuminating a one-half meter by two meter fast phosphor screen which is viewed by gated-intensified high resolution still video cameras via turning mirrors. The entire system is armored to protect against events containing up to 13.5 kg of high explosive. Digital images are available for immediate display and processing. The system is capable of frame rates up to 10<SUP>5</SUP>/sec for up to five total images.
BibTeX
@inproceedings{lucero1993high,
author = {Jacob P. Lucero and David A. Fry and William E. Gaskill and Rolland Henderson and Ted R. Crawford and Nicole Carey},
title = {{High-speed cineradiography using electronic imaging}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {1993},
doi = {10.1117/12.145814},
}Ask Althea to put this paper to the test.