High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil
Abstract
This paper reports on the characterization of a palladium (Pd)-based fiber-optic hydrogen (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) sensor for health monitoring of distribution and power transformers in the electrical grid. The sensor consists of a Pd foil, which expands due to H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> absorption, and a fiber Bragg grating that measures this expansion. Fifteen sensors were manufactured and characterized in gas and oil environments at various H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentrations and temperatures. In gas, the sensors were evaluated at 60 °C, 75 °C, 90 °C, 105 °C, and 120 °C and H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentrations from 0.01% to 5%. In oil, the same sensors were evaluated at 90 °C and dissolved H2 concentrations from 5 to 2700 ppm. Furthermore, the influence of carbon monoxide (CO), which is often present in transformers and can impact H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> response of the sensor, was investigated. At 90 °C in gas, the response to 0.01% and 5% H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> was on average 28 and 719 pm, respectively. At 90 °C in oil, the response to 5 and 2700 ppm dissolved H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> was on average 11 and 763 pm, respectively. The average, relative accuracy is better than 20% over the whole measurement range in gas and for measurements above 100 ppm in oil. These specifications make the sensor a promising candidate for online monitoring of H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> in transformers.
BibTeX
@article{fisser2019high,
author = {Maximilian Fisser and Rodney A. Badcock and Paul D. Teal and Arvid Hunze},
title = {{High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil}},
journal = {IEEE Sensors Journal},
year = {2019},
doi = {10.1109/jsen.2019.2891523},
}Ask Althea to put this paper to the test.
Loading related content...