High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil

Maximilian Fisser, Rodney A. Badcock, Paul D. Teal, Arvid HunzeIEEE Sensors Journal 2019

Abstract

This paper reports on the characterization of a palladium (Pd)-based fiber-optic hydrogen (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) sensor for health monitoring of distribution and power transformers in the electrical grid. The sensor consists of a Pd foil, which expands due to H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> absorption, and a fiber Bragg grating that measures this expansion. Fifteen sensors were manufactured and characterized in gas and oil environments at various H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentrations and temperatures. In gas, the sensors were evaluated at 60 °C, 75 °C, 90 °C, 105 °C, and 120 °C and H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentrations from 0.01% to 5%. In oil, the same sensors were evaluated at 90 °C and dissolved H2 concentrations from 5 to 2700 ppm. Furthermore, the influence of carbon monoxide (CO), which is often present in transformers and can impact H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> response of the sensor, was investigated. At 90 °C in gas, the response to 0.01% and 5% H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> was on average 28 and 719 pm, respectively. At 90 °C in oil, the response to 5 and 2700 ppm dissolved H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> was on average 11 and 763 pm, respectively. The average, relative accuracy is better than 20% over the whole measurement range in gas and for measurements above 100 ppm in oil. These specifications make the sensor a promising candidate for online monitoring of H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> in transformers.
BibTeX
@article{fisser2019high,
  author = {Maximilian Fisser and Rodney A. Badcock and Paul D. Teal and Arvid Hunze},
  title = {{High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil}},
  journal = {IEEE Sensors Journal},
  year = {2019},
  doi = {10.1109/jsen.2019.2891523},
}

Loading related content...

Figure