High Sensitivity and High Stability QCM Humidity Sensors Based on Polydopamine Coated Cellulose Nanocrystals/Graphene Oxide Nanocomposite

Yao Yao, Xianhe Huang, Qiao Chen, Zheng Zhang, Weiwei LingNanomaterials 2020 · DOI

TL;DR

Researchers have developed a novel humidity sensor using a polydopamine-coated cellulose nanocrystal/graphene oxide (PDA@CNC/GO) nanocomposite. This new material significantly boosts sensitivity and maintains excellent stability across a wide humidity range, addressing a key challenge in current sensor technology.

What Problem Does This Paper Address?

Accurate and reliable humidity sensing is crucial for various applications, from industrial process control to weather forecasting and the burgeoning Internet of Things (IoT). While Quartz Crystal Microbalance (QCM) sensors offer high sensitivity and real-time monitoring, existing materials often struggle to balance high sensitivity with long-term stability, particularly at high humidity levels. Many materials that enhance sensitivity by increasing water molecule adsorption can lead to abnormal frequency shifts and reduced stability due to viscoelastic changes. This paper aims to overcome this trade-off by developing a nanocomposite material that offers both superior sensitivity and robust stability.

Methods

The core of this research lies in the development and characterization of a novel sensing material: a polydopamine (PDA) coated cellulose nanocrystal (CNC) integrated with graphene oxide (GO).

  • Material Synthesis:
    • Graphene oxide (GO) was synthesized using a modified Hummers method.
  • Cellulose nanocrystals (CNC) were prepared via sulfuric acid hydrolysis of microcrystal cellulose.
  • PDA@CNC was created through the self-polymerization of dopamine onto the surface of CNC.
  • The final PDA@CNC/GO nanocomposite was formed by dispersing PDA@CNC into a GO suspension, followed by ultrasonic treatment. Different weight percentages of PDA@CNC were explored (e.g., PDA@CNC/GO30, indicating 30% PDA@CNC by weight).
  • Sensor Fabrication:
    • Standard 10 MHz AT-cut QCM crystals were used.
  • The sensitive films (GO, CNC/GO30, and PDA@CNC/GO30) were deposited onto the QCM electrodes by applying a small volume of their respective suspensions.
  • The fabricated sensors were then dried to evaporate water.
  • Characterization:
    • Transmission Electron Microscopy (TEM): Used to visualize the morphology and layered structure of the GO, CNC/GO30, and PDA@CNC/GO30 nanocomposites, confirming the contact of CNC and PDA@CNC with GO sheets.
  • Fourier Transform Infrared Spectroscopy (FTIR): Employed to analyze the chemical composition and confirm the successful attachment of CNC and PDA@CNC to GO through hydrogen bonding.
  • Humidity Sensing Measurement:
    • A homemade humidity sensing platform was utilized, incorporating a humidity generation unit (using saturated salt solutions to create specific humidity levels from 11.3% to 97.3% RH), a phase-locked loop oscillator to drive the QCM, a frequency counter, and a digital multimeter connected to a PC for data acquisition.
  • Key performance metrics evaluated included:
  • Frequency Shift: The change in QCM resonance frequency as a function of relative humidity (RH).
  • Sensitivity: Calculated as the ratio of frequency shift (Δf) to humidity change (ΔRH).
  • Dynamic Resistance: Measured to assess sensor stability, as it's inversely proportional to the QCM's quality factor.
  • Humidity Hysteresis: The difference in sensor response during adsorption (increasing humidity) and desorption (decreasing humidity).
  • Response and Recovery Times: The time taken for the sensor to reach 90% of its total frequency shift upon a change in humidity.
  • Long-Term Stability: Monitored over three weeks at different humidity points.

Datasets

Not discussed in the paper. The experiments were conducted using controlled humidity levels generated by saturated salt solutions.

Key Insights and Ideas

  • Synergistic Effect of PDA@CNC and GO: The combination of PDA@CNC and GO creates a nanocomposite that significantly outperforms pristine GO and CNC/GO in terms of humidity sensing. PDA@CNC acts as a crucial filler material.
  • Enhanced Adsorption Sites: The hydrophilic functional groups in PDA@CNC provide more sites for water molecule adsorption, directly boosting sensor sensitivity.
  • Inhibition of Swelling: A critical finding is that PDA@CNC effectively inhibits the swelling of GO-based nanocomposites when exposed to high humidity. This is attributed to the strong adhesive force provided by PDA, which binds GO lamellae tightly and prevents dramatic interlayer expansion. This is key to maintaining stability.
  • Balancing Sensitivity and Stability: The research highlights that simply increasing adsorption sites (like with CNC alone) can lead to instability. PDA@CNC offers a dual benefit: increasing adsorption sites and preventing detrimental swelling, thus achieving both high sensitivity and high stability.
  • Optimized PDA@CNC Content: The study found that increasing PDA@CNC content generally improves sensitivity, but beyond a certain point (e.g., 50%), it can lead to increased dynamic resistance and reduced stability due to increased viscosity. PDA@CNC/GO30 was identified as an optimal composition.

Key Results

  • Superior Sensitivity: The PDA@CNC/GO30-coated QCM sensor achieved a remarkable sensitivity of 54.66 Hz/% RH, which is approximately twice that of the GO-coated sensor (26.5 Hz/% RH) and significantly higher than the CNC/GO30 sensor (37.08 Hz/% RH).
  • Exceptional Stability: The dynamic resistance of the PDA@CNC/GO30 sensor showed minimal fluctuations (13.77–15.7 Ω) across the entire humidity range (11.3–97.3% RH), with a change rate of only 14%. This is a substantial improvement over CNC/GO30 (97.4% change) and GO (38% change) sensors, especially at high humidity.
  • Low Humidity Hysteresis: The PDA@CNC/GO30 sensor exhibited a low humidity hysteresis rate of 4.3%, comparable to other GO nanocomposite sensors, indicating good reliability.
  • Fast Response/Recovery: Response and recovery times were measured at 37/5 seconds for the 48% to 97.3% RH range, demonstrating a good dynamic performance.
  • Long-Term Stability: The sensor maintained prominent long-term stability, with frequency fluctuations less than 6% over three weeks at different humidity points.

Limitations and Future Work

  • Response Time at High Humidity: While the response and recovery are generally fast, the response time for PDA@CNC/GO30 is slightly longer than for pristine GO, particularly at high humidity. The authors note that this is an inherent trade-off when introducing filler materials.
  • Optimization of PDA@CNC Content: The study identified PDA@CNC/GO30 as optimal, but further fine-tuning of the PDA@CNC content could potentially yield even better performance.
  • Mechanism of Swelling Inhibition: While the paper attributes the stability to PDA inhibiting GO swelling, further detailed investigations into the precise molecular interactions and structural changes could provide deeper insights.
  • Practical Applications: The paper suggests that this nanocomposite is a promising candidate for high-sensitivity and high-stability QCM humidity sensors. Future work could focus on integrating these sensors into practical devices and testing them in real-world environmental conditions.

Summary updated

Abstract

In this paper, a high sensitivity and high stability quartz crystal microbalance (QCM) humidity sensor using polydopamine (PDA) coated cellulose nanocrystal (CNC)/graphene oxide (GO) (PDA@CNC/GO) nanocomposite as sensitive material is demonstrated. The PDA@CNC was prepared by the self-polymerization action on the surface of CNC, and it acted as filler material to form functional nanocomposite with GO. The material characteristics of PDA@CNC, CNC/GO and PDA@CNC/GO were analyzed by transmission electron microscope (TEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The experimental results show that the introduction of PDA@CNC into GO film not only effectively enhanced the sensitivity of GO-based nanocomposite-coated QCM sensor but also significantly maintained high stability in the entire humidity range. The PDA@CNC/GO30-coated QCM humidity sensor exhibited a superior response sensitivity up to 54.66 Hz/% relative humidity (RH), while the change rate of dynamic resistance of the sensor in the humidity range of 11.3-97.3% RH is only 14% that is much smaller than that of CNC/GO-coated QCM. Besides, the effect of the PDA@CNC content on the sensitivity and stability of GO-based nanocomposite-coated QCM humidity was also studied. Moreover, other performances of PDA@CNC/GO-coated QCM humidity sensor, including humidity hysteresis, fast response and recovery and long-term stability, were systematically investigated. This work suggests that PDA@CNC/GO nanocomposite is a promising candidate material for realizing high sensitivity and high stability QCM humidity sensor in the entire humidity detection range.
BibTeX
@inproceedings{yao2020high,
  author = {Yao Yao and Xianhe Huang and Qiao Chen and Zheng Zhang and Weiwei Ling},
  title = {{High Sensitivity and High Stability QCM Humidity Sensors Based on Polydopamine Coated Cellulose Nanocrystals/Graphene Oxide Nanocomposite}},
  booktitle = {Nanomaterials},
  year = {2020},
  doi = {10.3390/nano10112210},
}
Figure