High-resolution relaxometry-based calibrated fMRI in murine brain: Metabolic differences between awake and anesthetized states
Lists
Only you see this
Abstract
Functional magnetic resonance imaging (fMRI) techniques using the blood-oxygen level-dependent (BOLD) signal have shown great potential as clinical biomarkers of disease. Thus, using these techniques in preclinical rodent models is an urgent need. Calibrated fMRI is a promising technique that can provide high-resolution mapping of cerebral oxygen metabolism (CMR<sub>O2</sub>). However, calibrated fMRI is difficult to use in rodent models for several reasons: rodents are anesthetized, stimulation-induced changes are small, and gas challenges induce noisy CMR<sub>O2</sub> predictions. We used, in mice, a relaxometry-based calibrated fMRI method which uses cerebral blood flow (CBF) and the BOLD-sensitive magnetic relaxation component, R<sub>2</sub>', the same parameter derived in the deoxyhemoglobin-dilution model of calibrated fMRI. This method does not use any gas challenges, which we tested on mice in both awake and anesthetized states. As anesthesia induces a whole-brain change, our protocol allowed us to overcome the former limitations of rodent studies using calibrated fMRI. We revealed 1.5-2 times higher CMR<sub>O2</sub>, dependent upon brain region, in the awake state versus the anesthetized state. Our results agree with alternative measurements of whole-brain CMR<sub>O2</sub> in the same mice and previous human anesthesia studies. The use of calibrated fMRI in rodents has much potential for preclinical fMRI.
BibTeX
@article{xu2021high,
author = {Mengyang Xu and Binshi Bo and Mengchao Pei and Yuyan Chen and Christina Shu and Qikai Qin and Lydiane Hirschler and Jan Warnking and Emmanuel Barbier and Zhiliang Wei and Hanzhang Lu and Péter Hermán and Fahmeed Hyder and Zhi‐Jie Liu and Zhifeng Liang and Garth J. Thompson},
title = {{High-resolution relaxometry-based calibrated fMRI in murine brain: Metabolic differences between awake and anesthetized states}},
journal = {Journal of Cerebral Blood Flow \& Metabolism},
year = {2021},
doi = {10.1177/0271678x211062279},
}Loading related content...