High precision localization of pulmonary nodules on chest CT utilizing axial slice number labels

Yeshwant Reddy Chillakuru, Kyle Kranen, Vishnu Doppalapudi, Zhangyuan Xiong, Letian Fu, Aarash Heydari, Aditya Sheth, Youngho Seo, Thienkhai Vu, Jae Ho SohnBMC Medical Imaging 2021 · DOI

Abstract

Lung cancer screening requires longitudinal tracking of pulmonary nodules, a task often hindered by the high false-positive rates of traditional Computer-Aided Detection (CAD) systems. This study presents a high-precision deep learning pipeline that leverages axial slice numbers from prior radiology reports to re-locate nodules. By incorporating these "hints" into a multi-stage detection and filtering process, the system achieves a precision of 0.962 with a remarkably low false-positive rate of 0.04 per scan, offering a significant improvement for clinical follow-up workflows.

Introduction

The efficacy of lung cancer screening programs depends on the accurate monitoring of pulmonary nodules over time. Radiologists must manually identify and compare tiny lesions across multiple scans, a process that is both time-consuming and prone to error. While CAD systems aim to assist this process, many suffer from excessive false positives, which can lead to "alarm fatigue" and reduced clinical utility. This research focuses on developing a high-precision detector specifically designed to assist in the re-identification of known nodules by utilizing existing metadata in radiology reports.

Methodology

The proposed pipeline consists of five distinct stages designed to maximize precision:

  1. Preprocessing with Maximum Intensity Projection (MIP): CT scans are processed into 25mm thick slabs. MIP enhances the visibility of spherical nodules while differentiating them from linear vascular structures.
  2. 2D Detection: A RetinaNet architecture with a ResNet-101 backbone is employed to identify potential nodules within the 2D MIP slices.
  3. 3D Clustering: To account for the 3D nature of nodules across multiple slices, the DBSCAN algorithm groups 2D detections into 3D candidate clusters.
  4. False Positive Reduction: An XGBoost classifier, trained on cluster-specific metadata such as confidence scores and multi-view consistency (axial and coronal), filters out erroneous detections.
  5. Axial-Slice Assisted Selection: The final stage utilizes the axial slice number from previous radiology reports. The system selects the candidate nodule closest to the reported position within a 10–20mm vertical window.

Data and Evaluation

The model was developed and tested using two primary datasets: the Lung Nodule Analysis 2016 (LUNA) dataset and the National Lung Screening Trial (NLST) dataset.

Selection process for the training and validation sets from the LUNA dataset.

The training phase utilized 888 CT scans from the LUNA dataset, partitioned into training (n=755) and validation (n=133) sets as shown above.

Selection process for the test set from the NLST dataset.

Evaluation was conducted on a test set of 47 CT scans from the NLST dataset containing 89 nodules. A separate non-overlapping set of 93 NLST scans was used to train the XGBoost false-positive reduction component.

Results and Discussion

The pipeline demonstrated exceptional performance in precision, reaching 0.962 at a recall of 0.573. Most notably, the system produced only 0.04 false positives per scan, a substantial reduction compared to commercial CAD systems which often range from 0.62 to over 70 false positives per scan.

Analysis of nodule types revealed that the model is highly effective for soft tissue nodules (94% accuracy) but struggles with ground glass opacities (2% accuracy). This discrepancy highlights the difficulty of detecting faint, hazy lesions compared to solid nodules. Furthermore, the model's success across scans from 33 different institutions in the NLST dataset indicates strong generalization capabilities across various CT hardware.

Conclusion

By leveraging previously ignored "quasi-ground truth" labels in radiology reports, this study demonstrates that a high-precision approach can significantly streamline the nodule tracking process. While the current recall of ~57% limits its use as a standalone detection tool, its near-perfect precision makes it an ideal assistant for radiologists during follow-up screenings. Future work will focus on improving recall for subpleural and ground glass nodules and exploring the use of this high-precision tool for automated large-scale dataset labeling.

Summary updated

Abstract

Background Reidentification of prior nodules for temporal comparison is an important but time-consuming step in lung cancer screening. We develop and evaluate an automated nodule detector that utilizes the axial-slice number of nodules found in radiology reports to generate high precision nodule predictions. Methods 888 CTs from Lung Nodule Analysis were used to train a 2-dimensional (2D) object detection neural network. A pipeline of 2D object detection, 3D unsupervised clustering, false positive reduction, and axial-slice numbers were used to generate nodule candidates. 47 CTs from the National Lung Cancer Screening Trial (NLST) were used for model evaluation. Results Our nodule detector achieved a precision of 0.962 at a recall of 0.573 on the NLST test set for any nodule. When adjusting for unintended nodule predictions, we achieved a precision of 0.931 at a recall 0.561, which corresponds to 0.06 false positives per CT. Error analysis revealed better detection of nodules with soft tissue attenuation compared to ground glass and undeterminable attenuation. Nodule margins, size, location, and patient demographics did not differ between correct and incorrect predictions. Conclusions Utilization of axial-slice numbers from radiology reports allowed for development of a lung nodule detector with a low false positive rate compared to prior feature-engineering and machine learning approaches. This high precision nodule detector can reduce time spent on reidentification of prior nodules during lung cancer screening and can rapidly develop new institutional datasets to explore novel applications of computer vision in lung cancer imaging.