Abstract
Traditional image contrast enhancement methods often fail to improve the quality of vein images and may introduce unknown noise, leading to low recognition rates. This paper proposes an enhancement method based on morphological filtering theory consisting of three main procedures. First, the algorithm extracts the vein Region of Interest (ROI) and utilizes improved White Top-Hat (WTH) and Black Top-Hat (BTH) transforms to extract detailed vein and background features. Second, a filtering function with a self-designed controlling operator is constructed to represent vein edge gradients, reflecting local detail importance in a multi-scale pattern. Finally, a modified non-linear gray-level transformation realizes gray normalization. Experimental results on a self-built dorsal vein database demonstrate that the proposed multi-scale top-hat method significantly improves contrast while suppressing noise.
Introduction
Hand vein recognition is a robust biometric technique due to the internal nature of vein patterns, which makes them difficult to forge. Captured using near-infrared (NIR) light, veins appear as dark patterns because hemoglobin absorbs NIR radiation. However, raw images often suffer from low contrast and noise due to variations in lighting and skin thickness. Traditional techniques like Histogram Equalization (HE) often amplify "salt and pepper" noise alongside the signal. This research addresses these challenges by developing a multi-scale morphological approach that enhances specific vein textures while suppressing background interference.
Methodology
The proposed pipeline follows a structured morphological approach to isolate and enhance vein structures.
1. ROI Extraction and Pre-processing
The algorithm identifies the Region of Interest (ROI) by applying median filtering for denoising and Sobel operators for edge detection. Geometric corrections are applied to handle hand rotation, resulting in a standardized 180×180 pixel sub-image.
2. Multi-Scale Top-Hat Transform
Mathematical morphology is used to extract features smaller than a specific structural element.
- White Top-Hat (WTH): Extracts bright background features.
- Black Top-Hat (BTH): Extracts dark vein features. By employing multiple scales, the algorithm captures both fine capillaries and larger vessels.
3. Edge Gradient Control and Normalization
To prevent over-enhancement of flat, noisy areas, a self-designed controlling operator ($\delta_i$) based on a sigmoid function is introduced. This operator ensures contrast is only boosted where clear edges (vein boundaries) exist. Finally, a piecewise quadratic function and standard normalization adjust the global gray levels to the full 0–255 range.
Results and Discussion
The method was evaluated using a self-built database of 500 dorsal vein images. Quantitative analysis compared the proposed method against Histogram Equalization (HE) and Traditional Morphological Filtering (TMF).
| Metric | HE | TMF | Proposed Method |
|---|---|---|---|
| Information Entropy (IE) | 2.56 | - | 3.85 |
| PSNR (dB) | 10.34 | 16.52 | 21.54 |
| Sharpness (PN) | 25.85 | - | 51.29 |
The proposed method achieved a significantly higher PSNR, indicating superior noise suppression. The Information Entropy and Sharpness scores further validate the richness of detail and clarity in the enhanced images.
The algorithm is computationally efficient, with an average processing time of 0.61 seconds, making it suitable for real-time embedded biometric systems.
Conclusion
The multi-scale top-hat transform effectively balances detail enhancement and noise suppression in hand vein biometrics. Future work will focus on automating parameter selection and exploring unsupervised learning techniques, such as CNNs, to adapt the algorithm to diverse skin types and lighting conditions automatically.