H∞ Robust Control of a Large-Piston MEMS Micromirror for Compact Fourier Transform Spectrometer Systems

Huipeng Chen, Mengyuan Li, Yi Zhang, Huikai Xie, Chang Chen, Zhangming Peng, Shaohui SuSensors 2018 · DOI

TL;DR

This paper tackles the challenge of precise mirror control in miniaturized Fourier Transform Spectrometers (FTS) by developing an H∞ robust control system for a large-displacement MEMS micromirror. The H∞ controller significantly reduces mirror tilting during scanning, leading to a substantial improvement in spectral resolution and robustness compared to PID and open-loop methods.

What Problem Does This Paper Address?

Fourier Transform Infrared Spectroscopy (FTIR) is a powerful analytical technique, but traditional FTS systems are bulky and expensive. Miniaturizing FTS using Micro-Electro-Mechanical Systems (MEMS) micromirrors offers the promise of portable devices for field analysis. However, a critical hurdle is controlling the precise tilting of the MEMS mirror during its large linear scan. Even small tilts can severely degrade the interferogram, leading to low spectral resolution or unusable spectra. Existing control methods struggle with the inherent coupling between mirror axes and are sensitive to environmental changes and component aging.

Methods

The researchers developed a biaxial H∞ robust controller for a MEMS micromirror designed for large piston displacement (180 µm). The core of their approach involves:

  • System Identification: They experimentally determined the dynamic models (transfer functions) for the micromirror's x and y axes using frequency response measurements.
  • H∞ Mixed Sensitivity Design: This advanced control technique was employed to design a controller that simultaneously minimizes sensitivity (tracking error) and complementary sensitivity (disturbance rejection) while accounting for system uncertainties. This involves carefully selecting weighting functions to shape the closed-loop frequency response.
  • Comparison with Baseline Controllers: The performance of the H∞ controller was benchmarked against a Proportional-Integral-Derivative (PID) controller and a look-up table controller, both of which are simpler to implement but less robust.

Datasets

Not discussed in the paper. The paper focuses on experimental validation using a custom-built MEMS FTS system.

Key Insights and Ideas

  • Tilting is the Achilles' Heel: The paper strongly emphasizes that mirror tilting, not just piston displacement, is the primary limiting factor for achieving high-resolution spectra in MEMS-based FTS.
  • H∞ for Robustness: The H∞ control framework proves highly effective in achieving both precise tilt control and robustness against external disturbances and potential parameter variations (like aging). This is a significant advantage over simpler controllers.
  • Biaxial Control is Crucial: Using a biaxial controller that manages both x and y axes simultaneously is key to preventing uncontrolled instability in one axis from affecting the other.
  • Trade-offs in Control: While PID and look-up table methods are easier to implement, their performance degrades significantly under varying conditions, highlighting the need for more advanced robust control strategies for demanding applications.

Key Results

  • Reduced Tilting: The H∞ robust controller reduced the residual tilting angle to an impressive ±0.0014° over the full scanning range. This is a dramatic improvement compared to PID (±0.0026°/±0.003°) and look-up table (±0.008°) control, and vastly better than the uncontrolled case.
  • Improved Spectral Resolution: The FTS system equipped with the H∞ controller achieved a spectral resolution of 96 cm⁻¹ (2.71 nm at 532.2 nm), a significant enhancement over the PID control (150 cm⁻¹) and look-up table control (210 cm⁻¹).
  • Robustness Demonstrated: The H∞ controller maintained excellent performance even when the drive signal frequency was varied, showcasing its robustness.
  • Stable Scanning Displacement: A stable scanning displacement of 110.9 µm was achieved under H∞ control.

Limitations and Future Work

  • Thermal Response Time: The current LSF bimorph-based MEMS mirror has a relatively slow thermal response time (~100 ms), which limits the scanning speed.
  • Future Work: The authors plan to focus on designing and fabricating a large-stroke electrothermal micromirror with a faster thermal response to overcome this speed limitation. They also suggest future work could explore further optimization of the control system and potentially investigate the impact of increased AC amplitude on the transfer function.

Summary updated

Abstract

Incorporating linear-scanning micro-electro-mechanical systems (MEMS) micromirrors into Fourier transform spectral acquisition systems can greatly reduce the size of the spectrometer equipment, making portable Fourier transform spectrometers (FTS) possible. How to minimize the tilting of the MEMS mirror plate during its large linear scan is a major problem in this application. In this work, an FTS system has been constructed based on a biaxial MEMS micromirror with a large-piston displacement of 180 μm, and a biaxial H∞ robust controller is designed. Compared with open-loop control and proportional-integral-derivative (PID) closed-loop control, H∞ robust control has good stability and robustness. The experimental results show that the stable scanning displacement reaches 110.9 μm under the H∞ robust control, and the tilting angle of the MEMS mirror plate in that full scanning range falls within ±0.0014°. Without control, the FTS system cannot generate meaningful spectra. In contrast, the FTS yields a clean spectrum with a full width at half maximum (FWHM) spectral linewidth of 96 cm<sup>-1</sup> under the H∞ robust control. Moreover, the FTS system can maintain good stability and robustness under various driving conditions.
BibTeX
@inproceedings{chen2018h,
  author = {Huipeng Chen and Mengyuan Li and Yi Zhang and Huikai Xie and Chang Chen and Zhangming Peng and Shaohui Su},
  title = {{H∞ Robust Control of a Large-Piston MEMS Micromirror for Compact Fourier Transform Spectrometer Systems}},
  booktitle = {Sensors},
  year = {2018},
  doi = {10.3390/s18020508},
}
Figure