Abstract: Accurate extraction of liquid is the first step towards low-volume liquid delivery and nanocharacterization, which plays a significant role in biomedical research. In this study, a tip-shaped graphene nanopipette (GNP) is proposed by encapsulating the biomolecule solution on the prefabricated metal tip with graphene. The volume of the encapsulated liquid is highly controllable at zeptoliter precision by tuning the encapsulating speed and the number of graphene encapsulation rounds. Using protein (ferritin) solution as an example, it has been confirmed by finite element analysis and the controlled experiments that the GNP allows the delivery of ferritin solution at the zeptoliter-scale. Furthermore, GNP is demonstrated as a new type of tip-shaped liquid cell, which is suitable for multiple nanocharacterization techniques. In particular, due to the ultra-sharp tip shape, isotope (13C)-labelled glucose solution encapsulated in GNP has been characterized by atom probe tomography (APT) in the laser-pulsed mode. Analysis of the mass spectrum and the reconstructed three-dimensional chemical maps reveals the quantitative distribution and the compositions of individual glucose molecules. The GNP is expected to be introduced to deliver liquid in the range of zeptoliters to attoliters, and brings a new capability for characterization of biological specimens in their near-native state.
Introduction: The Challenge of Nano-Scale Liquid Characterization
In biomedical research, observing biomolecules in their "near-native" hydrated state is crucial for understanding their function. While tools like Transmission Electron Microscopy (TEM) provide high-resolution structural data, they often struggle to deliver precise 3D chemical compositions at the atomic level. Atom Probe Tomography (APT) is the gold standard for 3D chemical mapping but requires samples to be shaped into ultra-sharp needles (radius < 75 nm) and survive high-vacuum environments. Creating a "liquid cell" that is both sharp enough for APT and robust enough to prevent evaporation has been a major technical hurdle. Furthermore, existing nanofluidic tools typically handle microliter volumes, which is far too "bulky" when dealing with rare or expensive biomolecular samples.
Methods: Rapid Fabrication of the Graphene Nanopipette
The researchers developed a fabrication method for the Graphene Nanopipette (GNP) that is both elegant and efficient, taking approximately five minutes. The process begins with a tungsten (W) tip prefabricated using a Focused Ion Beam (FIB). A small nichrome wire ring holds a liquid membrane containing the sample, with a single layer of graphene floating on top.
As the tungsten tip is pushed through the graphene-covered liquid, a portion of the graphene separates and wraps around the tip, trapping a tiny volume of liquid against the metal. The volume of the encapsulated liquid is highly controllable by tuning the encapsulating speed and the number of encapsulation rounds.
Key Insights: The Physics of Encapsulation
To understand the mechanics of this "wrapping" process, the team employed Finite Element Analysis (FEA) using the Coupled Eulerian-Lagrangian method. This modeling revealed a critical "speed limit" for successful encapsulation. If the tip moves too fast, the mechanical stress on the graphene exceeds its fracture strength (~100 GPa), leading to failure.
This maximum allowed speed increases linearly with the radius of the tungsten tip. Within these limits, the volume is remarkably predictable: dipping the tip multiple times (rounds) adds liquid linearly, while slowing the encapsulation speed increases the volume non-linearly. Furthermore, the graphene acts as an ultimate seal. Van der Waals forces cause it to adhere so tightly to the tungsten tip that it creates a vacuum-tight environment, preserving the "frozen hydrated" state of the liquid even under the extreme conditions required for APT.
Key Results and Characterization
The GNP enables reliable liquid delivery in the range of zeptoliters ($10^{-21}$ L) to attoliters ($10^{-18}$ L). Experimental measurements of liquid volume via Scanning Electron Microscopy (SEM) matched FEA simulations with a maximum deviation of only 6%.
To demonstrate the capability for single-molecule analysis, the team used laser-pulsed APT to map $^{13}$C-labeled glucose molecules. The use of isotopic labeling allowed them to definitively identify 114 individual glucose clusters amidst the background of water and metal ions. The detection of various $H_2O$ and $D_2O$ related ions confirmed that the sample remained in its native hydrated state throughout the analysis.
Limitations and Future Outlook
While the GNP excels at sealing and characterization, the primary remaining challenge is a controlled release mechanism for site-specific delivery. Current methods, such as FIB milling or ultrasonication, risk damaging the sample or the target. Future research aims to develop non-destructive release techniques and integrate GNP with cryo-TEM for a correlative microscopy workflow, providing both structural and chemical maps of the same biomolecule in its native state.
Summary updated