Geodesic density regression for correcting 4DCT pulmonary respiratory motion artifacts

Wei Shao, Wei Shao 0008, Yue Pan, Oguz C. Durumeric, Joseph M. Reinhardt, John E. Bayouth, Mirabela Rusu, Gary E. ChristensenMedical Image Analysis 2021

TL;DR

This paper introduces a novel "Geodesic Density Regression" (GDR) algorithm to correct motion artifacts in 4D CT scans of the lungs, which are crucial for radiation therapy planning. By accounting for local tissue density changes and using artifact masks, GDR significantly improves the accuracy and sharpness of reconstructed images compared to existing methods.

What Problem Does This Paper Address?

Four-dimensional computed tomography (4DCT) scans are essential for radiation therapy planning in lung cancer patients. However, these scans are prone to motion artifacts caused by irregular breathing. These artifacts manifest as duplicated, misaligned, or missing image data, which can degrade the quality of the reconstructed 4DCT images and, critically, lead to inaccurate image registration. Inaccurate registration, in turn, compromises the precision of advanced radiation therapy techniques like functional avoidance RT, which rely on precise anatomical and functional information. Existing methods often struggle with these artifacts, either by assuming constant tissue density or by being overly sensitive to data dropout.

Methods

The core of this work is the Geodesic Density Regression (GDR) algorithm. Unlike previous methods that might assume constant image intensity during deformation, GDR explicitly models and accounts for local tissue density changes that occur as lungs expand and contract. This is achieved by converting CT Hounsfield units (HU) into tissue density images.

Key methodological components include:

  • Tissue Density Deformation Action: This models how tissue density changes with deformation, using the Jacobian determinant to account for local volume changes.
  • Geodesic Image Regression Framework: GDR extends simple linear regression to a Riemannian manifold of images. It aims to find a template image ($I_T$) and a smooth 4D transformation (flow of diffeomorphisms, $\phi_t$) that best reconstructs the observed 4DCT phases.
  • Artifact Masking: Binary masks are used to identify and exclude regions with artifacts from the regression process. This makes the algorithm more robust to corrupted data.
  • Optimal Control Formulation: The problem is framed as an optimal control problem, solved using Pontryagin's Minimum Principle. This involves defining a Hamiltonian and deriving necessary conditions for optimality.
  • Flow-of-Transformations (FoT) Implementation: The authors opted for a FoT implementation of GDR, which they found to be more robust to image noise and high-frequency texture compared to a Flow-of-Images (FoI) approach.
  • U-Net for Artifact Mask Generation: A 2D U-net convolutional neural network was trained to automatically detect artifact regions and generate the necessary masks, simplifying the manual effort required for masking.

Datasets

  • Training Data: The artifact detection U-net was trained on 2084 2D coronal slices from 20 CT volumes, with manually labeled artifact locations.
  • Evaluation Data:
    • Simulated 2D CT Time-series: Synthesized artifact-free 4DCT time-series were created from 30 human subjects' 4DCT scans by registering end-expiration and end-inspiration phases and then scaling the displacement fields to generate intermediate phases. This allowed for controlled experiments with known ground truth.
  • Treatment Planning 4DCT Scans: Real 4DCT scans from 30 lung cancer patients were used to evaluate the algorithm's performance on clinically observed motion artifacts.
  • Landmarked 4DCT Scans: Seven 4DCT scans with minimal artifacts were used for evaluating image registration accuracy using mean landmark error.

Key Insights and Ideas

  • Tissue Density Matters: Explicitly modeling tissue density changes, rather than just intensity, is crucial for accurate registration of lung images, which undergo significant volume and density variations during breathing.
  • Artifact Masks Enhance Robustness: The use of artifact masks significantly improves the algorithm's resilience to missing or corrupted data, allowing it to perform well even with substantial data dropout (up to 50%).
  • Artifact Masks Don't Need to Be Perfect: The experiments showed that even imperfect artifact masks generated by a U-net provided results comparable to using perfectly labeled masks, making the process more practical.
  • GDR Produces Sharper Images: The GDR algorithm consistently produced sharper template images compared to the GIR algorithm, indicating more accurate correspondences and better reconstruction.
  • Jacobian Accuracy is Key: The primary benefit of GDR lies in its ability to produce more accurate Jacobian determinant images, which are critical for functional avoidance radiation therapy.

Key Results

  • Artifact Detection: The U-net artifact detection network achieved a True Positive Rate (TPR) of 0.846 and a True Negative Rate (TNR) of 0.999.
  • Data Dropout Robustness: GDR showed significantly less sensitivity to data dropout than the GIR algorithm. GDR performance degraded only after ~30% dropout, while GIR started declining at ~10%.
  • Duplication Artifact Correction: In simulated duplication artifact experiments, GDR produced significantly more accurate Jacobian images (p < 0.001) than GIR. The average Jacobian error in artifact regions was 0.03 for GDR vs. 0.12 for GIR.
  • Misalignment Artifact Correction: GDR successfully corrected misalignment artifacts, producing sharper images and more accurate Jacobian maps compared to GIR, which resulted in blurry images.
  • Template Image Sharpness: GDR template images were significantly sharper (p < 0.001) than GIR template images, with mean MLVs of 17.5 vs. 14.8 in lung regions for simulated duplication artifacts.
  • Mean Landmark Error: GDR reduced the mean landmark error from 7.3 mm to 1.25 mm, significantly outperforming GIR (2.4 mm) and demonstrating promising performance for aligning 4DCT scans with artifacts.

Limitations and Future Work

  • Computational Cost: The GDR algorithm is computationally intensive, requiring significant memory (up to 180GB) and time (approximately 6 hours for a single 4DCT scan on a high-performance node).
  • GPU Implementation: The authors note that implementing the algorithm on GPUs could significantly speed up computation, as current GPU memory limits are a bottleneck.
  • Sliding Motion: While GDR can accommodate sliding motion to some extent due to its composition of small transformations, it may introduce artifacts inside the lungs. Future work will investigate how well GDR can accommodate sliding motion.
  • Stationary Velocity Fields: Reducing memory requirements could be achieved by using stationary velocity fields instead of time-varying ones, though this might slightly reduce registration accuracy.
  • Further Artifact Masking Exploration: While the U-net provides good results, further exploration of automatic artifact detection and masking techniques could improve efficiency.

Summary updated