Genomic sequence characteristics and the empiric accuracy of short-read sequencing

Maximillian G. Marin, Roger Vargas, Michael A. Harris, Brendan M. Jeffrey, L. Elaine Epperson, David Durbin, Michael Strong, Max Salfinger, Zamin Iqbal, İrada Akhundova, Sergo Vashakidze, Valeriu Crudu, Alex Rosenthal, Maha FarhatbioRxiv 2021

TL;DR

This paper benchmarks short-read whole genome sequencing (WGS) for variant calling in Mycobacterium tuberculosis (Mtb), revealing that while precision is high, recall is limited in repetitive and structurally variable regions. The authors propose two strategies – tuning mapping quality thresholds and masking repetitive regions – to significantly improve variant recall, making more of the Mtb genome reliably analyzable.

What Problem Does This Paper Address?

Short-read whole genome sequencing (WGS) is a powerful tool for both clinical and research applications, but its accuracy in identifying genetic variants can be hampered by several factors. These include the inherent limitations of short reads (around 100 bp) in accurately mapping repetitive or homologous sequences, biases introduced during DNA extraction and library preparation (especially in GC-rich regions), and the reliance on a single reference genome which can lead to inaccuracies when the sequenced genome diverges. For Mycobacterium tuberculosis (Mtb), a particularly clonal pathogen, researchers often exclude a significant portion of the genome (around 10.7%) known to be repetitive and prone to erroneous variant calls. However, the precise impact of these challenges on variant calling accuracy (specifically, the loss in recall and specificity) has not been thoroughly characterized. This paper aims to systematically quantify these issues and propose improved methods for more comprehensive variant calling in Mtb.

Methods

The study employs a rigorous benchmarking approach using a combination of Illumina short-read and PacBio long-read sequencing data.

  • Hybrid Sequencing and Assembly: 36 diverse clinical Mtb isolates were dually sequenced with Illumina and PacBio. The PacBio long-reads were used to generate high-confidence, de novo genome assemblies, which then served as the "ground truth" for evaluating Illumina's performance.
  • Variant Calling: Illumina short-reads were aligned to the H37Rv reference genome, and variants (SNVs and small INDELs) were called using the Pilon software.
  • Performance Metrics: Key metrics used to assess variant calling accuracy include:
  • Empirical Base-level Recall (EBR): The proportion of isolates where Illumina confidently and correctly identified the ground truth genotype at a specific genomic position.
  • Precision: The proportion of called variants that are true positives.
  • Recall (Sensitivity): The proportion of true variants that are correctly identified.
  • F1-score: A harmonic mean of precision and recall, providing a balanced measure of performance.
  • Analysis of Error Sources: The authors systematically investigated factors influencing variant calling accuracy, including:
  • Sequence Uniqueness (Mappability): Measured using a "pileup mappability" metric to quantify how uniquely a sequence can be mapped.
  • GC Content: Assessed for its correlation with sequencing depth and coverage bias.
  • Structural Variation (SV): The impact of large genomic rearrangements on variant calling was evaluated.
  • Masking Strategies: Two primary strategies were explored to improve variant calling:
  • Tuning Mapping Quality (MQ) Threshold: Adjusting the confidence level required for a read to be considered for variant calling.
  • Masking Regions: Excluding specific genomic regions from variant calling analysis. This included:
  • Masking regions with low mappability (non-unique sequences).
  • Masking "Putative Low Confidence" (PLC) regions (genes known to be repetitive or error-prone, including PE/PPE genes and mobile genetic elements).
  • A combined approach of masking PLC regions and low mappability regions.

Datasets

The study utilized a dataset of 36 diverse clinical Mycobacterium tuberculosis (Mtb) isolates. These isolates were dually sequenced using both Illumina short-read and PacBio long-read technologies. The PacBio long-read data was crucial for generating high-confidence de novo genome assemblies, which served as the gold standard (ground truth) for evaluating the accuracy of variant calls made from the Illumina short-read data. This approach differs from in silico simulations or studies using fewer reference genomes by leveraging real-world, high-quality assemblies from a diverse set of clinical isolates.

Key Insights and Ideas

  • The "Blind Spots" of Short-Read Sequencing: The study clearly illustrates that even with high precision, short-read sequencing has inherent limitations in accurately calling variants in repetitive and structurally complex regions of the genome. This is a fundamental challenge that needs to be addressed for comprehensive genomic analysis.
  • Beyond the Excluded 10.7%: A significant finding is that a substantial portion (68%) of the typically excluded "Putative Low Confidence" (PLC) regions in Mtb can actually be accurately called using Illumina WGS. This suggests that current exclusion practices might be overly conservative and miss valuable information.
  • Mapping Quality is Key: Tuning the mapping quality (MQ) threshold emerged as a powerful and generalizable strategy to balance precision and recall. This highlights the importance of considering the confidence of read alignment when calling variants.
  • Masking as a Conservative Alternative: Masking repetitive (low mappability) regions offers a robust and generalizable approach to improve precision without requiring a ground truth dataset for threshold tuning. This is particularly valuable for applications where high precision is paramount.
  • Mtb as a Model System: The clonality and stability of the Mtb genome make it an excellent model organism for systematically dissecting the sources of variant calling error, providing insights applicable to other organisms.

Key Results

  • High Precision, Limited Recall: Illumina-based variant calling achieved high precision (≥98.5%) but recall was limited, especially in challenging genomic regions.
  • Optimal MQ Threshold: Tuning the mapping quality (MQ) threshold to ≥40 provided the best balance between precision (99.1%) and recall (85.8%) for single nucleotide variants (SNVs).
  • Masking Repetitive Regions: Masking non-unique sequences improved precision to 99.6% while maintaining a recall of 70.2% at MQ ≥ 40.
  • Accurate Calling in PLC Regions: 68% of the typically excluded PLC regions were accurately called, including 34.5% of PE/PPE genes.
  • Refined Low Confidence Regions: The authors defined a refined set of low confidence (RLC) regions, accounting for 4.0% of the H37Rv genome, which represent the largest sources of error and uncertainty. Masking these RLC regions, combined with an MQ filter of >40, yielded a mean F1-score of 0.882, with 99.9% precision and 78.9% recall.
  • Impact of Structural Variation: Regions with structural variation and low mappability showed significantly reduced variant calling performance.

Limitations and Future Work

  • Read Length Dependency: The authors note that the defined RLC regions were largely based on Illumina sequencing with 100+ bp paired-end reads. They explicitly state that these RLC regions are not recommended for shorter read lengths or single-end reads.
  • Overestimation of Performance: The reported precision and recall estimates for RLC region masking are likely overestimates because the RLC regions were defined using the same high-confidence assemblies that were evaluated.
  • Future Work:
    • The authors suggest that their findings have broad implications for Mtb biology, public health surveillance, and WGS applications in other organisms.
  • They propose that graph pan-genome approaches could further improve variant calling in divergent regions.
  • The development of a more appropriate masking scheme combining RLC regions with low pileup mappability is provided.
  • The generated dataset of high-quality genome assemblies is intended as a community resource for benchmarking future variant calling tools.

Summary updated

Abstract

Abstract Background Short-read whole genome sequencing (WGS) is a vital tool for clinical applications and basic research. Genetic divergence from the reference genome, repetitive sequences, and sequencing bias, reduce the performance of variant calling using short-read alignment, but the loss in recall and specificity has not been adequately characterized. For the clonal pathogen Mycobacterium tuberculosis (Mtb), researchers frequently exclude 10.7% of the genome believed to be repetitive and prone to erroneous variant calls. To benchmark short-read variant calling, we used 36 diverse clinical Mtb isolates dually sequenced with Illumina short-reads and PacBio long-reads. We systematically study the short-read variant calling accuracy and the influence of sequence uniqueness, reference bias, and GC content. å Results Reference based Illumina variant calling had a recall ≥89.0% and precision ≥98.5% across parameters evaluated. The best balance between precision and recall was achieved by tuning the mapping quality (MQ) threshold, i.e. confidence of the read mapping (recall 85.8%, precision 99.1% at MQ ≥ 40). Masking repetitive sequence content is an alternative conservative approach to variant calling that maintains high precision (recall 70.2%, precision 99.6% at MQ≥40). Of the genomic positions typically excluded for Mtb, 68% are accurately called using Illumina WGS including 52 of the 168 PE/PPE genes (34.5%). We present a refined list of low confidence regions and examine the largest sources of variant calling error. Conclusions Our improved approach to variant calling has broad implications for the use of WGS in the study of Mtb biology, inference of transmission in public health surveillance systems, and more generally for WGS applications in other organisms.
BibTeX
@misc{marin2021genomic,
  author = {Maximillian G. Marin and Roger Vargas and Michael A. Harris and Brendan M. Jeffrey and L. Elaine Epperson and David Durbin and Michael Strong and Max Salfinger and Zamin Iqbal and İrada Akhundova and Sergo Vashakidze and Valeriu Crudu and Alex Rosenthal and Maha Farhat},
  title = {{Genomic sequence characteristics and the empiric accuracy of short-read sequencing}},
  year = {2021},
  doi = {10.1101/2021.04.08.438862},
  howpublished = {bioRxiv},
}
Figure