Generalizable cursor click control using grasp-related neural transients

Brian M Dekleva, Jeffrey M. Weiss, Michael L. Boninger, Jennifer L. CollingermedRxiv 2020

Abstract

Intracortical brain-computer interfaces (iBCI) have the potential to restore independence for individuals with significant motor or communication impairments. One of the most realistic avenues for clinical translation of iBCI technology is to enable control of a computer cursor—i.e. movement-related neural activity is interpreted (decoded) and used to drive cursor function. Both nonhuman primate and human studies have demonstrated high-level cursor translation control using attempted upper limb reaching movements. However, cursor click control—based on identifying attempted grasp—has only been successful in providing discrete click functionality; the ability to maintain click during translation does not yet exist. Here we present a novel decoding approach for cursor click based on identifying transient neural responses that emerge at the onset and offset of intended hand grasp. We demonstrate in a human participant, who used the BCI system independently in his home, that this transient-based approach provides high-functioning, generalized click control that can be used for both point-and-click and click-and-drag applications.

Introduction

Intracortical BCIs (iBCIs) have made significant strides in translating neural activity into cursor movement. However, robust "clicking" remains a significant hurdle. Current systems typically employ a "sustained" decoding approach, attempting to detect a continuous neural signal corresponding to a held grasp. This approach often fails during complex maneuvers like "click-and-drag" because neural patterns for grasping and reaching overlap in the motor cortex. When a user moves the cursor while attempting to hold a click, the reaching signals can interfere with or attenuate the grasp signals, leading to unreliable performance.

Methods and Experimental Design

This study involved a single participant (P2), a man with tetraplegia, utilizing an at-home portable iBCI system. Researchers compared two primary decoding architectures:

  1. Sustained Decoder (Baseline): A standard Linear Discriminant Analysis (LDA) classifier trained to distinguish between "clicked" and "unclicked" states continuously.
  2. Transient-Based Decoder (Innovation): This approach utilizes two independent LDA classifiers to detect the onset (initiation of squeeze) and offset (initiation of release) of a grasp.

Neural firing rates were processed using Factor Analysis for dimensionality reduction (20-dimensional state space) to prevent overfitting. A temporal grid search identified optimal 500ms windows where neural transients were most discriminable.

Figure 1: Experimental tasks for discrete and sustained click calibration and evaluation. (a-b) Calibration sequences with corresponding x and y velocity profiles. (c-d) Evaluation tasks involving point-and-click and click-and-drag maneuvers.

Datasets and Evaluation

Data were recorded from two 88-channel microelectrode arrays in the participant's motor cortex over multiple sessions (1795–1909 days post-implant).

  • Calibration: Tasks included discrete click center-out and sustained click center-out protocols.
  • Evaluation: Performance was assessed using helicopter-themed games requiring both "point-and-click" (discrete) and "click-and-drag" (sustained) functionality.

Key Insights: The Power of Transients

The core finding is that neural responses at the beginning and end of a grasp (transients) are consistently more salient than activity during a sustained hold. By focusing on these transitions, the system effectively decouples click control from cursor translation. Because the cursor is typically stationary when a click is initiated or terminated, these signals are less likely to be obscured by movement-related neural activity. The system functions as a state-machine toggle: once an onset is detected, the "clicked" state is maintained until an offset signal is identified, regardless of intervening reaching activity.

Results

The transient-based decoder demonstrated superior performance and generalizability:

  • Click-and-Drag Performance: While the sustained decoder failed almost entirely at click-and-drag tasks involving movement, the transient-based decoder achieved success rates up to 82%.
  • Robustness: The transient decoder performed well regardless of the calibration task (discrete vs. sustained), whereas the sustained decoder was highly sensitive to calibration conditions.
  • Latency and Stability: Both decoders showed similar click latencies (~0.56s). However, the sustained decoder suffered from premature releases (0.12s latency) due to signal interference during movement, a problem the transient approach avoided.
  • Functional Utility: The participant successfully performed real-world tasks like digital painting and card games, which require frequent, reliable clicking and dragging.

Discussion and Future Directions

While this N=1 study demonstrates a significant breakthrough, broader validation is required. The current binary control (single click type) could be expanded to include multiple click types (e.g., right-click) by identifying different neural transients. Furthermore, this transient-based approach holds promise for improving the reliability of robotic limb control in physical grasping and manipulation tasks.

Summary updated

Abstract

Abstract Intracortical brain-computer interfaces (iBCI) have the potential to restore independence for individuals with significant motor or communication impairments. One of the most realistic avenues for clinical translation of iBCI technology is to enable control of a computer cursor—i.e. movement-related neural activity is interpreted (decoded) and used to drive cursor function. Both nonhuman primate and human studies have demonstrated high-level cursor translation control using attempted upper limb reaching movements. However, cursor click control—based on identifying attempted grasp—has only been successful in providing discrete click functionality; the ability to maintain click during translation does not yet exist. Here we present a novel decoding approach for cursor click based on identifying transient neural responses that emerge at the onset and offset of intended hand grasp. We demonstrate in a human participant, who used the BCI system independently in his home, that this transient-based approach provides high-functioning, generalized click control that can be used for both point-and-click and click-and-drag applications.
BibTeX
@misc{dekleva2020generalizable,
  author = {Brian M Dekleva and Jeffrey M. Weiss and Michael L. Boninger and Jennifer L. Collinger},
  title = {{Generalizable cursor click control using grasp-related neural transients}},
  year = {2020},
  doi = {10.1101/2020.09.03.20186973},
  howpublished = {medRxiv},
}
Figure