Gas chromatographic method for the quantification of the new calcium antagonist benidipine hydrochloride in plasma using electron capture detection.
Lists
Only you see this
Abstract
A gas chromatographic assay procedure was developed for measuring subnanogram order concentrations of (+/-)-(R*)-2,6-dimethyl-4-(m-nitrophenyl)-1,4-dihydropyridine-3,5- dicarboxylic acid (R*)-1-benzyl-3-piperidinyl ester, methyl ester hydrochloride (benidipine hydrochloride, KW-3049) in plasma. KW-3049 yielded the oxidation product partially during gas chromatography. To avoid decomposition, KW-3049 was oxidized in advance by nitrogen dioxide, extracted by diethylether under alkaline condition, chromatographed on the OV-1 column and measured using electron capture detector.
BibTeX
@inproceedings{kobayashi1988gas,
author = {Hiroyuki Kobayashi and Satoshi Kobayashi and A Inoue and Tatsushi Oka and N Nakamizo},
title = {{Gas chromatographic method for the quantification of the new calcium antagonist benidipine hydrochloride in plasma using electron capture detection.}},
booktitle = {PubMed},
year = {1988},
}Loading related content...