Fusing Diverse Decision Rules in 3D-Radiomics for Assisting Diagnosis of Lung Adenocarcinoma

He Ren, Qiubo Wang, Zhengguang Xiao, Runwei Mo, Jiachen Guo, Gareth Richard Hide, Mengting Tu, Yanan Zeng, Ling Chen, Ping LiJournal of Imaging Informatics in Medicine 2024

Abstract

This study aimed to develop an interpretable diagnostic model for subtyping of pulmonary adenocarcinoma, including minimally invasive adenocarcinoma (MIA), adenocarcinoma in situ (AIS), and invasive adenocarcinoma (IAC), by integrating 3D-radiomic features and clinical data. Data from multiple hospitals were collected, and 10 key features were selected from 1600 3D radiomic signatures and 11 radiological features. Diverse decision rules were extracted using ensemble learning methods (gradient boosting, random forest, and AdaBoost), fused, ranked, and selected via RuleFit and SHAP to construct a rule-based diagnostic model. The model's performance was evaluated using AUC, precision, accuracy, recall, and F1-score and compared with other models. The rule-based diagnostic model exhibited excellent performance in the training, testing, and validation cohorts, with AUC values of 0.9621, 0.9529, and 0.8953, respectively. This model outperformed counterparts relying solely on selected features and previous research models. Integrating diverse decision rules enhanced the accuracy and interpretability of the diagnostic model for lung adenocarcinoma subtypes, bridging the gap between complex predictive models and clinical utility.

Introduction

Lung adenocarcinoma is the most prevalent form of lung cancer, characterized by a spectrum of subtypes that dictate clinical management. These range from pre-invasive lesions like Adenocarcinoma in situ (AIS) and Minimally Invasive Adenocarcinoma (MIA) to aggressive Invasive Adenocarcinoma (IAC). While AIS and MIA often require limited surgical intervention and carry excellent prognoses, IAC necessitates more intensive treatments such as chemotherapy or radiotherapy.

Accurate preoperative subtyping is critical but challenging. While artificial intelligence (AI) and deep learning have shown promise in medical imaging, their "black box" nature often hinders clinical adoption. Physicians require transparent, interpretable logic to trust algorithmic diagnoses. This research addresses the "interpretability gap" by developing a diagnostic model that fuses decision rules from multiple machine learning ensembles into a human-readable format.

Methodology

The study utilized a multi-center dataset comprising 506 pulmonary nodules from three institutions: Shanghai Public Health Clinical Center, Shanghai Ruijin Hospital, and Ningbo Beilun NO.2 Hospital. The data was partitioned into training (282), testing (139), and external validation (85) cohorts.

Feature Engineering and Selection

The diagnostic pipeline began with the extraction of 1,611 features: 1,600 3D radiomic signatures derived from CT scans and 11 clinical/radiological features. To manage this high-dimensional space, the researchers employed a two-stage selection process. First, mRMR (minimum redundancy maximum relevance) identified the most relevant radiomic features. Subsequently, LASSO (least absolute shrinkage and selection operator) was applied to both radiomic and clinical features to distill the set down to the 10 most impactful predictors.

The multi-stage diagnostic pipeline illustrating feature extraction, selection, and rule fusion.

Rule Fusion and Model Construction

Rather than relying on a single classifier, the authors leveraged the strengths of three diverse ensemble methods: Gradient Boosting Decision Trees (GBDT), Random Forest, and AdaBoost. These models generated a vast pool of decision rules. Using the RuleFit algorithm and SHAP (Shapley Additive Explanations), the 15 most robust and interpretable rules were selected. These rules take the form of logical "if-then" statements, mimicking the heuristic decision-making process of experienced radiologists. Finally, these rules were integrated into a multivariate logistic regression model to provide a definitive risk assessment.

Results and Discussion

The rule-based model demonstrated superior performance across all metrics. In the training cohort, it achieved an AUC of 0.9621. This performance remained robust in the testing (AUC 0.9529) and external validation (AUC 0.8953) cohorts. Notably, the fused model outperformed individual ensemble models (GBDT, Random Forest, and AdaBoost) and previous state-of-the-art research models, which typically achieved AUCs between 0.83 and 0.89.

Feature Importance and Clinical Correlation

The 10 selected features included morphological indicators like "spiculated margin" and "pleural indentation," alongside complex radiomic textures. Analysis revealed that "Original_shape_MajorAxisLength" was the most pivotal discriminant, with specific thresholds (12.46mm and 9.93mm) acting as critical tipping points between invasive and non-invasive subtypes.

Heatmap showing the correlation between the 10 key features selected for the diagnostic model.

The model's logic aligns with clinical intuition, progressing from morphology (size/shape) to intensity (CT values) and finally to texture (heterogeneity). This alignment enhances clinician confidence, as the model's "reasoning" is verifiable against radiological observations.

Conclusion

By fusing diverse decision rules, this study successfully bridged the gap between complex predictive modeling and clinical utility. The resulting "glass box" model offers high diagnostic accuracy for lung adenocarcinoma subtyping while providing the transparency necessary for real-world medical application. Future work will focus on prospective clinical trials and expanding the dataset to further validate these findings across diverse populations and imaging protocols.

Summary updated

Abstract

This study aimed to develop an interpretable diagnostic model for subtyping of pulmonary adenocarcinoma, including minimally invasive adenocarcinoma (MIA), adenocarcinoma in situ (AIS), and invasive adenocarcinoma (IAC), by integrating 3D-radiomic features and clinical data. Data from multiple hospitals were collected, and 10 key features were selected from 1600 3D radiomic signatures and 11 radiological features. Diverse decision rules were extracted using ensemble learning methods (gradient boosting, random forest, and AdaBoost), fused, ranked, and selected via RuleFit and SHAP to construct a rule-based diagnostic model. The model's performance was evaluated using AUC, precision, accuracy, recall, and F1-score and compared with other models. The rule-based diagnostic model exhibited excellent performance in the training, testing, and validation cohorts, with AUC values of 0.9621, 0.9529, and 0.8953, respectively. This model outperformed counterparts relying solely on selected features and previous research models. Specifically, the AUC values for the previous research models in the three cohorts were 0.851, 0.893, and 0.836. It is noteworthy that individual models employing GBDT, random forest, and AdaBoost demonstrated AUC values of 0.9391, 0.8681, and 0.9449 in the training cohort, 0.9093, 0.8722, and 0.9363 in the testing cohort, and 0.8440, 0.8640, and 0.8750 in the validation cohort, respectively. These results highlight the superiority of the rule-based diagnostic model in the assessment of lung adenocarcinoma subtypes, while also providing insights into the performance of individual models. Integrating diverse decision rules enhanced the accuracy and interpretability of the diagnostic model for lung adenocarcinoma subtypes. This approach bridges the gap between complex predictive models and clinical utility, offering valuable support to healthcare professionals and patients.
BibTeX
@article{ren2024fusing,
  author = {He Ren and Qiubo Wang and Zhengguang Xiao and Runwei Mo and Jiachen Guo and Gareth Richard Hide and Mengting Tu and Yanan Zeng and Ling Chen and Ping Li},
  title = {{Fusing Diverse Decision Rules in 3D-Radiomics for Assisting Diagnosis of Lung Adenocarcinoma}},
  journal = {Journal of Imaging Informatics in Medicine},
  year = {2024},
  doi = {10.1007/s10278-024-00967-5},
}
Figure