Functionalized graphene-based biomimetic microsensor interfacing with living cells to sensitively monitor nitric oxide release

Yan‐Ling Liu, Xueying Wang, Jiaquan Xu, Chong Xiao, Yanhong Liu, Xinwei Zhang, Wenyu Liu, Wei‐Hua HuangChemical 2015 · DOI

TL;DR

Researchers have developed a novel, reusable biomimetic microsensor using functionalized graphene that can sensitively detect nitric oxide (NO) release from living cells at the single-cell level. This breakthrough offers a powerful tool for understanding NO's physiological roles and for medical diagnostics.

What Problem Does This Paper Address?

Nitric oxide (NO) is a crucial signaling molecule involved in numerous physiological processes, but its extremely short half-life and low physiological concentrations (down to picomolar levels) make it incredibly difficult to measure accurately in real-time within living systems. Existing methods often lack the required sensitivity, selectivity, or biocompatibility for single-cell monitoring. Specifically, developing electrochemical sensors that are both highly sensitive and biocompatible, allowing for direct interface with living cells without harming them, remains a significant challenge. Furthermore, achieving this at the single-cell level, where NO concentrations are even lower and more localized, adds another layer of complexity.

Methods

The core innovation lies in the development of a multi-component sensing material and its integration onto a microelectrode array.

  • Graphene Oxide (GO) Functionalization: Reduced graphene oxide (rGO) was chosen for its excellent electrical conductivity. This rGO was then functionalized with metalloporphyrin (specifically, Fe(III) meso-tetra(4-carboxyphenyl) porphyrin, FeTCP) through π-π interactions. This hybrid material, termed FGHNs, combines the catalytic properties of FeTCP for NO sensing with the conductivity of rGO.
  • Biomimetic Interface: To enhance biocompatibility and enable cell adhesion, the FGHNs were further modified with 3-aminophenylboronic acid (APBA). APBA acts as a biomimetic interface by reversibly binding to the carbohydrate moieties present on cell membranes. This allows cells to adhere and proliferate on the sensor surface without compromising NO detection sensitivity.
  • Microsensor Fabrication: The APBA-functionalized FGHNs were deposited onto patterned indium tin oxide (ITO) microelectrode arrays using electrophoretic deposition. This creates an array of individual sensing sites capable of monitoring multiple cells or a small cluster of cells.
  • Electrochemical Detection: The sensor utilizes electrochemical techniques, specifically differential pulse voltammetry and amperometry, to detect NO. NO is electrochemically oxidized at the sensor surface, generating a measurable current proportional to its concentration.

Datasets

Not discussed in the paper. The study focuses on in vitro experiments using cell culture media and controlled NO solutions, rather than large-scale datasets for training or evaluation.

Key Insights and Ideas

  • Synergistic Material Design: The combination of a catalytic metalloporphyrin with conductive rGO is key to achieving high sensitivity for NO detection. The rGO acts as an efficient electron highway, overcoming the poor conductivity of the porphyrin alone.
  • Biomimetic Reusability: The use of APBA not only promotes cell adhesion but also enables sensor reusability. The reversible binding of APBA to cell carbohydrates allows for easy detachment of cells and subsequent sensor renewal, a significant advantage for long-term studies.
  • Single-Cell Sensitivity: The sensor achieves sub-nanomolar sensitivity, with detection limits as low as 55 PM in PBS and 90 PM in cell medium. This level of sensitivity is crucial for detecting the low concentrations of NO released by individual cells.
  • Enhanced Selectivity: The functionalized sensor demonstrates good selectivity against common interfering species found in biological samples, such as ascorbic acid, dopamine, and nitrite, further validating its utility in complex environments.

Key Results

  • Sub-nanomolar Sensitivity: The APBA/FGHNs/ITO microsensor achieved a detection limit of 55 PM in PBS and 90 PM in cell medium, which are among the lowest reported for NO electrochemical sensors.
  • High Sensitivity: The sensitivity of the FGHNs/ITO sensor was significantly higher (37.6 μA μM⁻¹ cm⁻²) compared to rGO/ITO (7.2 μA μM⁻¹ cm⁻²) and FeTCP/ITO (2.1 μA μM⁻¹ cm⁻²).
  • Excellent Biocompatibility: Human umbilical vein endothelial cells (HUVECs) adhered, proliferated, and maintained high viability on the APBA/FGHNs/ITO surface, demonstrating excellent cytocompatibility.
  • Real-time NO Monitoring: The sensor successfully monitored NO release from HUVECs in real-time upon stimulation with L-arginine, showing a clear correlation between cell number and NO signal.
  • Sensor Reusability: The microsensor maintained over 80% of its initial response after five cycles of cell detection and sensor renewal, highlighting its practical reusability.

Limitations and Future Work

  • In Vivo Limitations: While the sensor demonstrates excellent performance in cell culture media, direct in vivo monitoring of NO at extremely low bioactive concentrations has not yet been demonstrated. This is a crucial next step for fully realizing its potential in physiological and pathological conditions.
  • Interferent Specificity: Although good selectivity was shown, the paper notes that positively charged interferents like dopamine and 5-HT still showed small detectable signals. Further refinement might be needed for absolute specificity in highly complex biological matrices.
  • Integration with Other Techniques: The authors mention the sensor is transparent and could be coupled with optical imaging techniques. Future work could explore this integration for correlative microscopy and electrochemical studies.
  • Microfabrication Complexity: While the paper mentions photolithography for microelectrode array fabrication, the complexity of this process might be a consideration for large-scale manufacturing.

The authors suggest that this sensor's exceptional sensitivity, biocompatibility, and reusability make it a promising candidate for integration into microfluidic or implantable devices for advanced real-time NO monitoring.

Summary updated

Abstract

It is a great challenge to develop electrochemical sensors with superior sensitivity that concurrently possess high biocompatibility for monitoring at the single cell level. Herein we report a novel and reusable biomimetic micro-electrochemical sensor array with nitric oxide (NO) sensing-interface based on metalloporphyrin and 3-aminophenylboronic acid (APBA) co-functionalized reduced graphene oxide (rGO). The assembling of high specificity catalytic but semi-conductive metalloporphyrin with high electric conductive rGO confers the sensor with sub-nanomolar sensitivity. Further coupling with the small cell-adhesive molecule APBA obviously enhances the cytocompatibility of the microsensor without diminishing the sensitivity, while the reversible reactivity between APBA and cell membrane carbohydrates allows practical reusability. The microsensor was successfully used to sensitively monitor, in real-time, the release of NO molecules from human endothelial cells being cultured directly on the sensor. This demonstrates its potential application in the detection of NO with very low bioactive concentrations for the better understanding of its physiological function and for medical tracking of patient states.
BibTeX
@inproceedings{liu2015functionalized,
  author = {Yan‐Ling Liu and Xueying Wang and Jiaquan Xu and Chong Xiao and Yanhong Liu and Xinwei Zhang and Wenyu Liu and Wei‐Hua Huang},
  title = {{Functionalized graphene-based biomimetic microsensor interfacing with living cells to sensitively monitor nitric oxide release}},
  booktitle = {Chemical},
  year = {2015},
  doi = {10.1039/c4sc03123g},
}
Figure