From Maxwell's equations to the theory of current‐source density analysis

Sergey L. Gratiy, Geir Halnes, Daniel J. Denman, Michael Hawrylycz, Christof Koch, Gaute T. Einevoll, Costas A. AnastassiouEuropean 2017 · DOI

TL;DR

This paper revisits the foundational theory of Current-Source Density (CSD) analysis, showing how it can be rigorously derived from Maxwell's equations. The authors demonstrate that while transmembrane currents are the primary drivers, extracellular diffusion currents can significantly influence low-frequency extracellular potentials, necessitating their consideration for accurate CSD estimates.

What Problem Does This Paper Address?

Current-Source Density (CSD) analysis is a powerful technique for inferring the spatial and temporal distribution of transmembrane currents in neural tissue from extracellular recordings, like the Local Field Potential (LFP). However, the underlying assumptions of the original CSD theory have been questioned. Specifically, some recent studies suggest that other electrical currents in the extracellular space – such as diffusion, advection, and displacement currents – might contribute significantly to the recorded potentials, potentially confounding CSD estimates. This paper aims to reconcile these differing views by providing a more comprehensive theoretical framework for CSD analysis, starting from fundamental electromagnetic principles.

Methods

The authors begin by grounding their analysis in Maxwell's equations, which describe the behavior of electric and magnetic fields. They then apply two key approximations relevant to physiological signals:

  1. Electro-quasistatic approximation: This simplifies Maxwell's equations by neglecting magnetic induction, which is valid for the low frequencies typically encountered in neural activity. This allows them to express the electric field as the gradient of a scalar potential.
  2. Coarse-graining: To bridge the gap between the microscopic world of individual neurons and the macroscopic scale of extracellular recordings, they introduce a spatial averaging procedure. This averaging is performed separately over cellular and extracellular spaces, leading to a "bi-domain" representation of brain tissue.

Using this framework, they derive a generalized Poisson equation for the extracellular potential. This equation explicitly includes the CSD of transmembrane currents and the divergence of extracellular diffusion currents as sources. They also analyze the contributions of advective and displacement currents, finding them to be negligible in the extracellular space at physiological frequencies.

Datasets

The paper utilizes experimental data for validation:

  • Electrophysiological recordings: High-density extracellular recordings (LFP) from the mouse primary visual cortex were obtained in response to visual stimuli (ON/OFF flashes).
  • Extracellular ion concentration data: Previously published data on extracellular [K+] transients in cat visual cortex following electrical thalamic stimulation were used.

These datasets were used to compare the CSD estimated under standard assumptions with the potential influence of extracellular diffusion currents.

Key Insights and Ideas

  • Reconciling CSD theory with diffusion: The paper provides a rigorous derivation that shows how extracellular diffusion currents can contribute to the extracellular potential, particularly at frequencies below a few Hertz. This offers a theoretical basis for understanding why some studies have observed discrepancies with traditional CSD assumptions.
  • Generalized Poisson equation: The authors derive a more general form of the Poisson equation for extracellular potentials that explicitly accounts for both transmembrane currents (via CSD) and extracellular diffusion currents. This is a significant theoretical advancement.
  • Frequency-dependent influence of diffusion: The analysis highlights that diffusion currents are primarily a low-frequency phenomenon. This means that for typical LFP analysis (which often focuses on frequencies above a few Hz), their impact might be minimal, but for slower oscillations or pathological states with significant ion concentration changes, they become crucial.
  • Displacement current's role: While advective and displacement currents are deemed negligible in the extracellular space, the displacement current within cellular membranes is shown to contribute to the CSD as a capacitive current.

Key Results

  • The study demonstrates that the generalized Poisson equation for extracellular potential, derived from Maxwell's equations, includes both the CSD of transmembrane currents and the divergence of extracellular diffusion currents.
  • Analysis of experimental data (Fig. 2C) shows that the estimated contribution of extracellular diffusion to the apparent CSD has significant power at frequencies ≤1 Hz, rapidly attenuating at higher frequencies. This supports the idea that diffusion primarily affects low-frequency LFP components.
  • The paper provides a theoretical framework that clarifies the relationship between electric currents and extracellular potentials, forming a foundation for more accurate CSD analysis.

Limitations and Future Work

  • Experimental limitations: The authors acknowledge that obtaining simultaneous, high-resolution measurements of extracellular potentials and ion concentrations across all three spatial dimensions is challenging, necessitating approximations in their analysis.
  • Noise amplification: Spatial differentiation in CSD estimation inherently amplifies noise, requiring sophisticated regularization techniques, which are a known challenge in the practical application of CSD analysis.
  • Future directions: The paper suggests that their generalized framework can be used to develop more accurate CSD estimation methods that account for diffusion. Future work could focus on developing practical algorithms that can effectively subtract or incorporate the diffusion component for a more precise understanding of neural activity. The authors also point out that their theory provides a more general basis for understanding extracellular potentials, which could be extended to other phenomena like evoked potentials.

Summary updated

Abstract

Despite the widespread use of current-source density (CSD) analysis of extracellular potential recordings in the brain, the physical mechanisms responsible for the generation of the signal are still debated. While the extracellular potential is thought to be exclusively generated by the transmembrane currents, recent studies suggest that extracellular diffusive, advective and displacement currents-traditionally neglected-may also contribute considerably toward extracellular potential recordings. Here, we first justify the application of the electro-quasistatic approximation of Maxwell's equations to describe the electromagnetic field of physiological origin. Subsequently, we perform spatial averaging of currents in neural tissue to arrive at the notion of the CSD and derive an equation relating it to the extracellular potential. We show that, in general, the extracellular potential is determined by the CSD of membrane currents as well as the gradients of the putative extracellular diffusion current. The diffusion current can contribute significantly to the extracellular potential at frequencies less than a few Hertz; in which case it must be subtracted to obtain correct CSD estimates. We also show that the advective and displacement currents in the extracellular space are negligible for physiological frequencies while, within cellular membrane, displacement current contributes toward the CSD as a capacitive current. Taken together, these findings elucidate the relationship between electric currents and the extracellular potential in brain tissue and form the necessary foundation for the analysis of extracellular recordings.
BibTeX
@inproceedings{gratiy2017from,
  author = {Sergey L. Gratiy and Geir Halnes and Daniel J. Denman and Michael Hawrylycz and Christof Koch and Gaute T. Einevoll and Costas A. Anastassiou},
  title = {{From Maxwell's equations to the theory of current‐source density analysis}},
  booktitle = {European},
  year = {2017},
  doi = {10.1111/ejn.13534},
}

Loading related content...

Figure