Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study

Xinyue Liang, Zhenghong Bi, Chun Yang, Ruofan Sheng, Xinyuan Xia, Zheng Zhang, Yongming Dai, Mengsu ZengFrontiers in Oncology 2022 · DOI

Abstract

For volunteers, the performance of T2WI as well as DWI with three respiratory-trigger techniques was similarly good. As for patients, FT-DWI is superior to BT and NT techniques in terms of higher lesion SNR and CNR at b50.

Introduction

Abdominal MRI is inherently challenging due to respiratory motion, which often leads to image artifacts like ghosting and blurring. These artifacts can obscure small lesions, complicating diagnosis. Current clinical practice relies on three primary strategies: breath-holding, which is difficult for compromised patients; respiratory belts (BT), which require physical contact and setup time; and navigator-triggers (NT), which track the diaphragm but can be inefficient. This study evaluates a novel, contactless frequency-modulated continuous-wave (FMCW) radar-trigger (FT) technique designed to improve both workflow efficiency and patient comfort without compromising diagnostic quality.

Methods

This prospective, single-center trial involved 40 subjects, including 17 healthy volunteers and 23 patients with liver diseases (primarily liver cancer and hemangiomas). Imaging was performed on a 1.5T MRI scanner integrated with a 4 GHz FMCW radar system. The radar system automatically reconstructs respiratory curves from body movement without requiring physical contact. The study compared the FT technique against the industry-standard BT and NT methods. Evaluation included qualitative assessments by radiologists using Likert scales and quantitative measurements of Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR), and Apparent Diffusion Coefficient (ADC) values.

Results and Discussion

Workflow Efficiency and Scan Time

The FT technique significantly streamlines the MRI workflow. Unlike BT, which requires physical positioning of a belt, or NT, which requires calibration of a navigator beam, the radar system is integrated and automated, allowing for a "set it and forget it" approach.

Schematic illustration of the MRI workflow comparing BT, NT, and FT techniques.

Quantitative analysis showed that for T2-weighted imaging (T2WI), the FT technique was significantly faster than the NT method, with average scan times of approximately 143 seconds versus 179 seconds ($p < 0.01$).

Image Quality and Lesion Conspicuity

While NT remains a strong performer for T2WI sharpness due to direct diaphragm tracking, the FT technique demonstrated superior performance in Diffusion-Weighted Imaging (DWI), particularly at low b-values ($b=50$). In patients, FT-DWI achieved a significantly higher SNR ($705.13 \pm 434.80$) and CNR ($504.41 \pm 400.69$) compared to both BT and NT.

Example abdominal T2WI and DWI images showing better vessel visualization with the FT technique.

Importantly, ADC values remained consistent across all three techniques, ensuring that the radar method does not interfere with quantitative tissue characterization used to distinguish benign from malignant lesions.

Conclusion

The preliminary results suggest that the contactless radar-trigger technique is a viable and efficient alternative for liver MRI. It offers comparable image quality to traditional methods while improving patient comfort and reducing scan times. Future research with larger cohorts and higher-field (3.0T) systems is needed to further validate these findings across a broader range of pathologies and patient populations.

Summary updated

Abstract

For volunteers, the performance of T2WI as well as DWI with three respiratory-trigger techniques was similarly good. As for patients, FT-DWI is superior to BT and NT techniques in terms of higher lesion SNR and CNR at b50.
BibTeX
@inproceedings{liang2022free,
  author = {Xinyue Liang and Zhenghong Bi and Chun Yang and Ruofan Sheng and Xinyuan Xia and Zheng Zhang and Yongming Dai and Mengsu Zeng},
  title = {{Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study}},
  booktitle = {Frontiers in Oncology},
  year = {2022},
  doi = {10.3389/fonc.2022.918173},
}
Figure