Framework for lumen-based nonrigid tomographic coregistration of intravascular images
Lists
Only you see this
Abstract
<b>Purpose:</b> Modern medical imaging enables clinicians to effectively diagnose, monitor, and treat diseases. However, clinical decision-making often relies on combined evaluation of either longitudinal or disparate image sets, necessitating coregistration of multiple acquisitions. Promising coregistration techniques have been proposed; however, available methods predominantly rely on time-consuming manual alignments or nontrivial feature extraction with limited clinical applicability. Addressing these issues, we present a fully automated, robust, nonrigid registration method, allowing for coregistering of multimodal tomographic vascular image datasets using luminal annotation as the sole alignment feature. <b>Approach:</b> Registration is carried out by the use of the registration metrics defined exclusively for lumens shapes. The framework is primarily broken down into two sequential parts: longitudinal and rotational registration. Both techniques are inherently nonrigid in nature to compensate for motion and acquisition artifacts in tomographic images. <b>Results:</b> Performance was evaluated across multimodal intravascular datasets, as well as in longitudinal cases assessing pre-/postinterventional coronary images. Low registration error in both datasets highlights method utility, with longitudinal registration errors-evaluated throughout the paired tomographic sequences-of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.29</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.14</mml:mn> <mml:mtext> </mml:mtext> <mml:mi>mm</mml:mi></mml:mrow> </mml:math> ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mo><</mml:mo> <mml:mn>2</mml:mn></mml:mrow> </mml:math> longitudinal image frames) and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>0.18</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.16</mml:mn> <mml:mtext> </mml:mtext> <mml:mi>mm</mml:mi></mml:mrow> </mml:math> ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mo><</mml:mo> <mml:mn>1</mml:mn></mml:mrow> </mml:math> frame) for multimodal and interventional datasets, respectively. Angular registration for the interventional dataset rendered errors of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>7.7</mml:mn> <mml:mo>°</mml:mo> <mml:mo>±</mml:mo> <mml:mn>6.7</mml:mn> <mml:mo>°</mml:mo></mml:mrow> </mml:math> , and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>29.1</mml:mn> <mml:mo>°</mml:mo> <mml:mo>±</mml:mo> <mml:mn>23.2</mml:mn> <mml:mo>°</mml:mo></mml:mrow> </mml:math> for the multimodal set. <b>Conclusions:</b> Satisfactory results across datasets, along with additional attributes such as the ability to avoid longitudinal over-fitting and correct nonlinear catheter rotation during nonrigid rotational registration, highlight the potential wide-ranging applicability of our presented coregistration method.
BibTeX
@article{karmakar2022framework,
author = {A. Karmakar and Max L. Olender and David Marlevi and Evan Shlofmitz and Richard Shlofmitz and Elazer R. Edelman and Farhad R. Nezami},
title = {{Framework for lumen-based nonrigid tomographic coregistration of intravascular images}},
journal = {Journal of Medical Imaging},
year = {2022},
doi = {10.1117/1.jmi.9.4.044006},
}Loading related content...