NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Fourier Series Analysis for Novel Spatiotemporal Pulse Waves: Normal, Taut, and Slippery Pulse Images

Bo Peng, Ching‐Hsing Luo, Nilotpal Sinha, Cheng‐Chi Tai, Xiaohua Xie, Haiqing XieEvidence-based 2019

TL;DR

This paper introduces a novel method using Fourier series analysis to characterize spatiotemporal pulse waves captured as 3D images. By analyzing the harmonic ratios of spatial pulse wave components, the researchers can effectively differentiate between "normal," "taut," and "slippery" pulse types, offering a quantitative approach to traditional Chinese medicine pulse diagnosis.

What Problem Does This Paper Address?

Traditional Chinese Medicine (TCM) has long relied on pulse diagnosis, a non-invasive method that assesses a patient's health by palpating the radial pulse. This diagnosis considers both the temporal (how the pulse changes over time) and spatial (the shape and distribution of the pulse wave) characteristics. While various instruments have been developed to measure these pulses, translating the nuanced "feeling" of a pulse into objective, quantifiable metrics remains a challenge. Previous work has visualized pulse waves as 3D images (3DPIs), but a robust method to analyze their complex spatiotemporal features, particularly for differentiating subtle pulse qualities like "taut" and "slippery," was needed.

Methods

The core of this research lies in applying Fourier series analysis to the 3D pulse images (3DPIs) generated by a specialized pulse diagnostic instrument. Instead of just analyzing the temporal aspect of the pulse, the authors focus on the spatial characteristics captured within the 3DPI.

Here's a breakdown of their approach:

  • 3D Pulse Image (3DPI) Generation: Pulse data from tactile array sensors is processed to create a 3D representation of the pulse wave. A 2D pulse image (2DPI) is then derived by taking the central slice of the 3DPI.
  • Fourier Series Analysis:
    • Temporal: Fourier series are applied to the temporal pulse wave to analyze its harmonic components.
  • Spatial: Crucially, Fourier series are also applied to the spatial wave shape of the pulse. The authors found that for spatial analysis, the first three harmonics (base, C₁, and C₂) were sufficient to capture the essential information.
  • Harmonic Ratio Calculation: To quantify the spatial pulse characteristics, they define harmonic ratios:
  • r₀ = C₀ / (C₀ + C₁ + C₂) (base harmonic ratio)

    • r₁ = C₁ / (C₀ + C₁ + C₂) (first harmonic ratio)
    • r₂ = C₂ / (C₀ + C₁ + C₂) (second harmonic ratio) These ratios represent the relative contribution of each harmonic to the overall spatial pulse wave.
  • Ratio Sequence and Statistics: For each heartbeat, a sequence of these harmonic ratios is generated. The average of the first harmonic ratio (r̄₁) and the difference between the peak r₁ and the average r₁ (Δr₁) are then calculated. These statistical measures are used to differentiate between pulse types.

Datasets

The study utilized pulse data collected from 24 healthy subjects (14 males, 10 females) with an average age of 22.2 ± 3.7 years, BMI of 20.4 ± 1.4, and systolic blood pressure of 112.1 ± 4.7 mmHg.

  • Normal Pulse: Obtained from subjects in their normal state.
  • Taut Pulse: Induced by a cold pressor test (CPT), a method known to affect arterial stiffness.
  • Slippery Pulse: Measured from female subjects during their menstrual cycle, a condition that can influence pulse characteristics.

The paper does not introduce a new benchmark dataset but rather uses data collected from human subjects under controlled conditions to simulate specific pulse types.

Key Insights and Ideas

  • Spatial Analysis is Key: The temporal Fourier series showed minimal differences between pulse types, highlighting that the critical information for differentiating "normal," "taut," and "slippery" pulses lies in their spatial characteristics.
  • Harmonic Ratios as Discriminators: The defined harmonic ratios (r₀, r₁, r₂) provide a powerful quantitative tool. The distinct patterns of these ratio sequences for each pulse type (e.g., well-distributed for normal, merged for taut, intersecting for slippery) are a significant finding.
  • r̄₁ and Δr₁ as Effective Metrics: The average first harmonic ratio (r̄₁) and its difference (Δr₁) emerged as statistically significant indicators for distinguishing between the pulse types, offering a novel way to quantify TCM pulse feelings.
  • Slippery Pulse Complexity: The observation of two distinct spatial peaks in the slippery pulse (as seen in Figure 3) and the resulting intersection of harmonic ratio sequences is a key insight into its unique spatiotemporal behavior.

Key Results

  • Statistical Significance: The study found significant statistical differences in r̄₁ and Δr₁ between the normal, taut, and slippery pulse groups.
  • Differentiation Capability: The proposed harmonic ratio sequence method effectively differentiates among the three pulse images, as summarized in Table 2.
  • Normal Pulse: Ratio sequences are well-distributed.
  • Taut Pulse: The base ratio (r₀) is dominant, with r₁ and r₂ merged.
  • Slippery Pulse: The r₁ and r₂ sequences intersect, reflecting its complex spatial wave.
  • Comparison with Existing Methods: The paper's proposed method ([r₁, Δr₁]) showed better differentiation capabilities than existing metrics like APV (Array Pulse Volume) and 2DL (from contour analysis) for distinguishing taut and slippery pulses, particularly by retaining spatial information.

Limitations and Future Work

  • Subject Demographics: The study used young, healthy subjects. Taut pulses were induced by CPT, not collected from naturally hypertensive patients. Future work should collect data from patients with various ages and hypertension conditions to validate the statistical recognition rate.
  • Pulse Types: The current study focused on normal, taut, and slippery pulses. Future research could extend this analysis to other TCM pulse types.
  • Alternative Methods: While Fourier series proved effective, the authors suggest exploring other signal processing techniques like Wavelet Transform (WT) and Hilbert-Huang Transform (HHT) to further investigate spatiotemporal characteristics.
  • Broader Application: The goal is to translate TCM pulse feelings into quantifiable metrics, which could have broader applications in non-invasive health monitoring and diagnosis.

Summary updated

Abstract

In this article, a three-dimensional pulse image (3DPI) instead of a one-dimensional temporal pulse wave is studied to elucidate its spatiotemporal characteristics. To check the spatial and temporal properties of 3DPI, adopted is Fourier series, in which a ratio (<i>r</i>) is defined as one amplitude divided by the sum of the first three amplitudes of harmonics. A ratio sequence is constituted from 70 to 90 ratios in a heartbeat with 70-90 3DPIs by sampling. Twenty-four subjects (14 males and 10 females with age of 22.2 ± 3.7 years, 20.4 ± 1.4 BMI, and 112.1 ± 4.7 mmHg systolic blood pressure) are involved in this research. There are significant statistical differences in the groups of the normal, taut, and slippery 3DPIs by the first harmonic ratio average ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mover> <mml:mrow> <mml:msub><mml:mrow><mml:mi>r</mml:mi></mml:mrow> <mml:mrow><mml:mn>1</mml:mn></mml:mrow> </mml:msub> </mml:mrow> <mml:mo>¯</mml:mo></mml:mover> </mml:mrow> </mml:math> ) and ratio difference (Δ<i>r</i> <sub>1</sub>) produced from the ratio sequence. The proposed method of this study gives us a novel viewpoint to clarify the spatiotemporal characteristics of pulse images, which can translate and quantize the pulse feeling in Chinese medicine texts.
BibTeX
@inproceedings{peng2019fourier,
  author = {Bo Peng and Ching‐Hsing Luo and Nilotpal Sinha and Cheng‐Chi Tai and Xiaohua Xie and Haiqing Xie},
  title = {{Fourier Series Analysis for Novel Spatiotemporal Pulse Waves: Normal, Taut, and Slippery Pulse Images}},
  booktitle = {Evidence-based},
  year = {2019},
  doi = {10.1155/2019/5734018},
}

Loading related content...