Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

João Freitas, Warre Snaet, Jan D'hooge, Sandro QueirósarXiv 2026

TL;DR

This paper presents a multi-task deep learning framework for assessing cardiac function by fine-tuning the EchoPrime foundation model. By combining physiologically-aware temporal sampling, attention-based fusion of multiple ultrasound views, and auxiliary supervision from the MIMIC-IV-ECHO dataset, the authors achieved state-of-the-art results in estimating heart health biomarkers for cancer patients.

What Problem Does This Paper Address?

In cardio-oncology, doctors must closely monitor a patient’s heart health, as many cancer treatments can be toxic to cardiac tissue. The standard metric for this is the Left Ventricular Ejection Fraction (LVEF)—a measure of how much blood the heart pumps out with each beat.

However, calculating LVEF from echocardiograms (ultrasound videos) is notoriously difficult. It is highly dependent on the operator's skill, suffers from significant inter-observer variability, and often only reveals damage after it has already become clinically significant. There is a dire need for automated, standardized tools that can detect subtle "Left Ventricular (LV) dysfunction" earlier than traditional methods.

Methods

The authors developed a multi-task pipeline that processes two standard ultrasound views: the Apical four-chamber (A4C) and two-chamber (A2C) views. Their approach consists of four main pillars:

  1. Cardiac Cycle Standardization: Instead of just taking random frames, the team used a pretrained segmentation model (EchoNet-Dynamic) to track the heart's volume over time. They identified the exact start and end of a heartbeat (the cardiac cycle) and sampled a standardized 16-frame clip. This ensures the model always sees a complete "pump" cycle.
  2. Foundation Model Fine-Tuning: They utilized EchoPrime, a massive spatiotemporal foundation model pretrained on over 12 million echocardiography videos. Rather than using it as a static feature extractor, they fine-tuned it end-to-end to adapt its general knowledge to the specific nuances of cardio-oncology.
  3. Attention-based Multi-View Fusion: Since A4C and A2C views provide different perspectives of the heart, the model uses an attention mechanism to "weight" which view is more reliable or informative for a specific patient. It also uses "view-aware" embeddings to help the model distinguish between the two perspectives.
  4. Multi-Task Learning: The model features two "heads": one for regression (predicting the continuous LVEF percentage) and one for classification (identifying binary LV dysfunction). Training on both tasks simultaneously forces the model to learn more robust features.

Datasets

  • EchoRisk: The primary dataset for the MICCAI 2026 challenge, containing longitudinal data from 422 patients and 1,123 examinations.
  • MIMIC-IV-ECHO: An auxiliary dataset used to broaden the distribution of LVEF values during training. The authors used a custom OCR pipeline (GLM-OCR) to extract LVEF measurements from raw DICOM reports to create additional training labels.

Key Insights and Ideas

  • Physiology-Guided Sampling is Crucial: The authors found that standardizing clips based on the actual cardiac cycle (rather than naive uniform sampling) significantly reduced LVEF estimation errors.
  • The "Goldilocks" Weighting for External Data: While adding the MIMIC-IV-ECHO dataset helped, the authors discovered that giving it too much weight biased the model. The best results came from weighting the external data at 0.5 relative to the primary EchoRisk data, treating it as a "complementary" signal rather than a primary one.
  • Synergy Between Tasks: The multi-task approach outperformed models trained on only one task. Predicting continuous LVEF helps the model understand global heart function, while the dysfunction classification task sensitizes the model to specific patterns of clinical deterioration.

Key Results

Evaluated on the EchoRisk-MICCAI Challenge validation set, the framework achieved:

  • LVEF Estimation (Task 1): A Mean Absolute Error (MAE) of 4.003, a significant improvement over the original EchoPrime baseline (6.970) and the challenge baseline (5.020).
  • LV Dysfunction Detection (Task 2): An Area Under the Curve (AUC) of 0.764, outperforming the challenge baseline of 0.755.

Limitations and Future Work

The authors noted that the model is still limited by the scarcity of "positive" cases (patients with actual dysfunction) in the training set. When they trained on the full dataset without early stopping, the AUC for dysfunction improved, but the LVEF regression accuracy dropped, suggesting a trade-off between the two tasks when data is limited.

Future work will likely involve extending this framework to Task 3 of the challenge: predicting future cardiotoxicity from baseline images, which is the "holy grail" of early intervention in cardio-oncology.

Summary updated

Abstract

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.
BibTeX
@misc{freitas2026foundation,
  author = {João Freitas and Warre Snaet and Jan D'hooge and Sandro Queirós},
  title = {{Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment}},
  year = {2026},
  eprint = {2611.18816},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.18816},
}
Figure