Fluxgate effect in twisted magnetic wire

Mattia Butta, Pavel Ripka, S. Atalay, F.e. Atalay, X.p. LiJournal of Magnetism and Magnetic Materials 2008 · DOI

TL;DR

Researchers have developed a novel, coil-less fluxgate magnetometer by twisting a ferromagnetic-coated wire. This innovation significantly miniaturizes fluxgate sensors by eliminating the need for excitation and pickup coils, making them more practical for a wider range of applications.

What Problem Does This Paper Address?

Fluxgate magnetometers are highly precise sensors for measuring magnetic fields, crucial in applications requiring resolutions better than 1 nT. However, traditional fluxgate designs are bulky due to the necessity of excitation and pickup coils. While some advancements have reduced the need for excitation coils, a pickup coil for detecting the sensor's output signal has remained. This paper addresses the challenge of further miniaturizing fluxgate sensors by eliminating all coils, thereby simplifying their construction and enabling more compact designs.

Methods

The core of the novel sensor is a copper wire coated with a ferromagnetic alloy (specifically, polycrystalline Co18.97Ni49.60Fe31.43). The ferromagnetic layer is electrodeposited onto the wire. The key innovation lies in the twisting of this wire. An alternating current is passed through the wire, which saturates the ferromagnetic layer. The output voltage is then measured directly across the wire's terminations. The authors investigated the effect of applying a torque to twist the wire, observing that the second harmonic component of the output voltage is directly related to the external magnetic field. This second harmonic is extracted using a lock-in amplifier. They also explored wires with thinner ferromagnetic layers to reduce saturation current requirements.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Coil-less operation: The most significant insight is that the output signal (specifically, the second harmonic of the voltage) can be directly measured from the wire's terminations, eliminating the need for a separate pickup coil.
  • Helical Anisotropy: The observed effect is attributed to helical anisotropy induced by the mechanical stress from twisting the wire. This anisotropy influences the magnetic properties of the ferromagnetic layer.
  • Twisting Angle Sensitivity: The sensitivity of the sensor to external magnetic fields is strongly dependent on the twisting angle applied to the wire.
  • Directional Sensitivity: Inverting the direction of the twist reverses the sign of the second harmonic response, indicating a clear correlation between mechanical stress and magnetic output.
  • Thinner Layers, Lower Current: Using thinner ferromagnetic layers on the wire significantly reduces the required saturation current, making the sensor more power-efficient and practical.

Key Results

  • The developed coil-less fluxgate exhibits a linear response to external magnetic fields in the range of approximately -100 µT to 100 µT.
  • The sensitivity of the sensor can be adjusted by changing the twisting angle of the wire, with higher angles generally leading to increased sensitivity.
  • A signal whose second harmonic is approximately 3% of the peak-to-peak output voltage can be achieved with a twisting angle of around 20 degrees. This level is considered sufficient for extraction using standard techniques.
  • Wires with thinner ferromagnetic layers (2 µm) require significantly lower saturation currents (7-8 mA at 30 kHz) compared to thicker layers (55 mA at 30 kHz), while still demonstrating a usable signal.
  • The authors note that the sensor's performance can be further improved by using a four-terminal connection for sensing, which minimizes resistive voltage drops.

Limitations and Future Work

  • Irreversible Changes: The authors observed that twisting the wire too much or in alternating directions can lead to irreversible changes in its parameters, likely due to plastic deformation and structural changes. This suggests a need for careful handling and calibration.
  • Saturation Current: While thinner layers reduce the saturation current, it is still a critical parameter. The authors note that the current must be higher than the saturation current ($I_{sat}$) to avoid issues like "perming effect" and ensure a linear response.
  • Contact Resistance: The performance can be limited by the contact resistance at the wire terminations. Future work could focus on materials with lower contact resistance to maximize sensor performance.
  • Future Directions: The authors suggest developing coil-less fluxgates with shorter wires (on the order of millimeters) and incorporating built-in helical anisotropy during the manufacturing process, rather than relying on post-production twisting.

Summary updated

BibTeX
@article{butta2008fluxgate,
  author = {Mattia Butta and Pavel Ripka and S. Atalay and F.E. Atalay and X.P. Li},
  title = {{Fluxgate effect in twisted magnetic wire}},
  journal = {Journal of Magnetism and Magnetic Materials},
  year = {2008},
  doi = {10.1016/j.jmmm.2008.04.176},
}

Loading related content...

Figure