Fluorescent Aptasensor for Highly Specific Detection of ATP Using a Newly Screened Aptamer

Xin Chen, Yangkun Feng, Haohan Chen, Yuting Zhang, Xiaoli Wang, Nandi Zhou2022

TL;DR

Researchers have developed a novel fluorescent aptasensor for highly specific detection of adenosine triphosphate (ATP). This new sensor utilizes a newly screened aptamer that significantly improves discrimination against similar molecules like ADP and AMP, overcoming a key limitation of existing ATP biosensors. The system leverages graphene oxide for initial capture and a clever strand displacement amplification (SDA) strategy for signal enhancement, enabling sensitive and accurate ATP detection in complex biological samples like human serum.

What Problem Does This Paper Address?

Adenosine triphosphate (ATP) is a fundamental molecule in all living cells, serving as the primary energy currency and playing crucial roles in various cellular processes. Consequently, monitoring ATP levels is vital for understanding cellular metabolism, evaluating physiological states, and diagnosing diseases. While various ATP detection methods exist (bioluminescence, chromatography, electrophoresis), they often suffer from high costs, complex equipment requirements, and demanding sample pretreatment. Aptamer-based biosensors offer a promising alternative due to their flexibility, high sensitivity, and good biocompatibility. However, a significant challenge with existing ATP aptamers is their limited ability to differentiate ATP from structurally similar molecules such as adenosine diphosphate (ADP) and adenosine monophosphate (AMP). This lack of specificity hinders accurate assessment of the "energy charge" within cells and can lead to misinterpretations in biological and clinical diagnostics. This paper aims to address this specificity gap by screening and developing a novel aptamer with enhanced discrimination capabilities for ATP.

Methods

The core of this work lies in the development of a fluorescent aptasensor that combines a newly screened, highly specific ATP aptamer with a signal amplification strategy.

  • Aptamer Screening: The researchers employed a magnetic beads-based Systematic Evolution of Ligands by Exponential Enrichment (SELEX) technique. This method was specifically adapted for small molecule targets and involved multiple rounds of selection and counter-screening against ADP and AMP to enrich for ATP-specific sequences.
  • Functional Chimera Sequence Design: A single-stranded DNA sequence was designed to act as the "functional chimera." This sequence incorporated three key regions:
  • The newly screened ATP aptamer at the 5' end for specific ATP recognition.
  • An antisense sequence complementary to a Nb.bpu10I endonuclease cleavage site in the middle.
  • A primer binding region at the 3' end to initiate signal amplification.
  • Graphene Oxide (GO) Adsorption: The functional chimera sequence was initially adsorbed onto graphene oxide (GO) via π-π stacking. This adsorption process quenches the fluorescence of a FAM label attached to the chimera.
  • ATP-Induced Dissociation: Upon binding of ATP to the aptamer region, the conformation of the chimera sequence changes, leading to its dissociation from the GO surface. This dissociation releases the quenched FAM-labeled sequence.
  • Strand Displacement Amplification (SDA): The released chimera sequence serves as a template for a polymerase and endonuclease-based SDA reaction. This process involves:
  • Hybridization with a primer.
  • DNA polymerization by Bsm DNA polymerase to create a double-stranded DNA with the Nb.bpu10I cleavage site.
  • Cleavage by Nb.bpu10I endonuclease.
  • Strand displacement by Bsm DNA polymerase, generating a large number of single-stranded reporter probes.
  • Molecular Beacon Signal Recovery: A molecular beacon, labeled with a FAM fluorophore and a dabcyl quencher, is introduced. The reporter probes generated during SDA hybridize with the molecular beacon, opening its hairpin structure and restoring the FAM fluorescence. The intensity of this recovered fluorescence is directly proportional to the amount of ATP present.
  • Characterization: Techniques like Polyacrylamide Gel Electrophoresis (PAGE) and fluorescence spectroscopy were used to verify the principle of the aptasensor and the successful execution of each step.

Datasets

Not discussed in the paper. The study focuses on the development and validation of a new aptasensor using synthesized DNA sequences and biological samples (human serum).

Key Insights and Ideas

  • Overcoming Aptamer Specificity Limitations: The most significant insight is the successful screening of a novel aptamer that demonstrates markedly improved specificity for ATP over ADP and AMP. This directly addresses a critical bottleneck in existing ATP biosensors.
  • Synergistic Signal Amplification: The combination of GO-mediated signal quenching, ATP-induced release, and SDA provides a powerful multi-stage amplification mechanism, leading to enhanced sensitivity.
  • Integrated Detection Strategy: The design cleverly integrates target recognition (aptamer), signal transduction (GO dissociation), and signal amplification (SDA) into a single, cohesive fluorescent assay.
  • Molecular Beacon as a Robust Readout: The use of a molecular beacon provides a clear and quantifiable fluorescent signal that is directly correlated with the amplified reporter probe concentration.

Key Results

  • High Affinity Aptamer: The newly screened aptamer exhibits a dissociation constant (Ka) of 70.61 ± 20.91 nM, indicating a higher affinity for ATP compared to the classic ATP aptamer.
  • Improved Specificity: The aptamer showed 2.4 and 4.7-fold higher binding affinity for ATP compared to ADP and AMP, respectively, with statistically significant differences. This is a substantial improvement over the classic aptamer, which showed nearly identical affinities for these molecules.
  • Linear Detection Range: The fluorescent intensity of the aptasensor was linearly related to ATP concentration within the range of 0.1 µM to 25 µM under optimal conditions.
  • Low Detection Limit: The aptasensor achieved a detection limit of 33.85 nM (signal-to-noise ratio of 3).
  • Serum Sample Analysis: The aptasensor demonstrated good performance in detecting ATP in diluted human serum samples, with recovery rates between 98.745% and 104.676% and relative standard deviations (RSD) between 1.978% and 2.961%, indicating its potential for real-world applications.

Limitations and Future Work

  • Residual Affinity for Analogs: While significantly improved, the aptamer still exhibits a low affinity for ADP and AMP. The authors acknowledge that achieving complete discrimination is challenging due to the similar structures of these adenylate derivatives.
  • Serum Dilution: For serum samples, a 10-fold dilution was required. While the serum itself had a negligible impact, further investigation into direct detection in undiluted serum might be beneficial.
  • Future Work: The authors suggest that the screened aptamer and the developed biosensor have promising applications in evaluating the real energy charge level and ATP content in complex biological systems. Further work could focus on optimizing the aptamer for even greater specificity or exploring its use in other detection platforms.