FlowersBench: A FluidFlower-Inspired Dataset for Benchmarking Carbon Storage Surrogates Across Geological Structures

Farah Rabie, Hannah Menke, Florian Doster, Amy Gough, Ahmed H. ElsheikharXiv 2026

TL;DR

Predicting how injected $\text{CO}_2$ moves underground requires painfully slow physics simulations, prompting researchers to train fast machine learning "surrogates" as stand-ins. Until now, benchmarks for these ML models mostly tested them on a single, fixed underground rock structure—akin to testing a self-driving car on just one road layout with varying weather. FlowersBench introduces 5,000 simulations across hundreds of distinct, faulted rock geometries to finally test whether ML surrogates can generalize to underground architectures they have never seen before.

What Problem Does This Paper Address?

To store carbon dioxide safely underground—a pillar of large-scale decarbonization—engineers have to predict how a buoyant $\text{CO}_2$ plume will migrate over centuries. Because mapping the deep Earth with seismic waves is notoriously fuzzy, we never know the exact layout of underground rock layers and faults. Quantifying this uncertainty requires running thousands of multiphase fluid-flow simulations, which is computationally grueling.

Machine learning surrogates can approximate these simulations in milliseconds. However, existing benchmark datasets only vary rock properties (like porosity or permeability) and well locations while holding the overarching geological structure—the arrangement of rock layers and faults—completely fixed. If you deploy an ML model on a new candidate storage site, its underground architecture won't match your training data. How well do surrogates actually handle unseen geological structures? Until now, we didn't have the dataset to find out.

Methods

The authors built a four-stage procedural pipeline to generate synthetic, physically grounded storage scenarios, pairing it with a baseline deep learning model.

Figure 1: Four-stage workflow used to generate FlowersBench: geometric realisation, property assignment, well placement, and case simulation in OPM Flow.
  • Novel Procedural Structure Generation: Instead of perturbing a single map, an in-house stochastic generator builds diverse 2D cross-sections ($8.4\text{ km} \times 1.2\text{ km}$) from scratch. It stacks sinusoidal rock layers and slices them with finite-thickness faults—creating single faults, grabens (lowered central blocks), and raised central blocks.
  • Property & Well Sampling: Regions are classified into permeable reservoirs, low-permeability seals, fault damage zones (which can act as fluid highways), and fault cores (which can seal or leak). A single injection well is stochastically placed in deeper, permeable layers.
  • Standard Physics Simulation: Each setup is run in Open Porous Media (OPM) Flow following the established SPE11B physics formulation: 50 years of $\text{CO}_2$ injection followed by 500 years of post-injection monitoring, tracking thermal effects, dissolution, and trapping.
  • Baseline Surrogate: A standard 2D U-Net with a residual bottleneck takes five downsampled ($256 \times 64$) static/initial fields (porosity, permeability, well mask, initial pressure, and initial temperature) and predicts $\text{CO}_2$ gas saturation across all 17 time steps in one shot. Its training combines stage-weighted Mean Squared Error with an edge-weighted loss to sharpen steep saturation fronts.
Figure 3: Fault styles sampled by the in-house structural generator: (a) a single fault, (b) a fault pair with a raised central block, and (c) a fault pair with a lowered central block (graben). Fault damage zones are shown in purple and fault cores in a darker shade. Coordinates as in Figure 2.

Datasets

The paper introduces FlowersBench (~56 GB, publicly available), inspired by the lab-scale FluidFlower experiments and reservoir-scale SPE11B benchmark. Unlike SPE11B's single geometry, FlowersBench spans hundreds of distinct architectures:

  • Main Dataset: 5,000 simulations across 244 structural geometries (doubled to 10,000 samples via horizontal reflection). Crucially, train/validation/test splits are divided by geometry, ensuring test structures are genuinely unseen.
  • Extended-Range Subset (Structural Shift 1): 50 simulations (18 geometries) pushing generator parameters outside training bounds—featuring thinner, flatter, more numerous layers and wider fault pairs.
  • Parallel-Fault Subset (Structural Shift 2): 50 simulations (18 geometries) built with a separate generator introducing an entirely unseen fault topology: 2 to 4 parallel faults slicing rock into a staircase of offset blocks.

Key Insights and Ideas

  • Topology breaks surrogates much harder than parameter stretching: When rock layers simply get thinner or faults get wider (Extended-Range), the surrogate's error increases in magnitude, but its behavior over time stays stable. When faced with a brand-new fault arrangement (Parallel-Fault), the predicted and true $\text{CO}_2$ footprints steadily diverge over centuries as buoyancy drives gas through unfamiliar pathways.
  • Physics takes centuries to diverge: Even after injection stops at year 50, differences in plume extent across simulations keep widening for hundreds of years as geological structures redirect buoyant $\text{CO}_2$. A surrogate can't just memorize near-well injection; it has to respect long-term structural trapping.
  • Subtle temporal biases: On unseen in-distribution geometries, the baseline U-Net systematically over-predicts $\text{CO}_2$ saturation during active injection, then flips to under-predicting it during centuries of post-injection migration.

Key Results

  • Speedup: A full OPM Flow simulation takes ~40 minutes (ranging from 29 to 93 minutes) on 16 CPU threads. Once trained (~45 minutes on a single TITAN RTX GPU), the U-Net predicts the downsampled 550-year saturation sequence in ~0.015 seconds on an 18-core CPU.
  • In-Distribution Accuracy: On held-out geometries from the main generator, the U-Net captures complex lateral spreading beneath seals and upward fault migration. Plume-masked Mean Absolute Error ($\text{MAE}$) averages 0.066, signed bias is $-0.002$, and relative $L_2$ error is 0.26, with errors tightly concentrated along steep plume boundaries.
  • Structural Shift Degradation: Under parameter-range shift (Extended-Range), mean plume-masked $\text{MAE}$ rises to 0.094 and relative $L_2$ error to 0.38. Under topological shift (Parallel-Fault), $\text{MAE}$ is similar (0.091), but the model systematically over-predicts saturation, and relative $L_2$ error climbs relentlessly after injection stops—reaching 0.98 at year 550.

Limitations and Future Work

  • 2D Procedural Idealization: The generator is strictly 2D and procedural; it omits 3D fluid pathways, curved or branching fault networks, and erosional unconformities, and isn't calibrated to field seismic interpretations.
  • Fixed Operational & Physics Scope: Every simulation uses a single well, a fixed injection rate, and one simulator without geomechanical coupling (so fault reactivation or caprock fracturing from pressure buildup isn't modeled).
  • Baseline Constraints: Downsampling to $256 \times 64$ blurs thin layers and fault cores down to 1–2 pixels, and the structural-shift subsets change multiple geological factors at once. Future work includes 3D extensions, single-factor shift subsets, varying well schedules, predicting pressure and dissolved $\text{CO}_2$, and testing graph neural networks that encode structural geometry directly.

Summary updated

Abstract

Machine learning surrogates are emerging as a computationally efficient tool for uncertainty quantification in geological carbon storage (GCS). Geological structure constitutes a major source of uncertainty; however, existing benchmark simulation datasets predominantly vary petrophysical and operational parameters within a fixed geological setting. Generalisation to unseen geological structures therefore remains largely unexplored. We introduce FlowersBench, a benchmark dataset of 5,000 two-dimensional, reservoir-scale CO$_2$ storage simulations across 244 structural geometries. The geometries are sampled from an in-house structural generator inspired by the FluidFlower experiments and Case B of the 11th Society of Petroleum Engineers Comparative Solution Project (SPE11B). Each simulation is run with Open Porous Media (OPM) Flow over a 50-year injection period and a 500-year post-injection monitoring period. Test geometries are withheld from training to assess generalisation to unseen structural geometries. Two additional subsets support evaluation under structural shift. The first extends the parameter ranges of the structural generator beyond those used for training, and the second introduces an unseen topology of multiple parallel faults. A baseline U-Net surrogate is trained to predict CO$_2$ gas saturation. In representative test cases, the surrogate recovers the main migration pathways, including lateral spreading beneath low-permeability layers and upward flow along fault damage zones, with errors concentrated near the plume boundary. Under both structural shifts, prediction error exceeds that on the held-out geometries, and the increase in relative error is greater for the unseen fault topology. FlowersBench is publicly available and provides a common basis for evaluating GCS surrogates across geological structures.
BibTeX
@misc{rabie2026flowersbench,
  author = {Farah Rabie and Hannah Menke and Florian Doster and Amy Gough and Ahmed H. Elsheikh},
  title = {{FlowersBench: A FluidFlower-Inspired Dataset for Benchmarking Carbon Storage Surrogates Across Geological Structures}},
  year = {2026},
  eprint = {2611.33335},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.33335},
}
Figure