Five-year outcomes of EVO implantable collamer lens implantation for the correction of high myopia and super high myopia

Xun Chen, Xuanqi Wang, Yilin Xu, Mingrui Cheng, Tian Han, Lingling Niu, Xiaoying Wang, Xingtao ZhouEye 2021

TL;DR

This study investigates the long-term (5-year) safety, efficacy, and predictability of EVO implantable collamer lens (ICL) implantation for correcting high myopia (HM) and super high myopia (SHM). The findings indicate that EVO ICL is a safe and effective option for these severe myopia cases, with significant improvements in visual acuity, though axial length growth remains a consideration.

What Problem Does This Paper Address?

Myopia, particularly high myopia (HM, -6 to -12 D) and super high myopia (SHM, worse than -12 D), affects a significant portion of the population, especially in China. While refractive surgery and implantable lenses are common for low to moderate myopia, there's a greater concern and less long-term data for correcting these severe forms of myopia. Patients with HM and SHM often experience reduced self-confidence and limited career choices due to their vision. This study aims to provide robust 5-year data on the EVO ICL, a specific type of intraocular lens, to address the long-term safety, efficacy, predictability, and stability of this procedure for HM and SHM patients. The authors hypothesize that SHM patients might see greater visual acuity improvements due to poorer baseline vision, but also face a higher risk of axial elongation.

Methods

This was a prospective study involving 83 eyes from 46 patients who underwent EVO ICL implantation. Patients were categorized into two groups based on their spherical equivalent (SE): HM group (-12 D < SE < -6 D) and SHM group (SE < -12 D). The study followed these patients for five years post-implantation. Key assessments included:

  • Visual Acuity: Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were measured.
  • Refractive Error: Manifest refractive error and spherical equivalent (SE) were tracked.
  • Ocular Biometry: Axial length, intraocular pressure (IOP), corneal endothelial cell density, and vault (the space between the ICL and the natural lens) were measured.
  • Patient Satisfaction: A questionnaire was administered to gauge patients' self-image, confidence, career impact, convenience, and overall satisfaction with the procedure.

Statistical analyses included repeated measures ANOVA and t-tests to compare outcomes between the HM and SHM groups.

Datasets

Not applicable. This study involved prospective data collection from patients undergoing a surgical procedure. No pre-existing datasets were used for training or evaluation.

Key Insights and Ideas

  • Long-Term Safety and Efficacy Confirmed: The 5-year follow-up data strongly supports the safety and efficacy of EVO ICL for both HM and SHM. The safety indices remained consistently above 1.00 throughout the study period.
  • SHM Patients Show Greater CDVA Improvement: While both groups benefited, SHM patients experienced a more pronounced improvement in corrected distance visual acuity (CDVA), likely due to their significantly poorer preoperative vision.
  • Axial Length Growth is a Persistent Concern: A key finding is the continued, albeit slow, growth in axial length in both groups, particularly more pronounced in the SHM group. This suggests that while ICL corrects the refractive error, it doesn't halt the underlying progression of myopia, which is often linked to axial elongation.
  • Predictability Declines Over Time: While predictability was good at 1 month post-surgery, there was a tendency towards undercorrection at 5 years, more so in the SHM group. This "myopic drift" is attributed to the ongoing progression of myopia.
  • Patient Satisfaction is High: The questionnaire results revealed high levels of satisfaction across both groups, with patients reporting improved self-image, confidence, and convenience. The impact on careers was also noted, particularly in the SHM group.

Key Results

  • Safety Indices: At 5 years post-surgery, safety indices were 1.03 ± 0.10 for HM and 1.32 ± 0.39 for SHM.
  • Efficacy Indices: At 5 years post-surgery, efficacy indices were 0.83 ± 0.25 for HM and 0.86 ± 0.32 for SHM.
  • Refractive Correction: At 5 years, 60.47% of HM eyes and 22.50% of SHM eyes were within ±0.50 D of the attempted correction.
  • Spherical Equivalent (SE) Change: In the HM group, SE changed from -9.72 ± 1.41 D preoperatively to -0.67 ± 0.57 D at 5 years. In the SHM group, SE changed from -15.78 ± 3.06 D preoperatively to -1.74 ± 1.19 D at 5 years.
  • Axial Length Growth: The HM group showed an average axial length increase of 0.16 ± 0.21 mm over 5 years, while the SHM group showed an increase of 0.39 ± 0.29 mm.
  • Endothelial Cell Loss: Mean endothelial cell loss rates were 3.66% for HM and 3.20% for SHM over 5 years, with no significant difference between groups.
  • Patient Satisfaction: Over 87% of patients in both groups reported positive responses to questions about self-image, confidence, and convenience.

Limitations and Future Work

The authors acknowledge several limitations:

  • Small Sample Size: The statistical power might be limited due to the relatively small number of participants.
  • Lack of Comparison Groups: The study did not include a comparison group for low to moderate myopia or a direct comparison of visual quality metrics.
  • Limited Follow-up Data Points: The study primarily focused on three time points (preoperative, 1 month, and 5 years), with intermediate data not fully analyzed due to the COVID-19 pandemic.
  • Axial Length Growth: The study highlights the need for continued attention to axial length growth, especially in SHM patients, as it can lead to further myopia progression and reduced visual acuity.

Future research could focus on longer-term follow-up to fully understand the trajectory of axial length growth and its impact. Investigating strategies to mitigate this progression, or comparing EVO ICL outcomes with other advanced refractive correction methods over extended periods, would also be valuable.