First‐trimester ultrasound detection of fetal heart anomalies: systematic review and meta‐analysis

J. Karim, Elizabeth Bradburn, Nia Roberts, Aris T. Papageorghiou, for the Accepts studyUltrasound 2021 · DOI

TL;DR

This systematic review and meta-analysis of over 328,000 fetuses demonstrates that first-trimester ultrasound can detect over half of major fetal cardiac anomalies. Crucially, adopting structured anatomical assessment protocols, including outflow tract views and color-flow Doppler, significantly improves detection rates, paving the way for earlier and more effective prenatal screening.

What Problem Does This Paper Address?

Congenital heart abnormalities are the most common structural malformations in newborns, carrying significant mortality and morbidity. While second-trimester ultrasound is the current standard for prenatal diagnosis, a substantial number of these anomalies are still missed. Early detection in the first trimester (11-14 weeks) is highly desirable as it can inform prenatal decision-making, genetic counseling, and potentially improve outcomes. However, there's a lack of international consensus on how to best perform this early cardiac assessment, leading to variable detection rates. This paper aims to clarify the diagnostic accuracy of first-trimester ultrasound for fetal cardiac anomalies and identify factors that influence its effectiveness.

Methods

The authors conducted a systematic review and meta-analysis of published studies evaluating the diagnostic accuracy of first-trimester ultrasound for fetal cardiac anomalies. They searched four major databases for studies published between January 1998 and July 2020. Two independent reviewers selected eligible studies, and data were extracted to populate 2x2 tables. A random-effects model was used for meta-analysis to determine pooled sensitivity, specificity, and positive predictive values. They specifically analyzed data for both high-risk and non-high-risk populations and conducted pre-planned secondary analyses to assess the impact of various factors on screening performance. These factors included the imaging protocol used (e.g., four-chamber view only, addition of outflow tracts, use of color-flow Doppler), ultrasound modality (transabdominal vs. transvaginal), publication year, and the sonographer's index of suspicion. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to assess the risk of bias and quality of included studies.

Datasets

The study is a meta-analysis of existing data from 63 published studies, encompassing a total of 328,262 fetuses. No new datasets were created or introduced.

Key Insights and Ideas

  • Early detection is feasible and impactful: Over half of major cardiac anomalies can be identified in the first trimester, offering a crucial window for intervention and management.
  • Protocol matters immensely: The level of detail in the ultrasound examination protocol is a significant driver of detection rates. More comprehensive protocols lead to better outcomes.
  • Outflow tracts and color Doppler are game-changers: Including outflow tract views and color-flow Doppler imaging, in addition to the standard four-chamber view, dramatically improves the sensitivity of first-trimester cardiac screening.
  • High-risk vs. low-risk: While detection rates are higher in high-risk populations, the study shows that even in unselected (non-high-risk) populations, a substantial number of anomalies can be found with appropriate techniques.
  • Not all anomalies are equal: Some cardiac defects are inherently harder to detect in the first trimester due to their nature or size, suggesting that first-trimester screening should focus on anomalies that significantly impact prenatal decision-making.

Key Results

  • Overall Sensitivity: First-trimester ultrasound achieved a pooled sensitivity of 55.80% in the non-high-risk population and 67.74% in the high-risk population for detecting major cardiac anomalies.
  • Specificity and PPV: Specificity was very high (99.98% and 99.75% respectively), and positive predictive values were also strong (94.85% and 94.22% respectively), indicating that a positive screen is highly likely to represent a true anomaly.
  • Impact of Imaging Protocol: Studies using more detailed protocols (e.g., four-chamber view + outflow tracts + color-flow Doppler) showed significantly higher detection rates (up to 80% in non-high-risk groups) compared to those using only the four-chamber view.
  • Contribution to Antenatal Diagnosis: First-trimester detection accounted for approximately 64% of all antenatally diagnosed major cardiac anomalies in the non-high-risk group and 80% in the high-risk group.

Limitations and Future Work

  • Reporting Bias: The authors acknowledge that studies might be subject to reporting bias, with centers of excellence potentially showing higher rates than what might be achievable in routine practice.
  • False-Positive Rate Uncertainty: Determining the exact false-positive rate is challenging because early termination of pregnancy can preclude postmortem confirmation. The study estimates it to be low (around 2.1% in the non-high-risk group for diagnosed/suspected cases), but calls for clearer reporting of reference tests in future studies.
  • Heterogeneity: While efforts were made to mitigate heterogeneity between studies, variations in inclusion/exclusion criteria, sonographer experience, and postnatal follow-up remain.
  • Future Work: The authors emphasize the need for standardized anatomical assessment protocols, including outflow tract views and color-flow Doppler, for future first-trimester screening programs. They also highlight the importance of developing clear information and support for parents following a positive screening result. Further research should focus on comprehensive reporting of reference tests to improve the accuracy of false-positive rate estimations.

Summary updated

Abstract

First-trimester ultrasound examination of the fetal heart allows identification of over half of fetuses affected by major cardiac pathology. Future first-trimester screening programs should follow structured anatomical assessment protocols and consider the introduction of outflow-tract views and color-flow Doppler imaging, as this would improve detection rates of fetal cardiac pathology. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
BibTeX
@inproceedings{karim2021firsttrimester,
  author = {J. Karim and Elizabeth Bradburn and Nia Roberts and Aris T. Papageorghiou and for the ACCEPTS study},
  title = {{First‐trimester ultrasound detection of fetal heart anomalies: systematic review and meta‐analysis}},
  booktitle = {Ultrasound},
  year = {2021},
  doi = {10.1002/uog.23740},
}
Figure