TL;DR
Brookhaven National Laboratory (BNL) is commissioning a new superconducting Energy Recovery Linac (ERL) designed for high-current electron beams. This paper reports the initial test results of the SRF photoinjector, a crucial component for generating these beams, demonstrating its capability for CW operation and initial dark current measurements. These results are vital for advancing technologies for future high-energy physics experiments and advanced light sources.
What Problem Does This Paper Address?
The development of high-current, high-brightness electron beams is a critical challenge for next-generation accelerators, including those for coherent electron cooling, electron-ion colliders, and Free Electron Lasers (FELs). Energy Recovery Linacs (ERLs) offer a promising path to achieve these goals due to their potential for high beam currents and efficient energy recovery. However, realizing such ERLs requires robust and high-performance components, particularly the electron source (photoinjector) and the accelerating structures. BNL is building a research and development (R&D) ERL to test these critical concepts. This paper focuses on the initial commissioning and performance of the SRF photoinjector, a key element designed to produce a 2 MeV, 300 mA average current electron beam, which is essential for the overall ERL's success.
Methods
The paper details the design and initial testing of the SRF photoinjector for the BNL R&D ERL. The core components include a 704 MHz superconducting radio frequency (SRF) gun with a multi-alkali photocathode and a novel low-energy merger system designed for emittance preservation. The SRF gun itself is a short, 8.5 cm cell design with a large iris radius (5 cm) to facilitate Higher Order Mode (HOM) damping. The commissioning process involved testing the SRF gun under continuous wave (CW) operation, both with and without the cathode installed, and performing initial beam diagnostics. Techniques employed include measuring beam-line vacuum, gun voltage, dark current using a Faraday cup and YAG crystal, and estimating beam energy.
Datasets
Not discussed in the paper. The paper focuses on experimental results from the commissioning of the SRF photoinjector at BNL.
Key Insights and Ideas
- SRF Gun Achieves CW Operation: The 704 MHz SRF gun has successfully demonstrated CW operation at 1.2 MV, a crucial step towards achieving the target beam current.
- Dark Current Reduction: Conditioning the SRF gun significantly reduced dark current by a factor of 25, which is vital for maintaining beam quality and minimizing unwanted beam interactions.
- Vacuum Stability Challenges: Initial tests revealed vacuum spikes during RF power application with the cathode inserted, highlighting a potential issue that could impact photocathode performance and overall beam quality.
- Thermal Limitations in the Linac: A thermal problem was identified in the 5-cell SRF linac, currently limiting CW operation to gradients below ~12 MV/m. This necessitates exploring pulsed or "quasi-CW" operation modes for the linac.
- Importance of HOM Damping: The design of the SRF gun incorporates features like a large iris radius and external dampers to manage HOMs, which is critical for the stability of high-current beams in ERLs.
Key Results
- The SRF gun has been commissioned and routinely operates CW without the cathode at 2 MV accelerating voltage.
- With the cathode stalk installed, the gun operated at 1.8 MV voltage pulses for 120 ms every second.
- After additional conditioning, the gun demonstrates CW operation at 1.2 MV.
- Initial dark current measurements showed a reduction of 25 times after conditioning.
- Dark current was measured at 1.4 µA at a cathode field of 15 MV/m.
- The 5-cell SRF cavity has been commissioned and achieved high gradients for short periods, but CW operation is limited by thermal issues.
Limitations and Future Work
The authors acknowledge a thermal problem in the 5-cell SRF linac that currently prevents CW operation at higher gradients. This limitation means that the prototype program will proceed with pulsed or "quasi-CW" operation of the linac. Future work includes continuing low-power beam tests with a new cathode, avoiding low-voltage operation to mitigate multipacting and vacuum degradation, and implementing the solenoid for cathode imaging. The installation of the ERL 1MW beam dump and extraction line magnets is also planned. The ultimate goal is to demonstrate energy recovery with high charge per bunch and high beam current once the recirculation loop is completed.