TL;DR
This study presents field measurements of the Shanghai World Financial Center's (SWFC) wind-induced responses during Super Typhoon Lekima. By analyzing acceleration data, the researchers investigated how natural frequencies and damping ratios change with vibration amplitude and wind speed, revealing important insights into the dynamic behavior of super-tall buildings under extreme wind events.
What Problem Does This Paper Address?
Super-tall buildings, due to their height and lightweight construction, are highly susceptible to wind loads. Understanding their dynamic response to extreme wind events like typhoons is crucial for ensuring structural safety, occupant comfort, and cost-effective design. While wind tunnel tests and numerical simulations are common, field measurements offer the most accurate data. However, comprehensive studies on the dynamic characteristics of super-tall buildings under strong typhoon conditions, particularly how parameters like natural frequency and damping change with amplitude and wind speed, are limited. This paper aims to fill this gap by providing detailed analysis of the SWFC's response to Super Typhoon Lekima.
Methods
The study utilized data from a health monitoring system installed on the SWFC, which included accelerometers and anemometers. The core of the analysis involved two methods for identifying structural dynamic parameters:
- Curve Method: This method involved modal decomposition of acceleration responses, followed by using the Hilbert-Huang Transform (HHT) to find the envelope of modal timescales. Free vibration decay curves were then fitted to obtain natural frequencies and damping ratios.
- Standard Deviation Method: Similar to the curve method, this approach also used modal decomposition. However, it employed the standard deviation of acceleration responses as an interception threshold to identify zero points and then fitted decay curves to extract dynamic parameters.
Both methods were used to analyze the amplitude dependence of natural frequencies and damping ratios, as well as their correlation with mean wind speed. Mode shapes were also identified using a frequency domain approach (FDA).
Datasets
The primary dataset used in this study consists of acceleration measurements collected from the Shanghai World Financial Center (SWFC) over a 72-hour period during Super Typhoon Lekima (from 0:00 on August 8, 2019, to 0:00 on August 11, 2019). Wind speed and direction data from an anemometer at the top of the SWFC were also utilized.
Key Insights and Ideas
- Amplitude-Dependent Dynamics: The study highlights that the natural frequencies of the SWFC decrease as vibration amplitudes increase, while damping ratios increase. This non-linear behavior is attributed to factors like steel joint slippage and increased interaction between structural and non-structural elements under larger displacements.
- Wind Speed Correlation: Natural frequencies exhibit a negative correlation with mean wind speed (decreasing as wind speed increases), whereas damping ratios show a positive correlation (increasing with wind speed). This suggests that stronger winds not only excite the structure more but also tend to increase its energy dissipation capabilities.
- Methodological Comparison: The curve method and standard deviation method yielded comparable results for natural frequencies, but the curve method showed less dispersion. For damping ratios, the methods differed more, with the standard deviation method exhibiting greater fluctuation.
- Consistent Mode Shapes: The mode shapes of the SWFC were found to be remarkably consistent across different typhoons (Lekima, Ampil, Rumbia, and Jongdari), indicating a stable dynamic characteristic of the building. The mode shapes also showed a nonlinear trend with increasing floor level.
Key Results
- Acceleration Levels: The maximum acceleration recorded in the Y-direction was 3.518 cm/s², and in the X-direction was 2.602 cm/s². These values were well within the limits specified by design codes, indicating the building's structural integrity during the typhoon.
- Natural Frequencies: The first-order natural frequencies were approximately 0.151 Hz (X-direction) and 0.153 Hz (Y-direction). The second-order natural frequencies were around 0.46 Hz for both directions.
- Damping Ratios: The first- and second-order damping ratios were generally less than 1%, which the authors suggest might be influenced by the active tuned mass dampers installed in the building.
- Frequency Decrease: The maximum decrease in natural frequency observed was 5.794% (for the first-order natural frequency in the Y-direction).
- Damping Increase: The maximum increase in damping ratio was 95.7% (for the second-order damping ratio in the Y-direction).
Limitations and Future Work
- Non-Gaussian Nature: The paper notes that the second-order damping ratio in the X-direction showed an unexpected trend, possibly due to the non-Gaussian nature of the original acceleration signals.
- Methodological Differences: While both methods for parameter identification were effective, the paper points out differences in their dispersion and sensitivity to amplitude variations, suggesting further investigation into their strengths and weaknesses.
- Future Work: The authors imply that the findings provide valuable data for developing more accurate empirical models for wind-resistant design of super-tall structures. Further research could focus on refining these models and exploring the influence of other factors on the dynamic response.
Summary updated