Feed-Forward Adaptive Gaussian Splatting for Interactive Medical Volume Rendering

Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Chaoyi Zhou, Terrence Chen, Ziyan WuarXiv 2026

TL;DR

Looking inside the human body with realistic, cinema-grade 3D lighting usually forces doctors to wait every time they rotate the view, slice into an organ, or tweak tissue transparency. RenderFM-Next solves this lag by converting raw CT and MRI scans into adaptive 3D "blobs" (Gaussian splats) in a single, one-second pass. By smartly concentrating tiny, high-resolution blobs only along delicate boundaries and virtual slice planes, it delivers crisp, interactive medical visualizations at blazing-fast speeds over 160 FPS.

What Problem Does This Paper Address?

When radiologists inspect 3D CT or MRI volumes, "cinematic" path-traced rendering—which simulates how light bounces and scatters through tissue—helps convey depth and subtle anatomy. The catch? Path tracing is a Monte Carlo estimation that restarts from scratch whenever the user moves the camera, slides a clipping plane (a virtual knife to peer inside organs), or adjusts the transfer function (TF) (the lookup rule mapping raw scan intensities to colors and opacities, like highlighting bone vs. blood vessels).

Recently, 3D Gaussian Splatting—representing scenes as clouds of semi-transparent 3D ellipsoids that rasterize in milliseconds—offered a fast stand-in. While fitting Gaussians to a new patient scan from scratch takes minutes, a prior "feed-forward" neural network called RenderFM learned to predict Gaussians directly from a volume in seconds. However, RenderFM had four major roadblocks:

  1. It only worked on CT scans, ignoring MRIs.
  2. It baked the TF into the network input, forcing a slow re-run of the heavy 3D U-Net every time a user tweaked colors or opacity.
  3. It lacked an exact clipping operator, leaving jagged edges when slicing through tissue.
  4. It placed Gaussians on a rigid 3-mm grid—wasting compute on uniform tissue while blurring thin blood vessels and sliced organ faces (whereas a finer 1.5-mm grid everywhere would require $8\times$ as many Gaussians).
Figure 1. Adaptive refinement for feed-forward medical Gaussians. (a) RenderFM [17] uses a fixed 3-mm grid, which blurs organ boundaries and cut faces. (b) RenderFM-Next, one CT+MR model, refines to 1.5-mm children (orange) where a learned score expects the most benefit, under a user-set budget. Right: clipped clinical presets (validation; RenderFM retrained; PSNR in dB).

Methods

RenderFM-Next splits volume rendering into a one-time preparation phase and an ultra-fast interactive rendering phase.

Figure 2. Overview of RenderFM-Next. Once per volume, one U-Net for CT and MR predicts 3-mm parent Gaussians (green), up to eight 1.5-mm children per parent (orange) and a score that ranks the parents (blue). At render time, the top-K parents under the budget ρ and those next to the clipping plane H are replaced by their children. Bottom: training stages.
  • One Joint CT+MR Network: A single 3D U-Net processes both CT and MRI scans. It knows what kind of scan it is looking at (e.g., CT, T1 MRI, T2 MRI) via FiLM (Feature-wise Linear Modulation) conditioning layers that scale and shift internal features. Crucially, neither the TF nor the clipping plane is fed into this U-Net, so it runs once per patient volume.
  • Coarse-to-Fine Adaptive Refinement: For every 3-mm grid cell, the network predicts a coarse "parent" Gaussian alongside up to eight 1.5-mm "children" Gaussians predicted as residual corrections. When refined, children replace their parent rather than stacking on top, preventing double-counted opacity.
  • Two-Stage Score Learning: To let users dial a compute budget $\rho$ (the fraction of parents refined) at render time without retraining, the authors first train the renderer while randomly refining 10%–50% of parents. Next, they freeze the renderer, set switches to half-opacity ($0.5$), and measure the exact gradient of rendering error for every parent. A lightweight MLP (score head) learns to predict this error-reduction benefit from local features. At render time, the top-scoring parents—plus a mandatory 3-mm cut band right along any active clipping plane—are swapped for sharp 1.5-mm children.
  • Plug-and-Play Appearance & Slicing: Rather than reinventing the wheel, RenderFM-Next pairs its geometry with two recent tools: FactorSplat (a tiny MLP head that updates Gaussian colors/opacities in milliseconds upon TF edits, augmented here with a Beer-Lambert physical opacity prior for MRI) and XClipGS (which mathematically slices Gaussians cleanly along clipping planes).

Datasets

The authors introduce a comprehensive CT+MR Rendering Benchmark totaling nearly 2,000 scans with $1600 \times 1600$ denoised path-traced reference images across clinical presets, TF edits, and clipped views:

  • CT (1,008 scans): Sourced from TotalSegmentator.
  • MRI (958 scans): Spanning head, spine, knee, heart, and abdomen from TotalSegmentator MRI, IXI, AOMIC, SPIDER, and SKM-TEA.

Key Insights and Ideas

  • Don't learn where to refine while learning how to render: When the authors tried training the refinement switches jointly with the renderer, quality actually dropped by 0.44 dB below a coarse-only model. Decoupling them—training the renderer with random budgets first, then training the score head on frozen features—unlocked clean hierarchical detail.
  • Smart placement beats brute force: Refining just the top 10% of coarse Gaussians chosen by the learned score head matches the image quality of refining 50% at random, using $2.4\times$ fewer Gaussians.
Figure 3. Quality vs. rendered Gaussians (test). PSNR gain of RenderFM-Next over the parents-only model (95% CIs) with learned and with random selection at ρ ∈{10, 20, 30, 50}%.
  • Generalization beats per-scan overfitting: Compared to optimizing Gaussians per scan for 4–23 minutes (FactorSplat), feed-forward RenderFM-Next prepares a volume in ~1–2 seconds and scores 3.2 dB better on CT overall because it handles unseen clipping planes and out-of-distribution TF presets gracefully.

Key Results

Evaluated against a retrained RenderFM baseline (at a default 20% refinement budget on an A100 GPU at $1600^2$ resolution):

  • Image Quality: RenderFM-Next improves PSNR by +2.82 dB on CT (29.69 vs. 26.87 dB) and +2.38 dB on MR (28.63 vs. 26.25 dB). Coarse-to-fine refinement specifically shines on sliced anatomy, adding +0.51 dB (CT) and +1.17 dB (MR) directly on cut faces compared to using parents alone.
  • Interactive Speed: Renders views in 4.4–6.2 ms (162 FPS on CT, 229 FPS on MR). Moving a clipping plane takes just 12–17 ms, and TF edits take 35–51 ms (with the parents-only variant hitting 225–350 FPS and 15–21 ms TF edits).
  • Unified Efficiency: Combining CT and MR into one shared network halves total parameter count while costing only 0.11 dB (CT) and 0.29 dB (MR) compared to modality-specific specialist models.

Limitations and Future Work

  • Memory Overhead: Keeping up to eight 1.5-mm children ready in memory more than doubles peak VRAM usage compared to the coarse parents-only model (rising from 3.0 / 1.5 GB to 7.7 / 4.9 GB on CT / MR).
  • Preset Gaps: While dominant overall, RenderFM-Next still trails the retrained RenderFM baseline on 6 out of 15 specific clinical presets (such as CT lung/skin and MR neuro cortex).
  • Baked Lighting: Because Gaussians store appearance under fixed lighting, slicing away outer tissue doesn't dynamically cast new light onto newly exposed deeper organs. The authors highlight interactive relighting as the natural next frontier.

Summary updated

Abstract

Path-traced rendering shows CT and MR volumes with realistic lighting, but it restarts after every change of view, clipping plane or transfer function (TF), the map from voxel intensity to colour and opacity, which limits the frame rate. Feed-forward Gaussian splatting models such as RenderFM predict the Gaussians directly from the volume instead of fitting them to each scan, and are fast. RenderFM, however, handles only CT, runs its network again after every TF edit, has no clipping operator, and places its Gaussians on a uniform 3-mm grid that blurs organ boundaries and cut faces. We present RenderFM-Next, a feed-forward model that addresses these limits. One network handles both CT and MR. Its Gaussians are predicted once per volume: a new TF needs no pass of this network, and a clipping plane cuts them exactly, using operators from prior work. The model predicts coarse 3-mm Gaussians for the whole volume and refines them to 1.5 mm only where refinement improves the image. A small score head ranks the coarse Gaussians by how much refining them would reduce the rendering error; at render time the user chooses how many are refined, and those next to a clipping plane are always refined, which sharpens cut faces. We build a benchmark of about 2,000 CT and MR scans with path-traced references under clinical presets, TF edits and clipping. Our RenderFM-Next improves over RenderFM retrained on this benchmark by 2.8 dB on CT and 2.4 dB on MR and renders a 1600x1600 view in 4-6 ms. Refinement adds 0.30 / 0.69 dB over the same model trained without it (0.51 / 1.17 dB on cut faces), and refining a learned 10% of the coarse Gaussians matches a random 50% with 2.4x fewer Gaussians. Project page: https://gaozhongpai.github.io/renderfmnext/
BibTeX
@misc{gao2026feed,
  author = {Zhongpai Gao and Benjamin Planche and Meng Zheng and Anwesa Choudhuri and Chaoyi Zhou and Terrence Chen and Ziyan Wu},
  title = {{Feed-Forward Adaptive Gaussian Splatting for Interactive Medical Volume Rendering}},
  year = {2026},
  eprint = {2611.34478},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34478},
}
Figure