Fast integrated die-to-die transmitted, reflected and STAR<em>light-2</em> defect inspection on memory masks
Abstract
Single mode inspections, using die-to-die Transmitted (ddT) or die-to-die Reflected (ddR) modes, provides a high level of sensitivity to opaque and clear defects on reticles. Die-to-die (DD) inspections however, cannot inspect the scribes or frames which are potential locations for haze growth. Historically, STARLight-2<sup>TM</sup> (SL2) has been the only mode effectively utilized for contamination inspection in reticle scribes and frames. However, SL2 is designed for identifying contamination and not pattern defects on a mask. The solution presented here is Fast Integrated Inspection which includes ddT, ddR, and SL2, and allows the user to inspect a reticle for pattern and contamination defects over patterned areas and scribes simultaneously, and in unit time.
BibTeX
@inproceedings{lan2008fast,
author = {Andy Lan and Jenny Hsu and Swapnajit Chakravarty and Vincent Hsu and Ellison Chen and Eric Lu and John D. Miller},
title = {{Fast integrated die-to-die transmitted, reflected and STAR\<em\>light-2\</em\> defect inspection on memory masks}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2008},
doi = {10.1117/12.793060},
}Ask Althea to put this paper to the test.