NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Fast flux spectrum unfolding of PFTS of KAMINI: an investigation into the viability of radioisotope production

Subhrojit Bagchi, Manish Chand, Sujoy Sen, Bilal Khan, J. S. Brahmaji Rao, G. V. S. Ashok KumarJournal of Radioanalytical and Nuclear Chemistry 2024

Abstract

The fast component (0.7–18 MeV) of the neutron spectrum at the Pneumatic Fast Transfer System (PFTS) in the KAMINI reactor was determined by irradiating threshold activation foils. The acquired reaction rates are subsequently unfolded using SAND-II code. The KAMINI reactor was modelled in the MCNP-4B code for an estimate of neutron spectrum at the PFTS location, which was subsequently used as the initial apriori solution for the SAND-II code. The unfolded fast component spectrum at the PFTS was found to be similar to that of the fast benchmark GODIVA and JEZEBEL-23. Moreover, the investigation is substantiated by incorporating modified spectra to estimate the theoretical yield of radioisotopes $^{32}$P at PFTS using a Monte Carlo simulation against its experimental yield. The results agree with an accuracy of 6%, affirming the credibility of the derived spectrum. Theoretical yields of $^{89}$Sr, $^{64}$Cu, and $^{47}$Sc were also estimated at the same location.

Introduction

The KAMINI reactor, a unique $^{233}$U-fueled research facility in India, is primarily recognized for its thermal neutron applications, such as neutron radiography. However, its potential for producing high-purity, "carrier-free" medical radioisotopes remains largely untapped due to a lack of detailed characterization of its fast neutron component. These isotopes, essential for cancer diagnostics and pain management, require high-energy threshold reactions like (n, p) or (n, $\alpha$).

Characterizing the fast flux at the Pneumatic Fast Transfer System (PFTS)—the irradiation site closest to the reactor core—is critical for these applications. Since neutron spectra cannot be measured directly with a single sensor, researchers must employ "unfolding" techniques. This involves exposing various metal foils to radiation and using the resulting activity to mathematically reconstruct the original energy distribution.

Schematic layout of the KAMINI reactor showing the Pneumatic Fast Transfer System (PFTS) location.

Methodology

The study utilized a hybrid experimental-computational approach to characterize the neutron environment between 0.7 and 18 MeV. The process followed a structured workflow to reconcile physical measurements with theoretical models.

  1. Multi-foil Activation: Eight threshold reactions were monitored using foils of Titanium, Indium, Iron, Cobalt, Aluminum, and Yttrium. These materials only activate when struck by neutrons exceeding specific energy thresholds.
  2. MCNP-4B Modeling: A high-fidelity 3D Monte Carlo N-Particle (MCNP) model of KAMINI provided the initial "apriori" spectrum guess. Transport data was pulled from the ENDF/B-VIII.0 library.
  3. Spectrum Unfolding: The SAND-II code iteratively adjusted the MCNP guess until calculated reaction rates matched experimental measurements. Activation cross-sections were sourced from the JENDL-A96 library.
  4. Validation: The accuracy of the unfolded spectrum was verified by comparing the theoretical yield of Phosphorus-32 ($^{32}$P) against established experimental data.
Flowchart illustrating the experimental and computational steps to obtain the neutron energy spectrum at the PFTS location.

Results and Discussion

The unfolded fast neutron spectrum at the PFTS location was found to closely resemble the spectra of pure fast-burst reactors like GODIVA ($^{235}$U) and JEZEBEL-23 ($^{233}$U). This indicates that the KAMINI PFTS can effectively simulate high-energy environments despite being a light-water moderated reactor.

Validation through isotope production was highly successful. The theoretical MCNP model predicted $^{32}$P yields within 5.72% of experimental values, a high degree of accuracy for reactor physics. Based on this validated spectrum, the authors projected yields for several medically significant isotopes after a 6-hour irradiation at 20 kW:

  • Strontium-89 ($^{89}$Sr): 10.7 nCi/g (used for bone pain palliation).
  • Copper-64 ($^{64}$Cu): 0.16 mCi/g (used for PET imaging).
  • Scandium-47 ($^{47}$Sc): 18.81 $\mu$Ci/g (a promising "theranostic" isotope).

Conclusion

This research successfully characterized the fast neutron flux at the KAMINI PFTS, providing a validated roadmap for radioisotope production. While the study was limited to 6-hour irradiation windows, the results confirm the reactor's viability for producing high-purity medical isotopes. Future work will focus on optimizing target geometries and investigating longer irradiation durations to enhance commercial feasibility.

Summary updated

BibTeX
@article{bagchi2024fast,
  author = {Subhrojit Bagchi and Manish Chand and Sujoy Sen and Bilal Khan and J. S. Brahmaji Rao and G. V. S. Ashok Kumar},
  title = {{Fast flux spectrum unfolding of PFTS of KAMINI: an investigation into the viability of radioisotope production}},
  journal = {Journal of Radioanalytical and Nuclear Chemistry},
  year = {2024},
  doi = {10.1007/s10967-024-09581-9},
}
Figure