Abstract
This article focuses on the application of Affine Projection (AP) algorithms in active noise control (ANC) systems. ANC systems require real-time tracking and cancellation of noise signals, demanding high performance from digital signal processors. In multichannel configurations, computational overhead is a critical barrier to real-time execution. This paper introduces a simplified system structure based on an existing fast AP algorithm to reduce overhead and improve real-time performance. The proposed algorithm was validated using a DSP-based experimental platform.
Introduction
Active Noise Control (ANC) is a technique used to reduce unwanted noise by generating an "anti-noise" signal of equal amplitude but opposite phase. For these systems to be effective, they must operate with minimal latency. While the Normalized Least Mean Square (NLMS) algorithm is widely used due to its low computational cost, it suffers from slow convergence when dealing with highly correlated input signals, such as those found in many industrial environments.
The Affine Projection (AP) algorithm offers significantly faster convergence by utilizing multiple past input vectors. However, its implementation in multichannel systems—where multiple sensors and actuators are involved—is often computationally prohibitive. The primary challenge lies in the estimation of the "desired signal" required to calculate error vectors.
Structural Simplification: From FXAP to SFXAP
The standard Filtered-X Affine Projection (FXAP) algorithm involves a complex architecture to estimate the expected signal at the error sensors. This estimation process adds significant mathematical operations to every iteration, creating a bottleneck for real-time DSP implementation.
To address this, the authors propose the Simplified Fast Affine Projection (SFXAP) algorithm. The core innovation is the realization that historical signal data collected directly from error sensors can serve as elements in the error vector. By using these direct measurements, the system can bypass the "desired signal" estimation step entirely.
This structural change simplifies the block diagram and significantly reduces the number of required multiplications. To further optimize the system, the authors integrated three "fast" strategies: efficient error vector calculation, optimized inverse matrix calculation, and streamlined weight coefficient iteration.
Performance and Computational Complexity
The proposed Fast SFXAP algorithm was tested in a simulated 1:2:2 multichannel ANC system (one reference sensor, two speakers, and two error sensors). The results demonstrate that the simplified structure maintains nearly identical noise-reduction performance to the standard FXAP while drastically reducing the computational load.
In a configuration with a secondary modeling filter ($M$) of 128, an adaptive filter ($L$) of 64, and a projection depth ($N$) of 5, the computational savings are as follows:
- Standard FXAP: 11,218 multiplications per iteration.
- Existing Fast FXAP: 2,470 multiplications per iteration.
- Proposed Fast SFXAP: Only 1,378 multiplications per iteration.
This represents an 87.7% reduction in complexity compared to the standard FXAP and a 44.2% reduction over previous "fast" iterations. Qualitatively, the Fast SFXAP converged much faster than the standard FXLMS algorithm and achieved a lower steady-state error.
Conclusion
The Fast SFXAP algorithm successfully balances convergence speed and computational efficiency, making multichannel ANC feasible for standard DSP hardware. The study identifies a projection depth of $N=5$ as the optimal "sweet spot" for balancing performance and model stability. Future work will focus on testing the algorithm's robustness against non-stationary noise in complex real-world environments like automotive cabins.