FASCIA: Seeing Beneath the Surface with Queryable, Personalized Anatomy in Any Pose

R. James Cotton, Tim Unger, Lucinda WilliamsonarXiv 2026

TL;DR

FASCIA is a new framework that acts like a personalized, real-time X-ray for digital humans. By looking only at a person's external body shape and pose—even from a simple smartphone video—it can reconstruct a detailed 3D map of their internal anatomy, including 290 distinct bones, muscles, and organs.

What Problem Does This Paper Address?

We’ve become incredibly good at "markerless motion capture"—using AI to track how people move just by watching a video. But there’s a catch: these models are usually "skin deep." They see the surface, but they’re blind to what’s happening underneath.

If you’re a clinician or a sports scientist, knowing how a limb moves is only half the story. To calculate the actual forces on a joint or the work a specific muscle is doing, you need to know how mass is distributed inside the body. Traditionally, we’ve just scaled a "generic guy" template to fit a person's height and weight. But two people with the same external measurements can have vastly different internal compositions—one might have significantly more muscle mass or a different distribution of deep fat. FASCIA aims to bridge this gap by creating "musculoskeletal digital twins" that are personalized from the inside out.

Methods

The core of FASCIA (which stands for Functional Anatomical Structures and Composition via Implicit Atlas) is built on a few clever mathematical pillars:

  1. The Momentum Human Rig (MHR) Anchor: It uses a sophisticated skeletal model (MHR) as its foundation. This provides the external "shell" and the skeletal "pose" (joint angles and bone scales).
  2. Diffeomorphic Template Warping: Instead of trying to predict every internal voxel (3D pixel) from scratch—which often leads to "shattered" or disconnected bones—FASCIA starts with a high-resolution template of 290 structures. It then applies a smooth, invertible mathematical "warp" to morph that template into the specific shape of the individual. This ensures that a rib stays a rib and doesn't turn into a cloud of disconnected points.
  3. The Gaussian Prior: Because the outside doesn't perfectly predict the inside, the model uses a body-dependent Gaussian prior. This doesn't just give one "best guess"; it predicts the average internal structure and the statistical variability around it, allowing for uncertainty.
  4. Volumetric Posing: To make the internal tissues move realistically, FASCIA extends standard surface "skinning" into the 3D interior using harmonic fields (solving Laplace’s equation). This ensures that deep organs and muscles move coherently with the skeleton rather than just floating around.
Figure 1: FASCIA overview and architecture. Top (a–e): (a) Fit MHR (θ, β, s) to each training scan while retaining its partial labels A(y). (b) Canonical xc, body code z, and pose θ yield 290-structure probabilities P(k | xc, z) and posed location y = Φ(xc). (c) Partial-label supervision estimates template T, per-scan warps, and warp prior (µθ, σ, gθ). (d, e) Fitting MHR to any input (video, motion capture, or 3D scan) drives posed anatomical meshes, cross- sections, and BSIPs. Bottom (f–h): (f) Gaussian warp prior maps z to mean ˆα and draws α(d)

Datasets

The researchers trained FASCIA on a massive "multi-cohort" dataset of medical imagery:

  • Training Data: 584 scans in total (252 MRI and 332 CT).
  • MRI Data: The HIT whole-body MRI dataset, which provides coarse labels for five major tissue classes.
  • CT Data: Four different CT cohorts (VISCERAL, QUADRA, VSD, and Copenhagen) processed with automated tools to identify 290 fine-grained structures like individual muscles and specific bones.
  • Evaluation: The model was tested on 115 "held-out" scans (subjects the model had never seen before) to ensure it could generalize to new people.

Key Insights and Ideas

  • Warping > Pointwise Prediction: The biggest "aha" moment is that warping a template is far superior to predicting tissue types point-by-point. Pointwise methods tend to fragment thin, curved structures like the shoulder blade or ribs. Warping preserves the "topology"—the connected nature—of the human body.
  • Capturing Individual "Quirks": Previous models often regressed to the "cohort mean," essentially predicting an average body for everyone. FASCIA is much better at capturing individual differences, such as unique fat distributions, which are critical for accurate biomechanical modeling.
  • Coherent Interior Motion: By treating the interior of the body as a continuous field, the model avoids "implausible tissue folds" or stretching when the digital human moves into extreme poses.
Visualizing the six nested canonical layers of the FASCIA template, from skin to skeleton.

Key Results

  • High Accuracy: On CT scans, FASCIA achieved a mean volumetric Dice score (a measure of overlap) of 0.48 for named bones and 0.63 for muscles.
  • Better Fat Prediction: It significantly outperformed the previous state-of-the-art (HIT) in predicting whole-body adipose (fat) percentage, particularly in capturing the variance between individuals ($R^2 = 0.88$ for women compared to HIT's 0.38).
  • Precision Engineering: It recovered segment centers of mass within just 1.1 mm, which is vital for calculating joint torques accurately.
  • Blazing Fast: On a modern GPU (NVIDIA A100), personalizing the model takes about 34ms, and posing it for a new frame takes only 23ms. This makes it fast enough for near-real-time applications.

Limitations and Future Work

While FASCIA is a leap forward, the authors note a few areas for improvement:

  • Resolution Limits: At a 5mm grid spacing, very tiny structures like the bones in the hands or toes aren't perfectly resolved and can sometimes "merge" visually.
  • Static Training: The model is trained on people lying down (supine or prone) in scanners. It doesn't yet account for how organs shift when you stand up or how muscles bulge when they are actively contracting.
  • Missing Data: Some areas, like individual arm and forearm muscles, remain "unparcellated" because the automated tools used for training don't yet label them reliably.

Future work will likely focus on increasing the template resolution and incorporating "palpable bony landmarks" to help pin down the internal skeleton even more accurately from video.

Summary updated

Abstract

We present FASCIA (*Functional Anatomical Structures and Composition via Implicit Atlas*), a Momentum Human Rig (MHR)-anchored framework that predicts and poses a person's internal anatomy from their external body shape and skeletal proportions. FASCIA maps a single 290-structure population template onto each individual through a smooth, invertible warp. As people with the same shape can differ internally, a body-dependent Gaussian prior predicts both average warp coordinates and their inter-subject variability. The warp deforms a learned base template into bones, muscles, organs, and fat depots. Extending MHR skinning into the interior enables direct supervision of this model across four automatically labeled CT cohorts and one whole-body MRI cohort. On 82 held-out CT scans, FASCIA reaches a mean volumetric Dice (volume agreement) of 0.48 on named bones and 0.63 on muscles, keeps the majority of bones and muscles in one piece, and yields calibrated voxel probabilities. On 33 held-out whole-body MRI subjects, FASCIA's pointwise field improves tissue overlap over HIT across all compartments, predicts between-person differences in whole-body adipose percentage ($R^2 = 0.88$ vs. $0.38$ in women and $0.54$ vs. $-0.01$ in men), and recovers segment centers of mass within 1.1 mm. Because it needs only an MHR fit, FASCIA can be driven from images, video, or any system that outputs MHR. This opens the door to fitting individualized calibrated musculoskeletal digital twins to video motion data.
BibTeX
@misc{cotton2026fascia,
  author = {R. James Cotton and Tim Unger and Lucinda Williamson},
  title = {{FASCIA: Seeing Beneath the Surface with Queryable, Personalized Anatomy in Any Pose}},
  year = {2026},
  eprint = {2611.29970},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.29970},
}
Figure