EyeLS: Shadow-Guided Instrument Landing System for Target Approaching in Robotic Eye Surgery

Junjie Yang, Zhihao Zhao, Siyuan Shen, Daniel Zapp, Mathias Maier, Kai Huang, Nassir Navab, M. Ali NasseriIEEE RA-L 2024 · DOI

Abstract

In robotic ophthalmic surgery, navigating a surgical instrument to a precise intraocular target is a high-stakes task complicated by the limited depth perception of standard 2D microscopy. While intraoperative Optical Coherence Tomography (iOCT) provides high-resolution cross-sectional views, its narrow field of view makes the initial "target-approaching" phase difficult. This paper presents EyeLS, a novel navigation framework that utilizes the geometric relationship between surgical instruments and their shadows on the retinal surface to guide robotic needles. By treating the shadow as a visual landing aid, the system achieves sub-millimeter precision without requiring specialized 3D hardware.

Introduction

Precision in ophthalmic surgery is often measured in microns, yet the tools available to surgeons for global navigation are surprisingly limited. Standard surgical microscopes provide a top-down, 2D view of the eye, which lacks the depth information necessary to safely guide a needle toward the retina or a floating target in the vitreous humor. While intraoperative Optical Coherence Tomography (iOCT) offers the necessary depth resolution, it typically operates within a tiny 6x6 mm window. The challenge lies in the "initial target-approaching stage": moving the instrument from the entry trocar into this specific scanning window without overshooting and damaging delicate ocular tissues.

Existing solutions, such as 4D OCT or stereo-camera setups, often involve prohibitive costs, slow processing speeds, or significant modifications to the operating room workflow. EyeLS addresses this by leveraging the "free" depth information provided by shadows in standard 2D microscopy, creating a robust "Instrument Landing System" for robotic assistance.

The Shadow Theorem and Methodology

The core of the EyeLS framework is based on a geometric principle formalized as Theorem 1 (The Shadow Theorem). The theorem states that if a needle tip and a target overlap in a 2D image, and their respective shadows on the retina also overlap, then the needle tip and the target must occupy the same 3D position. This turns a complex 3D depth estimation problem into a 2D geometric alignment task.

The Three-Phase Approach

EyeLS guides the robotic needle through three distinct phases:

  1. Horizontal Alignment: The system performs an azimuthal rotation of the needle until it is aligned with the target in the 2D microscope view.
  2. Shadow Enabling: The needle is moved axially and rotated vertically until its shadow becomes visible on the retinal surface, providing the necessary depth cue.
  3. Shadow Alignment: In this final "landing" phase, the robot calculates an expected shadow trajectory. By adjusting the vertical angle and axial insertion simultaneously, the system ensures the needle's shadow intersects with the target's shadow, effectively "landing" the needle at the target coordinates.

To facilitate real-time operation, the system utilizes YOLOv8 for high-speed object detection and segmentation, tracking the needle, the light probe, the target, and their shadows in every frame.

Experimental Validation

The EyeLS framework was evaluated using both virtual and physical environments:

  • Unity-Based Simulator: A custom virtual human eye model (12mm radius) was used to test the motion logic against 1,926 random intraocular targets, including both retinal and floating targets.
  • Physical Model: A 3D-printed retinal model was used for qualitative validation. A segmentation model was trained on a small dataset of 158 images to demonstrate the system's feasibility with real-world camera feeds.

Results

The system demonstrated high precision in the simulated environment. For floating targets, EyeLS achieved an average depth (z-axis) error of just 0.0127 mm. For retinal targets, the average depth error was 0.3473 mm.

Out of nearly 2,000 trials, the system achieved a near-perfect success rate, failing only once due to a rare geometric alignment where the needle and shadow overlapped in a way that confused the tracking logic. Crucially, in all successful cases, the needle tip was positioned within 1 mm of the target in the x-y plane, placing it safely within the standard iOCT scanning range for the final stage of surgery.

Discussion and Key Insights

EyeLS introduces several advantages over previous shadow-based navigation methods. Most notably, it employs a side-approaching strategy. Unlike methods that move instruments vertically—often obscuring the target with the instrument itself—EyeLS uses axial-oriented insertion. This keeps the target visible to the surgeon and the tracking system throughout the procedure.

Furthermore, EyeLS provides a unified framework applicable to both retinal targets (e.g., subretinal injections) and floating targets (e.g., debris removal in the vitreous). The inclusion of a high-priority "safety check" ensures that the needle is automatically retracted if it approaches the retina too closely before reaching the target.

Limitations and Future Work

Despite its success in simulation, several hurdles remain for clinical translation. The system's reliance on image segmentation means that "sporadic shifting" of the needle mask can lead to robotic jitter. Additionally, the semi-transparent nature of the human retina may produce "fuzzier" shadows than those seen in 3D-printed models. Future research will focus on instrument-light coordination, enabling the robot to automatically move the light probe to maintain optimal shadow visibility and prevent the instrument from casting a shadow directly behind itself.

Summary updated

BibTeX
@article{yang2024eyels,
  author = {Junjie Yang and Zhihao Zhao and Siyuan Shen and Daniel Zapp and Mathias Maier and Kai Huang and Nassir Navab and M. Ali Nasseri},
  title = {{EyeLS: Shadow-Guided Instrument Landing System for Target Approaching in Robotic Eye Surgery}},
  journal = {IEEE Robotics Autom. Lett.},
  year = {2024},
  doi = {10.1109/lra.2024.3370000},
}

Loading related content...

Figure