TL;DR
EyeDiT is a generative model that creates realistic synthetic eye data grounded in actual 3D anatomy (cornea, iris) by training on multi-modal data, including Optical Coherence Tomography (OCT). It enables precise, independent control over gaze, pupil size, and subject identity, significantly narrowing the "sim-to-real" gap for eye-tracking systems in AR/VR applications.
What Problem Does This Paper Address?
Eye tracking (ET) is a cornerstone of AR/VR, enabling features like foveated rendering and gaze-based interaction. However, training robust ET models requires massive datasets with diverse gaze directions and pupil sizes, which are expensive and labor-intensive to collect from real humans.
While synthetic data offers a scalable alternative, existing generators are largely "image-centric." They produce 2D images that look realistic but lack a consistent underlying 3D structure. Crucially, they fail to model the complex 3D anatomy of the eye—specifically the transparent, refractive cornea. Because the cornea bends light, the "true" position of the iris and pupil is distorted in 2D images. Without modeling this 3D geometry, synthetic data often fails to generalize to real-world sensors, leading to a significant performance drop known as the sim-to-real gap.
Methods
The authors propose a two-stage pipeline called EyeDiT (Anatomy-Grounded Multi-Modal Eye Generation and Simulation).
- Multi-Modal Anatomy VAE (Stage 1): The model first learns a shared latent representation ($z_{fused}$) by encoding three distinct modalities: near-eye images, 3D OCT volumes (which act like high-resolution LiDAR for the eye), and labeled anatomy point clouds. This ensures the latent space is inherently "aware" of the eye's physical 3D structure.
- Eye Latent DiT (Stage 2): A Diffusion Transformer (DiT) is trained to generate these latent samples. It is conditioned on specific control parameters: the optical axis (gaze), pupil position and radius, and subject identity.
- Dual-Path Decoding: To render the results, the model uses two paths. One is a standard 2D image decoder, and the other is a 3D Gaussian Splatting (3DGS) decoder. The 3DGS path is particularly novel here; it allows the model to synthesize "novel views"—rendering the same eye from any arbitrary camera position without needing to retrain.
Datasets
The researchers introduced and utilized several key datasets:
- OCT-Cam-2V & OCT-Cam-4V: New datasets collected for this work, featuring 78 and 50 subjects respectively. They pair multi-view near-eye cameras with anterior-segment OCT scans to provide ground-truth 3D anatomy.
- LightDome: An existing high-quality eye image dataset used to test the model's ability to generalize to data without OCT.
- Nymeria: A public eye-tracking dataset recorded with Project Aria glasses, used as the "real-world" benchmark to evaluate the sim-to-real gap.
Key Insights and Ideas
- OCT as a Structural Prior: By using OCT during training, the model learns the "rules" of eye anatomy. Even when presented with only a single 2D image at test time, the model can infer the underlying 3D structure because it has seen how images and OCT volumes correlate across thousands of samples.
- One-Shot Simulation: A standout feature is the ability to take a single "context image" of a new subject and immediately simulate that subject's eye under different gaze and pupil conditions. This "one-shot" capability is much faster than previous methods that required per-subject optimization.
- Anatomy-Grounded Control: Because the model generates the 3D point cloud alongside the image, it provides perfect "readouts" of biometrics (like the exact center of the pupil in 3D space), which are impossible to get accurately from 2D-only models.
Key Results
- Superior Image Quality: In novel-view synthesis, EyeDiT achieved a PSNR of 24.9 dB from a single view, significantly outperforming the previous state-of-the-art of 21.8 dB.
- Closing the Sim-to-Real Gap: When a standard eye-tracking network was trained on EyeDiT's synthetic data and tested on real images, it achieved a gaze error of only 3.5°. For comparison, the same network trained on data from other popular generators (like UnityEyes) had an error of 8.4°.
- Boosting Real-World Performance: Combining real training data with EyeDiT-generated data further improved eye-tracking accuracy (reducing error from 2.6° to 2.3°), proving that the synthetic data is high-quality enough to augment real-world datasets effectively.
Limitations and Future Work
- Static Nature: The current model simulates the eye in a "quasi-static" manner. It does not yet capture temporal dynamics like the rapid movement of saccades or the mechanics of a blink.
- Eyeball Focus: The model focuses heavily on the eyeball itself. The authors note that modeling the periocular region (eyelids and skin) separately could further improve realism, as these areas move differently than the globe.
- OCT Requirement: While the model can run on images at test time, the training phase requires specialized OCT hardware, which is currently limited to clinical or high-end research settings.
Summary updated