Exploring Workplace Testing with Real-Time Polymerase Chain Reaction SARS-CoV-2 Testing

Lucas Fuentes, Nigam H. Shah, Sara Kelly, Glenn Harnett, Kevin A. SchulmanThe Journal of the American Board of Family Medicine 2022

TL;DR

This paper explores the feasibility and performance of a point-of-care (POC) real-time polymerase chain reaction (RT-PCR) test for SARS-CoV-2 in a high-volume workplace screening setting. The study demonstrates that POC RT-PCR testing can significantly reduce turnaround times compared to traditional lab-based RT-PCR, offering a more agile solution for maintaining workplace safety during a pandemic.

What Problem Does This Paper Address?

The COVID-19 pandemic highlighted the critical need for rapid and reliable diagnostic testing to enable safe workplace operations. Traditional laboratory-based RT-PCR tests, while considered the gold standard for accuracy, suffer from significant delays due to sample transport and batch processing. These delays can create a window of opportunity for virus transmission, especially in environments with close contact, such as professional sports. The paper addresses the challenge of bridging this gap by investigating whether a point-of-care (POC) RT-PCR test could provide the accuracy of RT-PCR with the speed needed for effective workplace screening, thereby enhancing public health and safety.

Methods

The study employed a comparative approach, evaluating a novel POC RT-PCR assay against a standard laboratory-based RT-PCR test. The research was conducted as part of the National Basketball Association (NBA) summer program in Orlando, Florida, during the 2020 NBA Summer League.

  • Sample Collection: Dual nostril midturbinate specimens were collected from NBA support personnel. One sample was designated for the laboratory RT-PCR test, and the other for the POC RT-PCR test.
  • POC RT-PCR Testing: The study utilized an investigational, single-use, disposable, fully-integrated, rapid, automated RT-PCR device (Visby Medical). This device was used under specific protocols and has since received FDA emergency use authorization.
  • Laboratory RT-PCR Testing: This served as the "gold standard" for comparison, using the Roche cobas assay system.
  • Validation Study: To further assess the performance of the POC device, particularly for positive or indeterminate results, a validation protocol was implemented. This involved retesting samples with new POC devices to adjudicate initial findings.
  • Data Management: Clinical trial data were securely stored in an IQVIA database, with participant identifiers anonymized.

Datasets

The study utilized samples collected from 978 NBA support personnel participating in the NBA Universal Screening program during the 2020 NBA Summer League. A total of 852 samples were considered valid for analysis across both the POC and laboratory RT-PCR tests. No new benchmarks were introduced; the study focused on comparing the performance of a novel POC test against an established laboratory standard.

Key Insights and Ideas

  • POC RT-PCR is a Viable Option for Rapid Screening: The study demonstrates that RT-PCR technology can be successfully deployed at the point of care, offering a significant speed advantage over traditional lab-based testing.
  • Dramatic Reduction in Turnaround Time: The most striking insight is the substantial decrease in the time it takes to receive test results, which is crucial for timely intervention and preventing further spread.
  • Balancing Speed and Accuracy: While POC tests often face trade-offs between speed and sensitivity/specificity, this study shows that RT-PCR-based POC testing can maintain high diagnostic performance.
  • The Importance of Context for Test Performance: The paper highlights how population prevalence significantly impacts the predictive values of diagnostic tests, particularly for false positives.
  • Validation is Key for Investigational Devices: The validation study underscored the importance of confirmatory testing for investigational devices, especially in identifying and mitigating potential false positives, though it can impact overall turnaround time.

Key Results

  • Turnaround Time: The POC RT-PCR test reduced the average turnaround time to 110 minutes (SD 37 minutes), a stark contrast to the 754 minutes (SD 207 minutes) required for laboratory-based RT-PCR testing. This represents an almost 7-fold increase in diagnostic speed.
  • Sensitivity and Specificity (Initial Analysis): The POC test demonstrated a sensitivity of 100% and a specificity of 98.7% when compared to the laboratory RT-PCR.
  • Validation Study Impact: In the validation study, the number of positive results decreased from 12 to 2, suggesting a reduction in false positives. However, this process also led to a reported sensitivity of 0% and a specificity of 99.8% for the POC test in this specific validation scenario, indicating that some true positives might have been misclassified as false negatives during the retesting.
  • Sample Validity: 94% of laboratory RT-PCR samples and 96% of single-test POC samples were considered valid for analysis.

Limitations and Future Work

  • Single Population and Setting: The study was conducted on one specific population (NBA support personnel) within a defined setting (NBA summer program). The performance of the POC test may vary in different clinical settings or with different populations.
  • Staffing Requirements: While the POC test is rapid, it still requires trained personnel for administration, specimen preparation, and data entry, which can impact staffing needs for large-scale screening.
  • Data Reporting: The POC device used had analog results reporting, necessitating manual data entry into a database, which introduces a potential for reporting errors. The authors suggest that conversion to a digital reporting format could address this.
  • Contamination Risk: The authors acknowledge a potential for contamination in the field setting, which could lead to false-positive results.
  • Photographic Interpretation Errors: In a quality review, some test results read as positive on-site were later read as negative from photographs, highlighting the need for better documentation and training, especially for investigational devices.
  • Self-Administered Tests: The study involved direct observation of sample collection. The performance of self-administered tests in a workplace environment might not achieve the same high level of accuracy.

Future work could focus on optimizing digital reporting for POC devices, further investigating the impact of different prevalence rates on test performance, and exploring the cost-effectiveness of POC RT-PCR testing in various workplace scenarios.

Summary updated

Abstract

POC testing for SARS-CoV-2 with RT-PCR technology is possible at reduced time compared with send-out PCR testing.
BibTeX
@article{fuentes2022exploring,
  author = {Lucas Fuentes and Nigam H. Shah and Sara Kelly and Glenn Harnett and Kevin A. Schulman},
  title = {{Exploring Workplace Testing with Real-Time Polymerase Chain Reaction SARS-CoV-2 Testing}},
  journal = {The Journal of the American Board of Family Medicine},
  year = {2022},
  doi = {10.3122/jabfm.2022.01.210284},
}
Figure