Exploring Image Quality Assessment from a New Perspective: Pupil Size

Yixuan Gao, Xiongkuo Min, Guangtao ZhaiarXiv 2025 · DOI

Introduction

Image Quality Assessment (IQA) is a fundamental component of digital media processing, traditionally categorized into subjective and objective methods. Subjective scoring, while considered the "ground truth," is often plagued by human factors such as fatigue, inconsistency, and misunderstanding of rating scales. Conversely, objective models aim to predict these scores algorithmically but frequently fail to capture the intricate nuances of the Human Visual System (HVS).

This research explores a physiological "third way": using pupil size as a direct window into the brain's authentic reaction to image quality. Beyond simple light reflexes, pupil diameter is a known indicator of cognitive load and mental effort, making it a promising candidate for bypassing manual scoring biases.

Methodology

The study employed a controlled experimental design involving 17 subjects and 100 distorted images from the standard LIVE database. The images covered five distortion types: JPEG2000, JPEG, White Noise, Gaussian Blur, and Fast-fading Rayleigh.

Participants performed two distinct tasks while their pupil diameters were recorded using a Tobii Pro X3-120 eye tracker at 120Hz:

  1. Free Observation: Subjects viewed images naturally, simulating casual browsing.
  2. IQA Task: Subjects actively evaluated and scored images on a five-point scale (Bad to Excellent).
Experimental paradigms for Task 1 (Free observation) and Task 2 (Image Quality Assessment).

The analysis focused on isolating the "task-evoked" pupil response by separating the data into two phases: the Constriction Phase (initial reaction to image luminance) and the Recovery Phase (dilation as the brain processes content and quality).

Key Insights and Results

Task-Evoked Oscillation and Attention

A primary finding was that the IQA task induces significantly more pupil oscillation compared to free viewing. This suggests a specific visual attention mechanism where the pupil dilates to gather global information and constricts to scrutinize local artifacts or blur. Statistical analysis (ANOVA) confirmed that pupil size changes during active assessment were significantly different from natural observation ($F = 344.37, p < 0.01$).

Pupil Recovery as a Quality Metric

While the initial constriction is largely driven by light, the recovery phase proved to be highly sensitive to perceived quality. The researchers identified a "Pupil Recovery Slope" ($K$) and found a consistent trend: higher-quality images result in a slower, more gradual recovery, whereas low-quality images trigger a rapid "bounce back" after the initial constriction.

Average pupil size changes over time for Task 1 and Task 2, highlighting the constriction and recovery phases.

Observation Time

The data also revealed that subjects spend less time looking at poor-quality images. Observation time for "Bad" images was the shortest across both tasks, indicating that the brain identifies high levels of distortion rapidly and loses interest. On average, people spent ~3.45s "appreciating" images during free viewing compared to ~2.74s "judging" them during the IQA task.

Conclusion and Future Work

This study provides a proof-of-concept for using physiological signals to assess image quality. By demonstrating that pupil recovery speed correlates with perceived distortion, the researchers have opened a path toward more authentic, HVS-aligned IQA models.

Future research will aim to validate these findings with larger, more diverse populations and "authentic" distortions found in modern smartphone photography. The ultimate goal is to integrate these physiological insights into objective algorithms that can simulate human reactions without requiring expensive eye-tracking hardware for every assessment.

Summary updated

Abstract

This paper explores how the image quality assessment (IQA) task affects the cognitive processes of people from the perspective of pupil size and studies the relationship between pupil size and image quality. Specifically, we first invited subjects to participate in a subjective experiment, which includes two tasks: free observation and IQA. In the free observation task, subjects did not need to perform any action, and they only needed to observe images as they usually do with an album. In the IQA task, subjects were required to score images according to their overall impression of image quality. Then, by analyzing the difference in pupil size between the two tasks, we find that people may activate the visual attention mechanism when evaluating image quality. Meanwhile, we also find that the change in pupil size is closely related to image quality in the IQA task. For future research on IQA, this research can not only provide a theoretical basis for the objective IQA method and promote the development of more effective objective IQA methods, but also provide a new subjective IQA method for collecting the authentic subjective impression of image quality.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
Pupil recovery ranges ΔE for different image quality levelsPupil-size analysispupil recovery range ΔE, Bad quality, Task 11.053 mmVisual Observation · task=free observation · phase=recovery · quality=bad
Source quote
L222: Task 1 │ 1.053 │ 0.621 │ 0.619 │ 0.614 │ 0.599
Pupil recovery ranges ΔE for different image quality levelsPupil-size analysispupil recovery range ΔE, Bad quality, Task 20.294 mmImage Quality Assessment · task=IQA · phase=recovery · quality=bad
Source quote
L223: Task 2 │ 0.294 │ 0.494 │ 0.574 │ 0.369 │ 0.144
Pupil recovery ranges ΔE for different image quality levelsPupil-size analysispupil recovery range ΔE, Excellent quality, Task 10.599 mmVisual Observation · task=free observation · phase=recovery · quality=excellent
Source quote
L222: Task 1 │ 1.053 │ 0.621 │ 0.619 │ 0.614 │ 0.599
Pupil recovery ranges ΔE for different image quality levelsPupil-size analysispupil recovery range ΔE, Excellent quality, Task 20.144 mmImage Quality Assessment · task=IQA · phase=recovery · quality=excellent
Source quote
L223: Task 2 │ 0.294 │ 0.494 │ 0.574 │ 0.369 │ 0.144
BibTeX
@misc{gao2025exploring,
  author = {Yixuan Gao and Xiongkuo Min and Guangtao Zhai},
  title = {{Exploring Image Quality Assessment from a New Perspective: Pupil Size}},
  year = {2025},
  eprint = {2505.13841},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2505.13841},
}
Figure