Exploring cosmic origins with CORE: The instrument

P. de Bernardis, P. A. R. Ade, J. J. A. Baselmans, E. S. Battistelli, A. Benoı̂t, M. Bersanelli, A. Bideaud, M. Calvo Gomez, F. J. Casas, M. G. Castellano, A. Catalano, I. Charles, I. Colantoni, F. Columbro, A. Coppolecchia, M. Crook, G. D’Alessandro, M. De Petris, G. de Zotti, S. Doyle, C. Franceschet, A. Gómez, J. Goupy, S. Hanany, M. Hills, L. Lamagna, J. F. Macías–Pérez, B. Maffei, S. Martín, E. Martínez-González, S. Masi, D. McCarthy, A. Mennella, A. Monfardini, F. Noviello, A. Paiella, F. Piacentini, M. Piat, G. Pisano, G. Signorelli, C. Y. Tan, A. Tartari, N. Trappe, S. Triqueneaux, C. Tucker, G. Vermeulen, K. Young, M. Zannoni, A. Achúcarro, R. Allison, E. Artal, M. Ashdown, M. Ballardini, A. J. Banday, R. Banerji, J. G. Bartlett, N. Bartolo, S. Basak, A. Bonaldi, Matteo Bonato, J. Borrill, F. R. Bouchet, F. Boulanger, T. Brinckmann, M. Bucher, C. Burigana, A. Buzzelli, Zhen-Yi Cai, C. S. Carvalho, A. Challinor, Jens Chluba, Sébastien Clesse, G. de Gasperis, E. Di Valentino, J. M. Diego, J. Errard, S. Feeney, R. Fernández-Cobos, F. Finelli⋆, F. Forastieri, S. Galli, R. T. Génova-Santos, M. Gerbino, J. González-Nuevo, S. Hagstotz, J. Greenslade, Will Handley, C. Hernández-Monteagudo, Carlos Hervías-Caimapo, E. Hivon, K. Kiiveri, T. Kisner, T. Kitching, M. Kunz, H. Kurki‐Suonio, A. Lasenby, M. Lattanzi, J. Lesgourgues, Zhi LiJournal of Cosmology and Astroparticle Physics 2018 · DOI

TL;DR

The CORE instrument is a proposed space-based polarimeter designed to precisely measure the polarization of the Cosmic Microwave Background (CMB). This ambitious mission aims to unlock fundamental secrets about the early universe, including testing cosmic inflation and probing dark matter distribution, by achieving unprecedented sensitivity and sky coverage.

What Problem Does This Paper Address?

Measuring the polarization of the CMB is crucial for understanding the very early universe, particularly for testing the theory of cosmic inflation and searching for primordial gravitational waves (B-modes). However, these signals are incredibly faint and easily obscured by polarized foreground emissions from our own galaxy. Ground-based experiments face limitations due to atmospheric interference and incomplete sky coverage. Therefore, a highly sensitive, full-sky space-based mission is required to achieve the necessary precision. CORE aims to be that mission, pushing the boundaries of CMB polarization measurements to unprecedented levels.

Methods

CORE employs a sophisticated instrument design optimized for sensitivity and systematic error mitigation. Key features include:

  • 1.2m Aperture Telescope: A crossed-Dragone telescope design is chosen for its ability to provide a large, flat, and telecentric focal plane, ideal for accommodating a dense array of detectors. This design offers advantages in terms of optical performance and polarization characteristics compared to Gregorian designs.
  • Microwave Kinetic Inductance Detectors (MKIDs): These highly sensitive detectors are selected for their advanced technology, intrinsic frequency domain multiplexing, and fast response time. They are designed to operate across a wide frequency range (60-600 GHz) in 19 distinct bands.
  • Cryogenic System: A multi-stage cryogenic system is essential to cool the detectors to ~100 mK and the telescope optics to 40-100 K, minimizing thermal noise. This system leverages heritage from previous space missions like Planck.
  • Pointing Strategy: Instead of a mechanical polarization modulator, CORE relies on a sophisticated pointing strategy that rotates the spacecraft to scan sky pixels from multiple directions. This simplifies the instrument and reduces potential systematic errors.
  • Component Selection: The instrument utilizes space-qualified components with high Technology Readiness Levels (TRLs), minimizing development risk.

Datasets

Not discussed in the paper. The paper focuses on the instrument design and its capabilities, not on data analysis from existing datasets.

Key Insights and Ideas

  • The Power of Space-Based CMB Polarization: The paper strongly advocates for space-based missions like CORE, highlighting their unique ability to overcome the limitations of ground-based observations for precise CMB polarization measurements, especially for large angular scales and high frequencies.
  • MKIDs as the Detector of Choice: The adoption of MKIDs signifies a leap in detector technology, offering a path to the required sensitivity and multiplexing capabilities for a mission with thousands of detectors.
  • Simplicity Through Pointing Strategy: The decision to forgo a mechanical polarization modulator in favor of a sophisticated pointing strategy is a key design choice that enhances reliability and reduces complexity.
  • A Multi-Disciplinary Science Case: CORE's scientific goals extend beyond inflation, encompassing dark matter distribution, galaxy cluster studies, and galactic magnetic field research, demonstrating the broad impact of precise CMB polarization measurements.

Key Results

The paper details the proposed baseline configuration of the CORE instrument, including:

  • Telescope: A 1.2m aperture crossed-Dragone telescope.
  • Detectors: An array of 2100 single-band, single-polarization MKID detectors.
  • Frequency Coverage: 19 frequency bands spanning 60 GHz to 600 GHz.
  • Sensitivity: A projected CMB polarization survey sensitivity of 1.7 µK·arcmin for the full array.
  • Downscoping Option: A reduced version (MiniCORE) with an 80cm telescope and 900 detectors is also described, offering a CMB polarization sensitivity of 3.2 µK·arcmin.

Limitations and Future Work

The authors acknowledge several areas for future work and potential limitations:

  • Optical Performance Optimization: While the crossed-Dragone design is promising, further optimization of the optical system is ongoing.
  • Polarization Modulator Decision: While the pointing strategy is the baseline, end-to-end simulations will be performed to confirm the decision not to use a polarization modulator.
  • Low Frequency Detector Development: The low-frequency bands (60-115 GHz) require further development, particularly in materials and on-chip polarization sensitivity.
  • Calibration Accuracy: Achieving the required calibration accuracy for systematic error mitigation is a significant challenge, and detailed plans for ground and in-flight calibration are outlined.
  • Downscoping Trade-offs: The MiniCORE option involves trade-offs in angular resolution and sensitivity for certain science goals, but maintains core CMB polarization capabilities.

Summary updated

Abstract

PdB acknowledges support from University of Rome La Sapienza (project “Cosmologia di Precisione 2015”) and from the Italian Space Agency (Agreement 2016-019-H.0 “Kinetic Inductance Detectors for Space”). CJM is supported by an FCT Research Professorship, contract reference IF/00064/2012, funded by FCT/MCTES (Portugal) and POPH/FSE (EC). C.H.-M. acknowledges the financial support of the Spanish Ministry of Economy and Competitiveness via I+D project AYA-2015-66211-C2-2-P. GDZ acknowledges the financial support of ASI/INAF agreement n. 2014-024-R.1. J.G.N. acknowledges financial support from the Spanish MINECO for a “Ramon y Cajal” fellowship (RYC-2013-13256) and the I+D 2015 project AYA2015-65887-P (MINECO/FEDER). F.J.C., E.M.-G. and P.V. acknowledge support from the Spanish Ministerio de Econom´ıa y Competitividad project ESP2015-70646- C2-1-R co-financed with EU FEDER funds.
BibTeX
@article{bernardis2018exploring,
  author = {P. de Bernardis and P. A. R. Ade and J. J. A. Baselmans and E. S. Battistelli and A. Benoı̂t and M. Bersanelli and A. Bideaud and M. Calvo Gomez and F. J. Casas and M. G. Castellano and A. Catalano and I. Charles and I. Colantoni and F. Columbro and A. Coppolecchia and M. Crook and G. D’Alessandro and M. De Petris and G. de Zotti and S. Doyle and C. Franceschet and A. Gómez and J. Goupy and S. Hanany and M. Hills and L. Lamagna and J. F. Macías–Pérez and B. Maffei and S. Martín and E. Martínez-González and S. Masi and D. McCarthy and A. Mennella and A. Monfardini and F. Noviello and A. Paiella and F. Piacentini and M. Piat and G. Pisano and G. Signorelli and C. Y. Tan and A. Tartari and N. Trappe and S. Triqueneaux and C. Tucker and G. Vermeulen and K. Young and M. Zannoni and A. Achúcarro and R. Allison and E. Artal and M. Ashdown and M. Ballardini and A. J. Banday and R. Banerji and J. G. Bartlett and N. Bartolo and S. Basak and A. Bonaldi and Matteo Bonato and J. Borrill and F. R. Bouchet and F. Boulanger and T. Brinckmann and M. Bucher and C. Burigana and A. Buzzelli and Zhen-Yi Cai and C. S. Carvalho and A. Challinor and Jens Chluba and Sébastien Clesse and G. de Gasperis and G. de Zotti and E. Di Valentino and J. M. Diego and J. Errard and S. Feeney and R. Fernández-Cobos and F. Finelli⋆ and F. Forastieri and S. Galli and R. T. Génova-Santos and M. Gerbino and J. González-Nuevo and S. Hagstotz and J. Greenslade and Will Handley and C. Hernández-Monteagudo and Carlos Hervías-Caimapo and E. Hivon and K. Kiiveri and T. Kisner and T. Kitching and M. Kunz and H. Kurki‐Suonio and A. Lasenby and M. Lattanzi and J. Lesgourgues and Zhi Li},
  title = {{Exploring cosmic origins with CORE: The instrument}},
  journal = {Journal of Cosmology and Astroparticle Physics},
  year = {2018},
  doi = {10.1088/1475-7516/2018/04/015},
}
Figure