Experimental Verification of Deep Field Weakening Operation of a 50-kW IPM Machine by Using Single Current Regulator

Yuan Zhang, Longya Xu, M.k. Guven, Song Chi, Mahesh S. IllindalaIEEE Transactions on Industry Applications 2010 · DOI

Abstract

This paper analyzes critical control issues associated with the deep field weakening operation of interior permanent magnet (IPM) synchronous machines. The singlecurrent-regulator control algorithm is reviewed, which controls the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">d</i> -axis current actively and gives a fixed <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i> -axis voltage command. To achieve better operational efficiency and performance, improvements are made to choose an optimal <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">q</i> -axis voltage for variable-speed and variable-load conditions. The control algorithm is implemented on a 50-kW IPM machine. Test results, including 7:1 constant power speed ratio operation, are presented to verify the theoretical analysis.
BibTeX
@article{zhang2010experimental,
  author = {Yuan Zhang and Longya Xu and M.K. Guven and Song Chi and Mahesh S. Illindala},
  title = {{Experimental Verification of Deep Field Weakening Operation of a 50-kW IPM Machine by Using Single Current Regulator}},
  journal = {IEEE Transactions on Industry Applications},
  year = {2010},
  doi = {10.1109/tia.2010.2091478},
}

Loading related content...

Figure