Experimental Study on the Spillway Shape Optimization in Xiaohe Hydropower Station

Chuan LeiChina 2006

Abstract

The test discharge capacity is bigger than the design discharge capacity in Xiaohe hydropower station.The optimization of the integer layout can meet the requirement and decrease the engineering quantity.Through the model tests,the more ideal results are obtained,and the problems of outlet dissipater and the water hat behind piers.The following conclusions are drawn that ① the water hat is almost eliminated,impact wave height is consumedly decreased,and the flow of spillway is stable through decreasing the middle piers from originally 4.0 m to 3.0 m and ending it with streamline tail piers;② Through comparing with slit bucket deflecting bucket,deflecting bucket can better connect the water flows between spillway and the downstream course of river,dissipate the energy of water flow,and improve the states of the downstream water flow at the same time.
BibTeX
@inproceedings{lei2006experimental,
  author = {Chuan Lei},
  title = {{Experimental Study on the Spillway Shape Optimization in Xiaohe Hydropower Station}},
  booktitle = {China},
  year = {2006},
}