TL;DR
This paper investigates a novel "short-lapped-rebar splice" connection for precast concrete structures, featuring pre-set holes and spiral hoops. Experimental results demonstrate that this new splice offers significantly improved ultimate bond strength (up to 1.4 times conventional splices) and a more symmetrical stress distribution, leading to rebar fracture rather than pull-out failure in optimized configurations. A new semi-empirical model accurately predicts this enhanced performance.
What Problem Does This Paper Address?
Precast concrete construction offers advantages like faster construction and reduced labor. A critical element in these structures is the connection between reinforcing bars (rebars), often achieved through lapped splices. Traditional lapped splices can lead to concrete cracking near the connection zone, potentially compromising structural integrity. Existing solutions like corrugated metal ducts and spiral hoops have been explored, but some methods (e.g., those involving rotated steel rods) can be complex to fix and may still induce cracking. This research addresses the need for a more robust, simpler, and effective rebar connection method for precast concrete shear walls that minimizes cracking and maximizes bond strength.
Methods
The study employed an experimental approach involving the fabrication and testing of 30 specimens of the proposed "short-lapped-rebar splice." These specimens were designed to vary rebar diameter (12, 16, and 20 mm) and lapped length (0.05, 0.1, and 0.15 times the suggested length from GB 50010-2010). The core of the splice involves a corrugated metal duct, spiral hoops welded to the embedded rebar for stability, and pre-set holes. Tension testing was conducted using a steel frame loading rack. Strain gauges were strategically placed along the anchored rebar to measure strain distribution, and displacement meters captured slip. Based on the experimental data, a semi-empirical model was developed to predict the ultimate bond strength.
Datasets
Not discussed in the paper. The study relies on experimental data generated from the 30 fabricated specimens.
Key Insights and Ideas
- Optimized Lapped Length is Crucial: The study highlights a critical transition in failure modes. Shorter lapped lengths (0.1 and 0.05 times the suggested length) resulted in rebar pull-out failure, indicating insufficient bond. However, a lapped length of 0.15 times the suggested length led to rebar fracture, signifying that the bond strength exceeded the rebar's tensile capacity – a desirable outcome for robust connections.
- Spiral Hoops Enhance Confinement: The inclusion of spiral hoops, welded to the embedded rebar, plays a significant role in confining the grout mortar. This confinement effectively limits crack development, a common issue in conventional splices, and contributes to the increased ultimate bond strength.
- Symmetrical Stress Distribution: Unlike conventional splices where stress is concentrated at the anchorage end, the short-lapped-rebar splices exhibit a more symmetrical distribution of stress along the longitudinal direction. This even distribution is likely a key factor in their improved performance and reduced cracking.
- Significant Bond Strength Improvement: The new splice design achieved an ultimate bond strength of up to 35 MPa, which is approximately 1.4 times that of conventional specimens. This substantial increase is a direct result of the combined effects of the spiral hoops, grout material, and the optimized geometry.
- A Predictive Model is Born: The development of a semi-empirical model that accurately predicts the ultimate bond strength is a significant contribution. This model, with an average error of only 4.49%, can aid engineers in designing these new splices with confidence.
Key Results
- Failure Modes: Specimens with 0.15 times the suggested lapped length failed by rebar fracture, while those with 0.1 and 0.05 times the suggested length failed by rebar pull-out.
- Ultimate Bond Strength: The maximum bond stress reached 35 MPa, approximately 1.4 times that of conventional specimens.
- Stress Distribution: The stress in the anchored rebar was distributed symmetrically along the longitudinal direction.
- Model Accuracy: The proposed semi-empirical model showed good agreement with tested values, with an average error of 4.49%.
Limitations and Future Work
The authors acknowledge that the cyclic behavior of the short-lapped-rebar splices and their overall structural reliability were not investigated in this study. They suggest that further research is needed to determine the optimal lapped length for design purposes. Future work could also explore the performance of these splices under seismic loading and investigate the long-term durability and behavior under various environmental conditions.
Summary updated