Experimental investigation of magnetic abrasive finishing of 316L stainless steel by permanent magnet device
Abstract
Basedon magnetic abrasive finishing, the 316L stainless steel was finished using permanent magnet pole device absorbent new spherical abrasive produced by gas atomization.The effects of the spindle revolution, working gap, magnetic abrasive size and abrasivesize on surface roughness and material removal quantity and its variation ruleswere studied when the time and the magnetic flux density was a fix value. And useorthogonal design to summarize the optimized machining parameters: S(spindle revolution)= 1 000 r/min, δ(working gap)=1.5 mm, magnetic abrasive size is 150~124 μm, which changethe average initial roughness of the work piece surfacefrom 0.275 μm to 0.038 μm(The original surface roughness of work piece is 2.76 μm) .
BibTeX
@inproceedings{zhang2013experimental,
author = {Pingping Zhang},
title = {{Experimental investigation of magnetic abrasive finishing of 316L stainless steel by permanent magnet device}},
booktitle = {Manufacturing},
year = {2013},