Evidential Deep Learning with conditional entropy for glaucoma detection

Hai Siong Tan, Kuancheng WangarXiv 2026 · arXiv

TL;DR

This paper introduces a novel conditional entropy function for Evidential Deep Learning (EDL) to improve uncertainty quantification in glaucoma detection. By regularizing models with this information-theoretic approach, the authors achieved significantly better-calibrated predictions and more clinically consistent interpretability compared to standard methods like Deep Ensembles and MC Dropout.

What Problem Does This Paper Address?

Deep learning models are increasingly effective at medical tasks like detecting glaucoma from retinal fundus images. However, most models are "black boxes" that provide a classification without a reliable measure of confidence. In safety-critical medical screening, an overconfident but wrong prediction can lead to missed diagnoses (false negatives).

While Evidential Deep Learning (EDL) was designed to quantify uncertainty by predicting the parameters of a probability distribution (rather than just a single class), its original formulation relied on Dempster-Shafer theory. The authors argue that this lacks a solid information-theoretic foundation. They sought to create a more robust uncertainty metric that aligns with Bayesian principles and provides clinicians with a clear signal of when to trust—or double-check—a model's output.

Methods

The authors propose a "coarse-grained" conditional entropy function ($S_c$) as the basis for uncertainty.

  1. The Math: In a binary classification task (glaucoma vs. healthy), EDL assumes the class probability follows a Beta distribution (defined by parameters $\alpha$ and $\beta$). The authors derived $S_c$ by marginalizing the standard Shannon entropy over this Beta prior.
  2. The Regularizer: They integrated this entropy function into the model's training via a novel regularizer ($L_c$). This term penalizes the model for being certain when it is wrong, effectively "pushing" the model toward higher entropy (higher uncertainty) for erroneous classifications.
  3. The Architecture: They used a MobileNetV3-Small backbone with a custom multi-layer perceptron (MLP) head to output the $\alpha$ and $\beta$ parameters.
  4. Interpretability: To understand why the model was uncertain, they used Grad-CAM to generate heatmaps and calculated a "focus index" to measure how concentrated the model's attention was on specific spatial regions.
Figure 1: Contour plot of the conditional entropy function $S_c$. Darker regions represent lower uncertainty. The function is maximized when $\alpha = \beta$ (maximum ambiguity) and minimized as the parameters grow toward certain outcomes.

Datasets

The study utilized several key datasets to validate performance and out-of-distribution (OOD) robustness:

  • EyePACS-AIROGS-light-V2: A large, standardized full-fundus dataset.
  • RIM-ONE-DL: A dataset of fundus images cropped specifically around the optic nerve head.
  • CRFO and ACRIMA: Used specifically to test OOD detection, as these datasets contain systematic distributional shifts (like different luminance) compared to the training sets.

Key Insights and Ideas

  • Information Theory over Heuristics: By replacing the original EDL "Dempster uncertainty" with conditional entropy, the authors grounded the model in conventional statistical principles. This led to superior performance without needing complex Bayesian approximations.
  • Uncertainty as a Discriminator: The proposed EDL model showed a much clearer separation in uncertainty distributions between correct and incorrect predictions. This means that when the model is wrong, it is much more likely to "know" it is unsure.
  • Physiological Consistency: The "Focus Index" revealed a fascinating trend: for the EDL model, false negatives (missing a glaucoma case) were often associated with the model's attention being "misplaced"—focused on areas away from the optic disc. Since the optic disc is the clinically vital area for glaucoma assessment, this behavior makes the model's errors more interpretable and potentially easier for a human to flag.

Key Results

  • Lower Calibration Error: The proposed model achieved the lowest Expected Calibration Error (ECE) across both major datasets. For example, on the EyePACS dataset, the conditional EDL achieved an ECE of 0.019, significantly outperforming Deep Ensembles (0.030) and MC Dropout (0.044).
  • Superior OOD Detection: The model achieved the highest AUROC for identifying out-of-distribution images (0.87 on EyePACS), making it safer for deployment in diverse clinical settings where image quality or equipment might vary.
  • Accuracy: While the primary goal was uncertainty, the model also maintained or slightly improved top-level accuracy (~92%) and AUC (~0.96-0.98) compared to baseline models.

Limitations and Future Work

The authors acknowledge a few areas for further exploration:

  • Backbone Diversity: The study focused on MobileNetV3. Testing the approach on Vision Transformers (ViTs) would help determine if these benefits are architecture-independent.
  • Uncertainty Types: Future work could investigate whether this conditional entropy represents aleatoric uncertainty (inherent noise in the data) or epistemic uncertainty (lack of model knowledge).
  • Clinical Thresholding: To move into actual clinics, researchers need to define specific "uncertainty thresholds" that would trigger a manual review by an ophthalmologist.

Overall, the paper demonstrates that by refining the mathematical "loss" of a model to include a more principled entropy term, we can build AI tools that are not just accurate, but also "honest" about their own limitations.

Summary updated

Abstract

We propose a novel conditional entropy function as a basis for quantifying predictive uncertainty in Evidential Deep Learning (EDL) for glaucoma detection from retinal fundus images. Using the EyePACS-AIROGS-light-V2 and RIM-ONE-DL datasets for validation, we found that our proposed EDL model regularized by conditional entropy function produced uncertainty estimates with substantially lower calibration errors than Deep Ensembles, MC Dropout, post-hoc calibration and the conventional EDL framework based on Dempster uncertainty. To further probe our models' interpretability, we analyzed Grad-CAM heatmaps using a focus index representing spatial concentration. Compared with the other uncertainty quantification methods, EDL models exhibited greater separation between the index distributions of correctly and incorrectly classified fundus images. In particular, false negatives were associated with localized Grad-CAM activations that were displaced from the optic disc, consistent with its established clinical importance in glaucoma assessment. Overall, our findings suggest that our proposed EDL framework for glaucoma detection provides not only enhanced uncertainty calibration but also admits a more physiologically consistent interpretability.
BibTeX
@misc{tan2026evidential,
  author = {Hai Siong Tan and Kuancheng Wang},
  title = {{Evidential Deep Learning with conditional entropy for glaucoma detection}},
  year = {2026},
  eprint = {2611.13513},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.13513},
}
Figure