Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry

Moein Heidari, Junbo Rao, Yudan Chen, Yasamin Medghalchi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal, Ilker HacihalilogluarXiv 2026

In clinical ultrasound, "biometry"—the process of measuring anatomical structures—is the bread and butter of diagnostic imaging. Whether it’s measuring a fetal head circumference or the diameter of a heart valve, clinicians rely on placing "calipers" at specific landmarks. However, manual placement is tedious and prone to inter-operator variability.

A new paper, "Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry," introduces Kev-Bio, a vision-language framework that transforms these measurements from a manual chore into a sophisticated spatial decision-making task.

TL;DR

Kev-Bio is a vision-language model that localizes ultrasound landmarks by matching clinical measurement questions to dense image features. By treating every pixel as a candidate response and modeling spatial probability, it provides a unified, flexible framework that outperforms specialized models across diverse cardiac and prenatal tasks.

What Problem Does This Paper Address?

Automating ultrasound biometry is notoriously difficult. Ultrasound images are noisy (speckle noise), prone to shadowing, and vary wildly depending on probe orientation.

Existing AI solutions typically fall into two camps:

  1. Specialized Models: These use fixed "prediction heads" for specific tasks. If you want to measure something new, you often need a new model or a new head.
  2. Direct Regression: Some models try to predict $(x, y)$ coordinates directly. However, this "black box" approach doesn't account for spatial ambiguity—it can't tell you if it's "unsure" between two similar-looking structures.

The authors aim to create a unified framework that can handle any measurement task via text instructions while explicitly modeling the likelihood of every pixel being a landmark.

Methods

Kev-Bio is inspired by "System One" decision models, which prioritize fast, intuitive pattern matching over slow, autoregressive text generation.

The Architecture

The model combines three heavy-hitting visual encoders to create a "Pixel Neck" feature map:

  • Qwen3.5: Provides language-aligned visual features.
  • USFM (Ultrasound Foundation Model): Contributes domain-specific ultrasound representations.
  • DINOv2: Offers high-resolution, multi-level spatial details.
Overview of the Kev-Bio architecture showing the fusion of visual encoders and the language-conditioned pixel pointer.

The "Pixel Pointer"

Instead of asking the model to "write" the coordinates, the researchers use the internal "decision states" of the Large Language Model (LLM). When the model sees a prompt like "Place the four caliper points of the head circumference," it generates a query vector for each point. These vectors are compared against the dense image feature map using a dot product. The result is a spatial probability map (a heatmap) for every landmark.

The final coordinates are derived using a differentiable soft-argmax operation, allowing the entire system to be trained end-to-end with a combination of landmark, heatmap, and geometric (measurement) losses.

Datasets

The model was evaluated on the FU/GU Biometry 2026 benchmark (from the MICCAI 2026 FoundUS challenge). This is a challenging, highly imbalanced dataset featuring:

  • 6,743 labeled images across 9 anatomical views.
  • 60 unique landmarks and 29 clinical measurements (distances, circumferences, and angles).
  • Domains spanning cardiac, prenatal, and intrapartum imaging.
Summary of the FU/GU Biometry 2026 dataset across cardiac, prenatal, and intrapartum tasks.

Key Insights and Ideas

  • Language as a Guide: By using text instructions, the model can adapt its spatial attention. The same image can produce different landmarks depending on whether you ask for "ventricular length" or "atrial width."
  • Uncertainty is a Feature: Because the model produces a probability map rather than a single point, the entropy of that map serves as an uncertainty score. The authors found that the 10% most "uncertain" predictions captured 40% of the actual localization errors, providing a built-in "check engine light" for clinicians.
  • Ablation Success: The biggest performance drop occurred when the "pixel pointer" was removed in favor of direct coordinate regression. This confirms that matching text queries to dense spatial features is fundamentally superior for this domain.

Key Results

Kev-Bio set a new state-of-the-art on the benchmark, outperforming both general-purpose landmark detectors and specialized challenge baselines.

  • Mean Radial Error (MRE): 22.50 pixels (the best baseline, CAMS, achieved 23.88).
  • Mean Absolute Error (MAE) for measurements: 15.38 (vs. 17.47 for the best baseline).
  • Versatility: It achieved the best landmark localization on 8 out of 9 views, showing remarkable consistency across different organs and clinical domains.
Comparison of Kev-Bio against general and challenge baselines on the FU/GU Biometry 2026 dataset.

Limitations and Future Work

While Kev-Bio is a significant step forward, the authors note a few hurdles:

  • Generalization: The model was tested on predefined measurements. Its ability to handle "zero-shot" instructions for entirely unseen anatomical structures remains to be explored.
  • Efficiency: Combining three large encoders (Qwen, USFM, DINOv2) is computationally expensive, which might limit real-time deployment on portable ultrasound devices.
  • Calibration: While entropy helps identify errors, formal uncertainty calibration is still needed to ensure the probability maps are statistically reliable for clinical decision-making.

For those interested in the implementation, the code and models are available on GitHub.

Summary updated

Abstract

**Purpose:** Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. **Methods:** We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. **Results:** On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. **Conclusion:** These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.
BibTeX
@misc{heidari2026every,
  author = {Moein Heidari and Junbo Rao and Yudan Chen and Yasamin Medghalchi and River Jiang and Wenjin Chen and David J. Foran and Jasmine Grewal and Ilker Hacihaliloglu},
  title = {{Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry}},
  year = {2026},
  eprint = {2611.03360},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.03360},
}
Figure