Evaluation of VDT-Induced Visual Fatigue by Automatic Detection of Blink Features

Zhijie Yin, Bing Liu, Dongmei Hao, Lin Yang, Yongkang Feng2022

TL;DR

This paper introduces an automated method to track visual fatigue during prolonged VDT use by analyzing blink patterns. By extracting features like blink rate, duration, and interval, the study demonstrates a clear correlation between these objective blink metrics and the progression of self-reported visual fatigue. This offers a promising, non-intrusive approach for monitoring eye strain in real-world scenarios.

What Problem Does This Paper Address?

Modern life increasingly involves prolonged interaction with Visual Display Terminals (VDTs) like computers and smartphones, leading to a rise in visual fatigue. This condition manifests as discomforting symptoms such as blurred vision, dry eyes, and headaches, impacting productivity and well-being. While subjective questionnaires exist, they are prone to individual bias and cannot continuously monitor fatigue. Objective methods, such as those using electroencephalography (EEG) or electrooculography (EOG), often require cumbersome equipment or electrodes that can themselves induce fatigue. Therefore, there's a need for a convenient, objective, and continuous method to assess VDT-induced visual fatigue. This paper aims to fill this gap by leveraging automatic blink feature analysis from facial video recordings.

Methods

The core of this research lies in an automated blink detection and feature extraction pipeline.

  • Blink Detection: The system first detects faces and then uses 68 facial landmarks to locate the eyes. Blinking is identified by monitoring the Eye Aspect Ratio (EAR), a measure of eye opening. A blink is registered when the EAR drops below a threshold (0.2) and then rises above it again.
  • Incomplete Blink Detection: To differentiate complete from incomplete blinks, the researchers developed a subject-specific threshold. They calculated the vertical distance between the upper eyelid and the eye corner (Duc) during blinks. The median of the maximum Duc values (maxDuc) for complete blinks in the initial minutes of the experiment served as a reference (mmDuc). Blinks with a maxDuc less than 75% of mmDuc were classified as incomplete. This approach accounts for individual differences in eyelid morphology.
  • Feature Extraction: Seven blink features were extracted over 30-minute intervals:
  • Blink Number (BN): Total blinks.
  • Mean Blink Interval (Mean_BI): Average time between consecutive blinks.
  • Mean Blink Duration (Mean_BD): Average duration of a blink.
  • Group Blink Number (GBN): Number of blinks occurring within a short interval (less than 1 second), indicating a potential need for more frequent lubrication.
  • Mean Group Blink Interval (Mean_GBI): Average time between these "group blinks."
    • Incomplete Blink Number (IBN): Number of incomplete blinks.
  • Mean Incomplete Blink Interval (Mean_IBI): Average time between incomplete blinks.
  • Statistical Analysis: The study employed Wilcoxon signed-rank tests for questionnaire scores and Friedman's test for blink features to assess statistical significance (p < 0.05).

Datasets

The study utilized a dataset of 23 participants (12 women, 11 men) aged 23-28, who were regular VDT users. Face videos were recorded during a 120-minute VDT task involving watching a documentary. Approximately 3000 blinks, including 500 incomplete blinks, were manually labeled in the first 10 minutes for training and validation of the incomplete blink detection algorithm. No pre-existing public datasets were used for training or evaluation; the data was collected specifically for this study.

Key Insights and Ideas

  • Subject-Specific Incomplete Blink Detection: The use of a subject-specific threshold (mmDuc) for identifying incomplete blinks is a crucial innovation. It addresses the inherent variability in eyelid structure and movement across individuals, making the detection more robust than a universal threshold.
  • Blink Features as Objective Fatigue Indicators: The study convincingly demonstrates that changes in blink patterns are not random but directly correlate with increasing visual fatigue. This provides a powerful, non-intrusive objective measure.
  • Long-Term VDT Task is Crucial: The paper highlights the importance of a long-term VDT task (120 minutes) to observe the progression of fatigue, which might not be evident in shorter studies.
  • Group Blinks as a Fatigue Signal: The increase in group blinks and decrease in their interval suggests that individuals are attempting to compensate for insufficient tear film lubrication by blinking more frequently in rapid succession.

Key Results

  • Subjective Fatigue Increases: Questionnaire scores showed a significant increase over the 120-minute VDT session, confirming the development of visual fatigue.
  • Objective Blink Changes:
    • Blink Number (BN) and Mean Blink Duration (Mean_BD) significantly increased over time.
  • Mean Blink Interval (Mean_BI) and Mean Group Blink Interval (Mean_GBI) significantly decreased over time.
  • Group Blink Number (GBN) also significantly increased.
  • Interestingly, Incomplete Blink Number (IBN) showed no significant difference in the first 90 minutes but decreased in the last 30 minutes, while Mean_IBI increased. This suggests participants may have consciously tried to complete their blinks more effectively as fatigue set in, rather than increasing incomplete blinks.

Limitations and Future Work

  • Image Quality and Accuracy: The authors acknowledge that improving image quality and the accuracy of incomplete blink detection remains an area for future work.
  • Limited Scope of Features: While blink features are powerful, future research could explore other eye movement parameters (e.g., saccades, fixation duration) for a more comprehensive assessment of visual fatigue.
  • Elderly and Other Populations: The study focused on young subjects. Future work could investigate how these findings apply to older adults, whose visual fatigue might be influenced by age-related eye changes, or to specific occupational groups like office workers.
  • Influence of Other Factors: The paper suggests investigating the impact of dry eye and mental fatigue on visual fatigue, as these could be confounding factors.