NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Evaluation of the Success Rate of a 3D-Printed Videolaryngoscope Model in Simulation

Andres Duque-Estevez, Germán Franco, Laura Peña-Blanco, Natalia Restrepo-Patiño, Juan Gutiérrez-NavarroCureus 2026

TL;DR

This paper introduces the "Printoscope," a low-cost, 3D-printed videolaryngoscope designed to improve accessibility for airway management training. In a simulation study with anesthesiology residents, the Printoscope achieved a high first-attempt success rate of 90.91%, demonstrating its potential as an effective and affordable tool for medical education, especially in resource-limited settings.

What Problem Does This Paper Address?

Orotracheal intubation (OTI) is a critical procedure for securing a patient's airway, but its success heavily relies on operator experience and the tools available. While videolaryngoscopy significantly improves success rates and shortens the learning curve compared to traditional direct laryngoscopy, its high cost (ranging from $800 to $12,000) presents a major barrier to widespread adoption and training, particularly in resource-constrained environments. This limits the ability of many institutions to provide adequate training in this essential skill.

Methods

The researchers developed a 3D-printed videolaryngoscope model, dubbed the "Printoscope," through an iterative design process focused on optimizing glottic visualization. The final design features a blade with a 62° angle and a camera positioned at a 50° angle, intended to enhance visualization of the vocal cords and facilitate endotracheal tube placement. This 3D-printed device was integrated with a low-cost, industrial borescope (IP67 rated, with integrated LED illumination and a 3-8 cm focal range) that connects to any smartphone or tablet for real-time imaging.

A simulation-based study was conducted with 22 anesthesiology residents (post-graduate years 1-3) at a Colombian institution. Participants performed standard manikin intubations using the Printoscope. Key performance metrics evaluated included:

  • Intubation time: The duration from grasping the laryngoscope to endotracheal cuff inflation.
  • Cormack-Lehane grade: A classification system for glottic visualization (Grade I being the best).
  • Percentage of Glottic Opening (POGO) score: Quantifying the visible portion of the glottis (0-100%).
  • First-attempt success rate: Whether intubation was successful on the initial attempt.
  • Usability and ergonomics: Assessed via a subjective evaluation form.

Datasets

Not discussed in the paper. The study utilized a manikin for simulation-based training and collected performance data from 22 anesthesiology residents.

Key Insights and Ideas

  • Democratizing Advanced Airway Training: The most significant insight is the potential of 3D printing to create highly functional medical devices at a fraction of the cost of commercial alternatives. This opens doors for advanced training in resource-limited settings.
  • Optimized Design for Visualization: The specific angles chosen for the blade (62°) and camera (50°) were crucial for achieving excellent glottic visualization, placing the vocal cords in the upper third of the screen, which is key for successful intubation.
  • Cost-Effectiveness is Key: The Printoscope's estimated cost of approximately $16 per unit is a game-changer compared to commercial videolaryngoscopes, making it a scalable solution for widespread training.
  • High Usability and Ergonomics: Despite being a novel, low-cost device, the Printoscope received top ratings for usability and ergonomics, indicating it's not just cheap but also practical for users.

Key Results

  • First-Attempt Success Rate: 90.91% (20 out of 22 residents) successfully intubated on their first attempt.
  • Intubation Time: The average intubation time was 28.6 seconds (range: 7.7-153 seconds), with faster times observed in more experienced residents.
  • Glottic Visualization:
    • Median POGO score was 100%.
  • 90.9% (20 out of 22) achieved a Cormack-Lehane Grade I view.
  • Usability and Ergonomics: Both received a perfect score of 5 out of 5.
  • Comparison to Commercial Devices: The success rate closely approached that reported for commercial videolaryngoscopes in simulation studies.
  • Comparison to Other 3D-Printed Models: The Printoscope outperformed the AirAngel model, which had a significantly lower success rate (47.80%), potentially due to the AirAngel's more extreme blade angulation.

Limitations and Future Work

The authors acknowledge several limitations:

  • Simulation-Based Only: The study was conducted solely on manikins, and results may not directly translate to real-world patient care.
  • Specific Learner Population: Participants were all anesthesiology residents, whose experience might differ from learners in other medical specialties.
  • Subjective Evaluation Instrument: The usability and ergonomics were assessed using a non-formally validated instrument.
  • Pilot Nature: The study was exploratory and did not include a comparator group.

Future work planned includes:

  • Clinical Validation: Evaluating the Printoscope's performance in actual patient care.
  • Multicenter Evaluation: Expanding the study to multiple institutions to assess its broader applicability and gather more diverse data.
  • Diverse Learner Populations: Testing the device with learners from various medical specialties.

Summary updated

BibTeX
@inproceedings{duqueestevez2026evaluation,
  author = {Andres Duque-Estevez and Germán Franco and Laura Peña-Blanco and Natalia Restrepo-Patiño and Juan Gutiérrez-Navarro},
  title = {{Evaluation of the Success Rate of a 3D-Printed Videolaryngoscope Model in Simulation}},
  booktitle = {Cureus},
  year = {2026},
  doi = {10.7759/cureus.102278},
}

Loading related content...

Figure