Evaluation of the ex vivo liver viability using a nuclear magnetic resonance relaxation time-based assay in a porcine machine perfusion model

Qing Ouyang, Guohai Liang, Xiaoyu Tan, Xiran He, Lin Zhang, Weijian Kuang, Jian‐Xiong Chen, Shaoping Wang, Mingju Liang, Feng HuoScientific 2021 · DOI

Abstract: There is a dearth of effective parameters for selecting potentially transplantable liver grafts from expanded-criteria donors. In this study, we used a nuclear magnetic resonance (NMR) relaxation analyzer-based assay to assess the viability of ex vivo livers obtained via porcine donation after circulatory death (DCD). Ex situ normothermic machine perfusion (NMP) was utilized as a platform for viability test of porcine DCD donor livers. A liver-targeted contrast agent, gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), was injected into the perfusate during NMP, and the dynamic biliary excretion of the Gd-EOB-DTPA was monitored by measuring the longitudinal relaxation time (T1). The longitudinal relaxation rate (R1) of the bile served as a parameter. The delay of increase in biliary R1 during early stage of NMP indicated the impaired function of liver grafts in both warm and cold ischemia injury, which was correlated with the change of alanine aminotransferase. The preservative superiority in cold ischemia of dual hypothermic oxygenated machine perfusion could also be verified by assessing biliary R1 and other biochemical parameters. This study allows for the dynamic assessment of the viability of porcine DCD donor livers by combined usage of ex situ NMP and NMR relaxation time based assay, which lays a foundation for further clinical application.

Introduction

The global shortage of donor livers has necessitated the use of "expanded-criteria donor" (ECD) organs, including those from donors after circulatory death (DCD). These grafts are particularly susceptible to ischemia-reperfusion injury, leading to higher risks of primary graft dysfunction and biliary complications. While ex situ normothermic machine perfusion (NMP) provides a platform for assessing liver viability prior to transplantation, current markers like lactate clearance or pH are often non-specific. There is a critical need for a dynamic, functional assay that can accurately reflect the liver's metabolic and excretory capacity in real-time.

Methods

This study utilized a porcine model (n=29 Bama miniature pigs) to evaluate a novel nuclear magnetic resonance (NMR)-based viability assay. Livers were subjected to varying warm ischemia times (WIT: 0, 30, or 60 minutes) to simulate different levels of DCD injury. Following procurement, livers were placed on an NMP circuit at 37°C.

A liver-specific contrast agent, gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), was injected into the perfusate. This agent is selectively taken up by hepatocytes and excreted into the bile. Bile samples were collected every 30 minutes and analyzed using a compact 0.5T benchtop NMR analyzer to measure the longitudinal relaxation time (T1). The relaxation rate (R1 = 1/T1) served as a quantitative proxy for the concentration of the contrast agent in the bile.

Experimental setup and methodology overview. (A) The ex situ NMP circuit. (B) Linear correlation between relaxation rate (R1) and Gd-EOB-DTPA concentration. (C) Representative T1 maps of bile samples over time. (D) Experimental timelines for injury and preservation groups.

Results

The study established a near-perfect linear correlation between the biliary R1 and the concentration of Gd-EOB-DTPA, enabling precise quantification of hepatocyte excretory function. Functional assessment via the NMR assay proved significantly more sensitive than traditional histology. While H&E staining showed minimal structural differences between WIT groups, the biliary R1 clearly distinguished the levels of functional injury.

In healthy livers (0 min WIT), R1 reached approximately 22.4 s⁻¹ one hour post-injection. In contrast, severely injured livers (60 min WIT) showed a nearly flat response, with R1 remaining at ~1.3 s⁻¹ (P < 0.01). Furthermore, R1 at the 1-hour mark showed a strong negative correlation with alanine aminotransferase (ALT) levels (r = -0.854, P < 0.001), a standard clinical marker of hepatocellular damage.

The assay also successfully validated the benefits of Dual Hypothermic Oxygenated Machine Perfusion (DHOPE). Livers preserved with DHOPE showed significantly higher biliary R1 rates during subsequent NMP compared to those kept in standard static cold storage (SCS), reaching ~32.89 s⁻¹ versus ~2.36 s⁻¹ at the 2-hour mark (P < 0.01). Additionally, higher R1 values correlated with improved biliary pH and bicarbonate levels, suggesting that hepatocyte excretion function is a reliable indicator of overall biliary tract health.

Discussion and Conclusion

The use of a compact benchtop NMR analyzer offers a practical solution for real-time functional monitoring during NMP, bypassing the logistical and technical challenges of integrating standard MRI machines with perfusion hardware. This "functional stress test" provides a dynamic measure of hepatocyte work, capturing impairments that precede visible structural damage.

While these results are promising, several steps remain for clinical translation. Future research must define definitive R1 thresholds for transplantability and correlate these findings with post-transplant outcomes in human recipients. Additionally, integrating the NMR sensor directly into the perfusion circuit could allow for fully automated, continuous monitoring. In conclusion, this NMR-based assay provides a sensitive and dynamic method for assessing the viability of DCD donor livers, offering a potential new standard for graft selection in clinical transplantation.

Summary updated

Abstract

There is a dearth of effective parameters for selecting potentially transplantable liver grafts from expanded-criteria donors. In this study, we used a nuclear magnetic resonance (NMR) relaxation analyzer-based assay to assess the viability of ex vivo livers obtained via porcine donation after circulatory death (DCD). Ex situ normothermic machine perfusion (NMP) was utilized as a platform for viability test of porcine DCD donor livers. A liver-targeted contrast agent, gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), was injected into the perfusate during NMP, and the dynamic biliary excretion of the Gd-EOB-DTPA was monitored by measuring the longitudinal relaxation time (T1). The longitudinal relaxation rate (R1) of the bile was served as a parameter. The delay of increase in biliary R1 during early stage of NMP indicated the impaired function of liver grafts in both warm and cold ischemia injury, which was correlated with the change of alanine aminotransferase. The preservative superiority in cold ischemia of dual hypothermic oxygenated machine perfusion could also be verified by assessing biliary R1 and other biochemical parameters. This study allows for the dynamic assessment of the viability of porcine DCD donor livers by combined usage of ex situ NMP and NMR relaxation time based assay, which lays a foundation for further clinical application.
BibTeX
@inproceedings{ouyang2021evaluation,
  author = {Qing Ouyang and Guohai Liang and Xiaoyu Tan and Xiran He and Lin Zhang and Weijian Kuang and Jian‐Xiong Chen and Shaoping Wang and Mingju Liang and Feng Huo},
  title = {{Evaluation of the ex vivo liver viability using a nuclear magnetic resonance relaxation time-based assay in a porcine machine perfusion model}},
  booktitle = {Scientific},
  year = {2021},
  doi = {10.1038/s41598-021-83202-3},
}
Figure