Evaluation of p-GaN HEMTs degradation under high temperatures forward and reverse gate bias stress
Abstract
Abstract In this study, the degradation behavior and physical mechanism of the p-GaN HEMT devices under high-temperature gate bias (HTGB) with +5 V and −5 V were investigated. The DC characteristics show that the device after forward HTGB stress exhibits an obvious negative threshold voltage ( V th ) shift, while the device after reverse HTGB exhibits a negligible shift. The following explanations could be given for the deterioration mechanism: a portion of the two-dimensional hole gas (2DHG) accumulated in the p-GaN layer at the p-GaN/AlGaN interface under long-term forward bias may fill the trap in the AlGaN layer through the tunneling effect. In addition, the drain-source on-resistance of the device had increased after +5 V HTGB stress, and a distinct decrease of accumulated capacitance was observed in the C g - V g curve. It indicates a degradation of the gate quality of the device after applying a forward-biased HTGB stress.
BibTeX
@article{jiang2023evaluation,
author = {Kun Jiang and Jing Deng and Yiqiang Ni and Jun Liu and Xin Liu and Zhiyuan He and Liang He},
title = {{Evaluation of p-GaN HEMTs degradation under high temperatures forward and reverse gate bias stress}},
journal = {Journal of Physics Conference Series},
year = {2023},
doi = {10.1088/1742-6596/2645/1/012016},
}Ask Althea to put this paper to the test.