Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c)

Xun Chen, Tian Han, Feng Zhao, Huamao Miao, Xiaoying Wang, Xingtao ZhouJournal of Ophthalmology 2019 · DOI

TL;DR

This study investigates how the size of "disk halos" (visual disturbances around lights) changes after implantation of a specific type of intraocular lens (ICL V4c) designed for myopia correction. The findings show that disk halos significantly decrease in size over time, and importantly, patients with naturally smaller pupils tend to experience smaller halos post-surgery, suggesting pupil size is a key factor in visual quality after this procedure.

What Problem Does This Paper Address?

Refractive surgeries, including the implantation of intraocular lenses (IOLs) like the Visian Implantable Collamer Lens (ICL), aim to correct vision and improve visual quality. However, a common side effect, particularly noticeable at night or in low light conditions, is the perception of "disk halos" or glare around light sources. These halos can significantly impact daily life, especially for activities like driving. While the ICL V4c, a newer version with a central hole designed to improve aqueous humor flow and eliminate the need for a peripheral iridotomy, has shown excellent refractive results, the issue of postoperative halos persists for some patients. This paper addresses the need to quantify changes in disk halo size after ICL V4c implantation and to understand what patient-specific factors, particularly related to the dynamic pupillary light response, might influence their occurrence and severity.

Methods

This prospective study enrolled 42 patients undergoing ICL V4c implantation for myopia correction. The researchers meticulously measured disk halo size and various parameters of the pupillary light response (e.g., contraction/dilation amplitude, latency, duration, and velocity, along with initial, maximum, minimum, and average pupil diameters) using a monocular dynamic pupillometry system. These measurements were taken preoperatively and at three postoperative time points: 1 week, 1 month, and 3 months. The study employed a standardized protocol involving a specific light source luminance and darkness adaptation period to ensure consistent and repeatable measurements. Statistical analyses, including repeated-measures ANOVA and correlation analyses, were used to evaluate temporal changes and relationships between variables.

Datasets

Not discussed in the paper. The study utilized measurements from the enrolled patients themselves.

Key Insights and Ideas

  • Halo Reduction is Real: The study provides quantitative evidence that disk halos, a common concern after ICL implantation, significantly decrease in size in the months following surgery. This is reassuring for patients considering or having undergone the procedure.
  • Pupil Size Matters: A crucial finding is the strong correlation between smaller pupil sizes during the dynamic pupillary light response and smaller disk halos post-ICL V4c implantation. This suggests that a patient's inherent pupillary behavior is a significant predictor of their visual quality experience.
  • Dynamic Pupillary Response is Key: The paper highlights the importance of not just static pupil size, but the dynamic changes in pupil size in response to light. While some pupillary response parameters changed post-surgery, the correlation with halo size was most pronounced with the actual pupil diameters achieved during the response.
  • ICL V4c Design Benefits: The central hole in the ICL V4c, which facilitates aqueous humor flow, may contribute to the observed reduction in halos, potentially by influencing the optical path or reducing anterior chamber dynamics that could exacerbate glare.

Key Results

  • Disk halo size showed no significant difference at 1 week postoperatively but decreased significantly at 1 month (P < 0.001) and 3 months (P < 0.001) compared to preoperative values.
  • Pupillary response parameters like contraction amplitude and velocity, and dilation velocity, decreased significantly at all postoperative time points (all P < 0.001).
  • Minimum pupil diameter increased significantly at 1 week and 1 month postoperatively but returned to baseline by 3 months. Maximum pupil diameter significantly decreased at 3 months postoperatively (P = 0.01).
  • Disk halo size at 3 months postoperatively was significantly correlated with initial (r=0.446, P = 0.003), maximum (r=0.483, P = 0.001), minimum (r=0.425, P = 0.005), and average pupil diameters (r=0.474, P = 0.002).

Limitations and Future Work

The authors acknowledge that this study was limited by not including subjective questionnaires about halo phenomena, which would provide a more complete picture of the patient's visual experience. Future work could involve longer-term follow-up studies to track halo size and pupillary response changes beyond 3 months. Additionally, further research could explore the precise mechanisms by which pupil size influences halo perception after ICL implantation and investigate strategies to optimize outcomes for patients with naturally larger pupils.

Summary updated

Abstract

After ICL V4c implantation, disk halo size was reduced in the short term. Patients with smaller pupil sizes during pupillary response to light experienced smaller halos after ICL V4c implantation.
BibTeX
@article{chen2019evaluation,
  author = {Xun Chen and Tian Han and Feng Zhao and Huamao Miao and Xiaoying Wang and Xingtao Zhou},
  title = {{Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c)}},
  journal = {Journal of Ophthalmology},
  year = {2019},
  doi = {10.1155/2019/7174913},
}
Figure