Evaluation of Aviation AC Arc Fault Damage to Electrical Wiring Interconnection System Based on MHD Simulation
Lists
Only you see this
Abstract
Electrical fire hazards due to arc faults are critical to the safety of more-electric aircraft (MEA)/all-electric aircraft (AEA). In this study, the damage behavior to the electrical wiring interconnection systems (EWIS) caused by AC arc faults are carried out. To this end, an axisymmetric model for the series arc fault in a single wire is implemented using the field-circuit coupled magnetohydrodynamic (MHD) method. In order to emulate the wet arc fault between two phases, a 2D model is developed for a wire bundle with two pre-damaged wires. In specific, the thermal field, flow field, and electromagnetic field are numerically coupled for the computation of the distribution of the temperature. The results reveal that the high temperature caused by arc fault leads to heavy damage to the faulty wire and an adjacent one.
BibTeX
@article{liu2025evaluation,
author = {Peilin Liu and Youpeng Huangfu and Shuhong Wang},
title = {{Evaluation of Aviation AC Arc Fault Damage to Electrical Wiring Interconnection System Based on MHD Simulation}},
journal = {IEEE Transactions on Magnetics},
year = {2025},
doi = {10.1109/tmag.2025.3628848},
}Loading related content...