Evaluation by a Machine Learning System of Two Preparations for Small Bowel Capsule Endoscopy: The BUBS (Burst Unpleasant Bubbles with Simethicone) Study

Charles Houdeville, Romain Leenhardt, Marc Souchaud, Guillaume Velut, Nicolas Carbonell, Isabelle Nion–Larmurier, Alexandre Nuzzo, Aymeric Histace, Philippe Marteau, Xavier DrayJournal of Clinical Medicine 2022 · DOI

TL;DR

This study leverages machine learning (ML) to objectively quantify bubble presence in small bowel capsule endoscopy (SB CE) videos. It demonstrates that adding simethicone to standard PEG bowel preparations significantly reduces bubble abundance, particularly in the challenging distal small bowel, without negatively impacting diagnostic yield or transit times.

What Problem Does This Paper Address?

Small bowel capsule endoscopy (SB CE) is a crucial tool for diagnosing conditions like obscure gastrointestinal bleeding (OGIB). However, the quality of the images captured can be severely hampered by factors like bubbles, chyme, and food residue, which obscure the mucosal lining. Traditionally, assessing the cleanliness of these videos relies on human readers, but this method suffers from poor inter- and intra-observer reproducibility. This makes it difficult to reliably compare different preparation methods designed to improve visualization. Specifically, the effectiveness of anti-foaming agents like simethicone in reducing bubble presence and improving overall image quality has been a subject of debate, with previous studies showing mixed results due to subjective assessments.

Methods

The researchers employed a validated, AI-driven approach to analyze SB CE videos. The core of their method involved a machine learning algorithm based on a Grey-Level Co-occurrence Matrix (GLCM). This algorithm analyzes textural features within each video frame to quantify the abundance of bubbles. Specifically, it classifies frames as having "abundant" bubbles (covering ≥10% of the image surface) or "scarce" bubbles (<10%).

To assess overall cleanliness, they also utilized a Red over Green (R/G) ratio, often referred to as the "SB-CAC score." This metric leverages pixel color intensity to differentiate between mucosal visualization (high red intensity) and the presence of debris (high green intensity), aiming for a ratio >1.6 to indicate adequate cleansing.

The study design was a retrospective, monocentric comparison of two groups of outpatients with OGIB. One group received a standard polyethylene glycol (PEG) preparation (SMT- group), while the other received the same PEG preparation with the addition of simethicone (SMT+ group). The primary outcome was the proportion of frames with abundant bubbles. Secondary outcomes included bubble abundance in different quartiles of the video, overall SB cleanliness, diagnostic yield (DY), and capsule transit times.

Datasets

The study analyzed 105 third-generation SB CE recordings from outpatients with OGIB. These recordings were collected over two distinct periods:

  • SMT- Group: 48 recordings from November 1, 2018, to October 31, 2019, using MOVIPREP® (PEG and ascorbate).
  • SMT+ Group: 57 recordings from December 1, 2019, to November 30, 2020, using XIMEPEG® (PEG with citric acid and simethicone).

A one-month washout period was implemented between the two study periods to minimize potential carry-over effects. The data was pseudonymized, and the analysis was performed using the Augmented Endoscopy platform.

Key Insights and Ideas

  • Objective Bubble Quantification is Key: The study highlights the limitations of subjective human assessment for bubble presence and cleanliness. The ML-based GLCM algorithm provides a reproducible and objective measure, which is crucial for comparing preparation strategies.
  • Simethicone's Targeted Impact: While simethicone didn't dramatically improve overall cleanliness scores (R/G ratio), it demonstrably reduced the amount of bubbles, particularly in the later stages of the small bowel (distal ileum). This suggests its primary benefit is in mitigating bubble formation where visualization is often most challenging.
  • No Compromise on Diagnostic Yield: A critical finding is that the improved bubble reduction with simethicone did not come at the cost of diagnostic yield, transit time, or completion rate. This is important for clinical adoption, as any preparation strategy must maintain or improve diagnostic efficacy.
  • AI as a Powerful Research Tool: The study underscores the potential of AI and ML not just for clinical applications but also as powerful tools for research, enabling more precise and reproducible evaluation of interventions.

Key Results

  • Reduced Bubble Abundance: The SMT+ group (with simethicone) showed a significantly lower proportion of frames with abundant bubbles compared to the SMT- group (p = 0.04).
  • Marked Effect in Distal SB: This reduction was particularly pronounced in the fourth quartile of the small bowel video, with a significantly lower proportion of "abundant in bubbles" frames in the SMT+ group (20.6%) versus the SMT- group (30.5%) (p = 0.02).
  • No Significant Difference in Cleanliness: Despite reduced bubbles, the overall cleanliness (R/G ratio > 1.6) did not differ significantly between the two groups (p = 0.26).
  • No Impact on Diagnostic Yield: The diagnostic yield (P1 or P2 lesions) was similar between the SMT- (41.7%) and SMT+ (42.1%) groups (p = 0.96).
  • Transit Times and Completion: Gastric and small bowel transit times, as well as capsule completion rates, were comparable between the groups, with no statistically significant differences.

Limitations and Future Work

  • Retrospective and Monocentric Design: The study's retrospective nature and single-center origin limit generalizability.
  • Limited Sample Size: While 105 videos were analyzed, the authors acknowledge that this number might limit the statistical power for secondary endpoints, particularly for overall cleanliness and diagnostic yield.
  • Preparation Differences: Although the PEG base was similar, the two preparations (MOVIPREP® and XIMEPEG®) had slight differences in active substances (ascorbic acid vs. citric acid), which could theoretically influence results, though the authors argue these are minor.
  • Future Directions: The authors strongly advocate for randomized controlled trials that utilize computer algorithms for bubble assessment (rather than human readers) to further investigate the role of simethicone. They also suggest exploring its use in patients with Crohn's disease, where terminal ileum visualization is critical. Further research could also focus on optimizing ML algorithms for even more nuanced analysis of SB CE videos.

Summary updated

Abstract

Background: Bubbles often mask the mucosa during capsule endoscopy (CE). Clinical scores assessing the cleanliness and the amount of bubbles in the small bowel (SB) are poorly reproducible unlike machine learning (ML) solutions. We aimed to measure the amount of bubbles with ML algorithms in SB CE recordings, and compare two polyethylene glycol (PEG)-based preparations, with and without simethicone, in patients with obscure gastro-intestinal bleeding (OGIB). Patients & Methods: All consecutive outpatients with OGIB from a tertiary care center received a PEG-based preparation, without or with simethicone, in two different periods. The primary outcome was a difference in the proportions (%) of frames with abundant bubbles (>10%) along the full-length video sequences between the two periods. SB CE recordings were analyzed by a validated computed algorithm based on a grey-level of co-occurrence matrix (GLCM), to assess the abundance of bubbles in each frame. Results: In total, 105 third generation SB CE recordings were analyzed (48 without simethicone and 57 with simethicone-added preparations). A significant association was shown between the use of a simethicone-added preparation and a lower abundance of bubbles along the SB (p = 0.04). A significantly lower proportion of “abundant in bubbles” frames was observed in the fourth quartile (30.5% vs. 20.6%, p = 0.02). There was no significant impact of the use of simethicone in terms of diagnostic yield, SB transit time and completion rate. Conclusion: An accurate and reproducible computed algorithm demonstrated significant decrease in the abundance of bubbles along SB CE recordings, with a marked effect in the last quartile, in patients for whom simethicone had been added in PEG-based preparations, compared to those without simethicone.
BibTeX
@article{houdeville2022evaluation,
  author = {Charles Houdeville and Romain Leenhardt and Marc Souchaud and Guillaume Velut and Nicolas Carbonell and Isabelle Nion–Larmurier and Alexandre Nuzzo and Aymeric Histace and Philippe Marteau and Xavier Dray},
  title = {{Evaluation by a Machine Learning System of Two Preparations for Small Bowel Capsule Endoscopy: The BUBS (Burst Unpleasant Bubbles with Simethicone) Study}},
  journal = {Journal of Clinical Medicine},
  year = {2022},
  doi = {10.3390/jcm11102822},
}
Figure