Evaluating the Reproducibility of Hemodynamic Force Analysis in Cardiac MRI Using the Bland-Altman Method and ICC
Abstract
Motivation: Hemodynamic forces (HDF) analysis is considered a new method for analyzing cardiac function with its advantages of early detection and non-invasive evaluation by magnifying mechanical abnormalities. It also has excellent potential for clinical application. Goal(s): This study aims to investigate the stability and reliability of the HDF analysis method. Approach: We calculated the intra- and inter-observer's Blan-Altman consistency analysis-related parameters and the Intraclass Correlation Coefficient (ICC). Results: The results showed excellent intra- and inter-observer consistency for all HDF variables, supporting the potential clinical application of this technique. Impact: This study demonstrates the reliability of HDF analysis, promoting its adoption for non-invasive assessment of cardiac function and potentially aiding in the early detection and management of cardiac pathologies.
BibTeX
@inproceedings{hu2025evaluating,
author = {Miao Hu and Ziwen Xu and Jing Qi and Xiuzheng Yue and Jianan Li and Tao Li and Kunlun He},
title = {{Evaluating the Reproducibility of Hemodynamic Force Analysis in Cardiac MRI Using the Bland-Altman Method and ICC}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2025},
doi = {10.58530/2025/4142},
}Ask Althea to put this paper to the test.